Robotic bronchoscopic needle‐based confocal laser endomicroscopy to diagnose peripheral lung nodules
- 19 December 2022
- journal article
- research article
- Published by Wiley in Respirology
- Vol. 28 (5) , 475-483
Abstract
Background and Objective: Robotic bronchoscopy has demonstrated high navigational success in small peripheral lung nodules but the diagnostic yield is discrepantly lower. Needle based confocal laser endomicroscopy (nCLE) enables real‐time microscopic imaging at the needle tip. We aim to assess feasibility, safety and needle repositioning based on real‐time nCLE‐guidance during robotic bronchoscopy in small peripheral lung nodules.Methods: Patients with suspected peripheral lung cancer underwent fluoroscopy and radial EBUS assisted robotic bronchoscopy. After radial EBUS nodule identification, nCLE‐imaging of the target area was performed. nCLE‐malignancy and airway/lung parenchyma criteria were used to identify the optimal sampling location. In case airway was visualized, repositioning of the biopsy needle was performed. After nCLE tool‐in‐nodule confirmation, needle passes and biopsies were performed at the same location.Measurements and Main Results: Twenty patients were included (final diagnosis n = 17 (lung) cancer) with a median lung nodule size of 14.5 mm (range 8–28 mm). No complications occurred. In 19/20 patients, good quality nCLE‐videos were obtained. In 9 patients (45%), real‐time nCLE‐imaging revealed inadequate positioning of the needle and repositioning was performed. After repositioning, nCLE‐imaging provided tool‐in‐nodule‐confirmation in 19/20 patients. Subsequent ROSE demonstrated representative material in 9/20 patients (45%) and overall diagnostic yield was 80% (16/20). Of the three patients with malignant nCLE‐imaging but inadequate pathology, two were diagnosed with malignancy during follow‐up.Conclusion: Robotic bronchoscopic nCLE‐imaging is feasible and safe. nCLE‐imaging in small, difficult‐to‐access lung nodules provided additional real‐time feedback on the correct needle positioning with the potential to optimize the sampling location and diagnostic yield.Keywords
Funding Information
- Johnson and Johnson
- Mauna Kea Technologies
- National Institutes of Health (P30CA006927)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (00770372)
This publication has 31 references indexed in Scilit:
- In- and ex-vivo molecular imaging of apoptosis to assess sensitivity of non-small cell lung cancer to EGFR inhibitors using probe-based confocal laser endomicroscopyPLOS ONE, 2017
- Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions. Results of the AQuIRE RegistryAmerican Journal of Respiratory and Critical Care Medicine, 2016
- Bronchus sign on thin-section computed tomography is a powerful predictive factor for successful transbronchial biopsy using endobronchial ultrasound with a guide sheath for small peripheral lung lesions: a retrospective observational studyBMC Medical Imaging, 2015
- Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional ExperienceAnnals of the American Thoracic Society, 2014
- Molecular confocal laser endomicroscopy: A novel technique forin vivocellular characterization of gastrointestinal lesionsWorld Journal of Gastroenterology, 2014
- Characteristics of Lung Cancers Detected by Computer Tomography Screening in the Randomized NELSON TrialAmerican Journal of Respiratory and Critical Care Medicine, 2013
- Diagnostic Yield of Electromagnetic Navigation Bronchoscopy Is Highly Dependent on the Presence of a Bronchus Sign on CT ImagingChest, 2010
- Factors Related to Diagnostic Sensitivity Using an Ultrathin Bronchoscope Under CT GuidanceChest, 2007
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971