Disposable pipette extraction (DPX) of ethylenethiourea and analysis by gas chromatography coupled to mass spectrometry in urine samples of vineyard farmers
Authors:
- Jéssica Cristina Zoratto RomoliJRJéssica Cristina Zoratto Romoli
- Deborah Thais Palma ScanferlaDSDeborah Thais Palma Scanferla
- Raul Gomes AgueraRARaul Gomes Aguera
- Renata Sano LiniRLRenata Sano Lini
- Giseli Cristina PanteGPGiseli Cristina Pante
- Carlos Roberto BuenoCBCarlos Roberto Bueno
- Juliana Cristina CastroJCJuliana Cristina Castro
- Simone Aparecida Galerani MossiniSMSimone Aparecida Galerani Mossini
- Camila MarchioniCMCamila Marchioni
- Miguel MachinskiMMMiguel Machinski
- 20 August 2025
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (9) , 1-12
Abstract
Disposable pipette extraction (DPX) is a modern miniaturized solid phase extraction technique that can be applied for analysis of different analytes in biological samples. Ethylenethiourea (ETU), a specific biotransformation product of ethylenebisdithiocarbamates (EBDCs), has antithyroid activity. Thus, the aim of this study was to optimize for the first time the DPX extraction technique for quantification of ETU in urine through gas chromatography mass spectrometry (GC/MS), validate, and apply this methodology. The DPX parameters were evaluated with univariate analysis: sorption phases, sample pH, sample volumes, cleaning, and elution solvents. This methodology can be considered environmentally friendly; therefore, it complies with the principles of Green Chemistry, using low volumes of solvents, thus generating few chemical residues during the analyses. The DPX/GC–MS method developed showed linearity for concentrations ranging from 100 to 1000 µg L−1, with the coefficient of correlation (r) greater than 0.997 and the lack-of-fit test (p value) of 0.568 (p > 0.05), and the LOQ was 100 µg L−1. The intra-assay and inter-assay precision and accuracy showed acceptable values. Carryover was not observed according to acceptance criterion. It was found that there was a matrix effect (p < 0.001) (rotational type), which was solved using an external standard of ETU in water and in the urine biological matrix. Most were collected after 24 h of exposure to EBDCs, and the mean level of ETU was 4.07 µg g−1 creatinine. The DPX/GC–MS development method proved to be suitable for extraction and quantification of ETU in biological urine samples.Keywords
This publication has 31 references indexed in Scilit:
- Microplastics mixture exposure at environmentally relevant conditions induce oxidative stress and neurotoxicity in the wedge clam Donax trunculusChemosphere, 2020
- Sample preparation for large‐scale bioanalytical studies based on liquid chromatographic techniquesBiomedical Chromatography, 2017
- A new tropane alkaloid from the leaves of Erythroxylum subsessile isolated by pH‐zone‐refining counter‐current chromatographyJournal of Separation Science, 2016
- Target-driven self-assembly of stacking deoxyribonucleic acids for highly sensitive assay of proteinsAnalytica Chimica Acta, 2015
- Study of sample preparation for metabolomic profiling of human saliva by liquid chromatography–time of flight/mass spectrometryJournal of Chromatography A, 2012
- TET2 Inactivation Results in Pleiotropic Hematopoietic Abnormalities in Mouse and Is a Recurrent Event during Human LymphomagenesisCancer Cell, 2011
- Introduction to Modern Liquid Chromatography2009
- Cone voltage induced in‐source dissociation of glucuronides in electrospray and implications in biological analysesRapid Communications in Mass Spectrometry, 2003
- Characterisation of combinatorial libraries of mucin‐2 antigen peptides by high‐resolution mass spectrometryRapid Communications in Mass Spectrometry, 2002
- Toxicokinetics of p -tert-octylphenol in male Wistar ratsArchives of Toxicology, 1996