An Adaptive Series-Dynamic-Resistor-Based Protection Scheme for Brushless Doubly- Fed Induction Generator Under Asymmetrical Fault Conditions
Open Access
- 10 January 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 11330-11339
Abstract
Low-voltage ride-through (LVRT) is one of the most important criteria for integrating wind energy into the power grid. Based on grid connection codes, wind generators must remain connected during fault conditions. However, this requires a careful protection scheme design for addressing the successful ride through of the brushless doubly fed induction generator (BDFIG) during severe voltage dips. This paper proposes a comprehensive solution for enhancing the BDFIG ride through during asymmetrical faults. Furthermore, since the proposed solution is dependent on the type and severity of voltage dips, an updated harmonic resilient scheme is developed to detect the dip level and type of faults. Performance of the proposed protection scheme is investigated for further improvement of the brushless DFIG LVRT capability based on series dynamic resistor (SDR) circuit design in order to limit post-fault oscillations. With the proposed solution, the BDFIG can satisfy ride through requirements for severe voltage dip scenarios. The proposed framework which includes a voltage detection method, appropriate SDR value determination procedure, and SDR control circuit was implemented and validated with a coupled circuit model in MATLAB/Simulink for a BDFIG prototype.Keywords
This publication has 36 references indexed in Scilit:
- An analytical study for low voltage ride through of the brushless doubly-fed induction generator during asymmetrical voltage dipsRenewable Energy, 2018
- Analyzing effectiveness of LVRT techniques for DFIG wind turbine system and implementation of hybrid combination with control schemesRenewable and Sustainable Energy Reviews, 2018
- Influence of Different Series Dynamic Resistors on Low-voltage Ride-through of Brushless Doubly Fed Induction GeneratorElectric Power Components and Systems, 2015
- Converter rating optimisation for a brushless doubly fed induction generatorIET Renewable Power Generation, 2015
- Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dipsInternational Journal of Electrical Power & Energy Systems, 2014
- Low voltage ride-through of DFIG and brushless DFIG: Similarities and differencesElectric Power Systems Research, 2014
- Wind Farms Fault Ride Through Using DFIG With New Protection SchemeIEEE Transactions on Sustainable Energy, 2012
- Wind Turbines Based on Doubly Fed Induction Generator Under Asymmetrical Voltage DipsIEEE Transactions on Energy Conversion, 2008
- Unified reference frame dq model of the brushless doubly fed machineIEE Proceedings - Electric Power Applications, 2006
- Voltage Sag Detection Technique for a Dynamic Voltage RestorerIEEE Transactions on Industry Applications, 2004