Deborah Thais Palma Scanferla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Deborah Thais Palma Scanferla has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Camila Marchioni
Department of Pathology, Federal University of Santa Catarina, St. Delfino Conti S/N, Florianopolis, SC, 88040-370, Brazil.
1 shared publication - Carlos Roberto Bueno
Department of Basic Health Science, State University of Maringá, Maringá, Brazil
1 shared publication - Giseli Cristina Pante
Department of Basic Health Science, State University of Maringá, Maringá, Brazil
1 shared publication - Juliana Cristina Castro
Department of Basic Health Science, State University of Maringá, Maringá, Brazil
1 shared publication - Jéssica Cristina Zoratto Romoli
Department of Basic Health Science, State University of Maringá, Maringá, Brazil
1 shared publication - Miguel Machinski Junior
Department of Basic Health Science, State University of Maringá, Maringá, Brazil
1 shared publication
Latest Publications
- 20 August 2025
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (9) , 1-12
Disposable pipette extraction (DPX) of ethylenethiourea and analysis by gas chromatography coupled to mass spectrometry in urine samples of vineyard farmers
Disposable pipette extraction (DPX) is a modern miniaturized solid phase extraction technique that can be applied for analysis of different analytes in biological samples. Ethylenethiourea (ETU), a specific biotransformation product of ethylenebisdithiocarbamates (EBDCs), has antithyroid activity. Thus, the aim of this study was to optimize for the first time the DPX extraction technique for quantification of ETU in urine through gas chromatography mass spectrometry (GC/MS), validate, and apply this methodology. The DPX parameters were evaluated with univariate analysis: sorption phases, sample pH, sample volumes, cleaning, and elution solvents. This methodology can be considered environmentally friendly; therefore, it complies with the principles of Green Chemistry, using low volumes of solvents, thus generating few chemical residues during the analyses. The DPX/GC–MS method developed showed linearity for concentrations ranging from 100 to 1000 µg L−1, with the coefficient of correlation (r) greater than 0.997 and the lack-of-fit test (p value) of 0.568 (p > 0.05), and the LOQ was 100 µg L−1. The intra-assay and inter-assay precision and accuracy showed acceptable values. Carryover was not observed according to acceptance criterion. It was found that there was a matrix effect (p < 0.001) (rotational type), which was solved using an external standard of ETU in water and in the urine biological matrix. Most were collected after 24 h of exposure to EBDCs, and the mean level of ETU was 4.07 µg g−1 creatinine. The DPX/GC–MS development method proved to be suitable for extraction and quantification of ETU in biological urine samples.
- 20 August 2025
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 197 (9) , 1-12
Disposable pipette extraction (DPX) of ethylenethiourea and analysis by gas chromatography coupled to mass spectrometry in urine samples of vineyard farmers
Disposable pipette extraction (DPX) is a modern miniaturized solid phase extraction technique that can be applied for analysis of different analytes in biological samples. Ethylenethiourea (ETU), a specific biotransformation product of ethylenebisdithiocarbamates (EBDCs), has antithyroid activity. Thus, the aim of this study was to optimize for the first time the DPX extraction technique for quantification of ETU in urine through gas chromatography mass spectrometry (GC/MS), validate, and apply this methodology. The DPX parameters were evaluated with univariate analysis: sorption phases, sample pH, sample volumes, cleaning, and elution solvents. This methodology can be considered environmentally friendly; therefore, it complies with the principles of Green Chemistry, using low volumes of solvents, thus generating few chemical residues during the analyses. The DPX/GC–MS method developed showed linearity for concentrations ranging from 100 to 1000 µg L−1, with the coefficient of correlation (r) greater than 0.997 and the lack-of-fit test (p value) of 0.568 (p > 0.05), and the LOQ was 100 µg L−1. The intra-assay and inter-assay precision and accuracy showed acceptable values. Carryover was not observed according to acceptance criterion. It was found that there was a matrix effect (p < 0.001) (rotational type), which was solved using an external standard of ETU in water and in the urine biological matrix. Most were collected after 24 h of exposure to EBDCs, and the mean level of ETU was 4.07 µg g−1 creatinine. The DPX/GC–MS development method proved to be suitable for extraction and quantification of ETU in biological urine samples.