CMChristopher Manley

Christopher Manley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher Manley has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thoracentesis for the Diagnosis and Management of Pleural Effusions: The Current State of a Centuries-Old Procedure

    by Michael J. Nicholson, Christopher Manley, Danish Ahmad

    Thoracentesis is a fundamental procedure in interventional pulmonology, providing both diagnostic and therapeutic value. This review article offers a comprehensive analysis of thoracentesis, delving into pleural anatomy, procedural techniques, indications, and recent advancements. The article details the evolution of thoracentesis, including the crucial role of ultrasound guidance and emerging approaches that enhance precision and minimize complications. It addresses the wide range of indications for thoracentesis in diverse clinical scenarios, from the diagnosis of pleural effusions to therapeutic drainage of pleural collections. Furthermore, this review explores the management of coagulopathy and anticoagulation pertaining to thoracentesis. It will also provide strategies for preventing and managing complications, ensuring that thoracentesis remains a well-tolerated procedure with minimal risks. This article concludes by examining future directions in thoracentesis, including potential innovations and trends that will shape the landscape of interventional pulmonary medicine. This review serves as an essential resource for pulmonologists, interventional radiologists, and healthcare professionals, offering a comprehensive update on thoracentesis.


  • Robotic bronchoscopic needle‐based confocal laser endomicroscopy to diagnose peripheral lung nodules

    by Christopher J. Manley, Tess Kramer, Rohit Kumar, Yulan Gong, Hormoz Ehya, Eric Ross, Peter I. Bonta, Jouke T. Annema

    Background and Objective: Robotic bronchoscopy has demonstrated high navigational success in small peripheral lung nodules but the diagnostic yield is discrepantly lower. Needle based confocal laser endomicroscopy (nCLE) enables real‐time microscopic imaging at the needle tip. We aim to assess feasibility, safety and needle repositioning based on real‐time nCLE‐guidance during robotic bronchoscopy in small peripheral lung nodules.Methods: Patients with suspected peripheral lung cancer underwent fluoroscopy and radial EBUS assisted robotic bronchoscopy. After radial EBUS nodule identification, nCLE‐imaging of the target area was performed. nCLE‐malignancy and airway/lung parenchyma criteria were used to identify the optimal sampling location. In case airway was visualized, repositioning of the biopsy needle was performed. After nCLE tool‐in‐nodule confirmation, needle passes and biopsies were performed at the same location.Measurements and Main Results: Twenty patients were included (final diagnosis n = 17 (lung) cancer) with a median lung nodule size of 14.5 mm (range 8–28 mm). No complications occurred. In 19/20 patients, good quality nCLE‐videos were obtained. In 9 patients (45%), real‐time nCLE‐imaging revealed inadequate positioning of the needle and repositioning was performed. After repositioning, nCLE‐imaging provided tool‐in‐nodule‐confirmation in 19/20 patients. Subsequent ROSE demonstrated representative material in 9/20 patients (45%) and overall diagnostic yield was 80% (16/20). Of the three patients with malignant nCLE‐imaging but inadequate pathology, two were diagnosed with malignancy during follow‐up.Conclusion: Robotic bronchoscopic nCLE‐imaging is feasible and safe. nCLE‐imaging in small, difficult‐to‐access lung nodules provided additional real‐time feedback on the correct needle positioning with the potential to optimize the sampling location and diagnostic yield.


  • Nodules, Navigation, Robotic Bronchoscopy, and Real-Time Imaging

    by Christopher J. Manley, Michael A. Pritchett

    The process of detection, diagnosis, and management of lung nodules is complex due to the heterogeneity of lung pathology and a relatively low malignancy rate. Technological advances in bronchoscopy have led to less-invasive diagnostic procedures and advances in imaging technology have helped to improve nodule localization and biopsy confirmation. Future research is required to determine which modality or combination of complimentary modalities is best suited for safe, accurate, and cost-effective management of lung nodules.


  • Robotic Navigational Bronchoscopy Combined with Needle-Based Confocal Laser Endomicroscopy: Case Report of a Novel Approach to Diagnose Small Lung Nodules

    by Christopher Manley, Tess Kramer, Rohit Kumar, Yulan Gong, Hormoz Ehya, Peter I. Bonta, Jouke Annema

    Lung cancer is the most commonly diagnosed cancer and the leading cause of cancer-related death. Advancements in navigational bronchoscopy have shown encouraging results but the diagnostic yield of small lung nodules by bronchoscopic techniques is still below that of transthoracic needle aspiration. The development of robotic bronchoscopy has demonstrated a significantly improved navigational success but the diagnostic yield is regularly limited by near-miss of the target nodule. Needle-based confocal laser endomicroscopy is a novel imaging technique that allows for the real-time visualization of individual cells and structures with microscopic resolution at the tip of the needle. We present the first reported case of confocal laser endomicroscopy guided robotic bronchoscopy for the real-time diagnosis of a small, partially cystic lung nodule.


  • Prospective randomized trial to compare the safety, diagnostic yield and utility of 22-gauge and 19-gauge endobronchial ultrasound transbronchial needle aspirates and processing technique by cytology and histopathology

    by Christopher J. Manley, Rohit Kumar, Yulan Gong, Min Huang, Shuanzeng (Sam) Wei, Rajeswari Nagarathinam, Alan Haber, Brian Egleston, Douglas Flieder, Hormoz Ehya


  • Late Breaking Abstract - Needle based confocal laser endomicroscopy for the diagnosis of peripheral lung nodules by robotic navigational bronchoscopy

    by Christopher Manley, Tess Kramer, Rohit Kumar, Lizzy Wijmans, Martijn De Bruin, Eric Ross, Yulan Gong, Hormoz Ehya, Peter Bonta, Jouke Annema

    Robotic navigational bronchoscopy (RNB) allows for high navigational success but diagnostic yield remains moderate due to near-miss of the target lesion. Needle based confocal laser endomicroscopy (nCLE) allows real-time lung cancer detection at the needle tip. We aim to assess feasibility, safety and needle repositioning based on nCLE-guidance during robotic bronchoscopy to reduce the current near-miss rate. Patients with suspected peripheral lung cancer based on (PET-)CT-scan underwent fluoroscopy and radial EBUS guided RNB. After lesion detection, an 18G needle containing the CLE probe, imaged the target area followed by TBNA and biopsies. In case of non-lesional CLE-imaging, readjustment of the robotic bronchoscope was performed. 17 patients were included (final diagnosis n=15 cancer, n=1 epithelioid granuloma, n =1 non-diagnostic) with a mean lesion size of 15 mm (range 8-30 mm). No complications occurred. In 14/15 (93%) of patients with cancer, nCLE-imaging detected a malignant pattern. In one patient alveolar parenchyma/ airway wall was visualized. One patient with a malignant nCLE pattern but negative robotic bronchoscopic lesion sampling was diagnosed with malignancy after surgery. In 6 patients (35%), nCLE guidance resulted in readjustment of the robotic bronchoscope with optimization of the sampling location, resulting in a diagnostic yield of 82%, (14/17, 13 patients with malignancy and 1 patient with epithelioid granuloma). In conclusion, robotic navigational bronchoscopy combined with nCLE-imaging is feasible, safe and can serve as a real-time guidance tool to fine-tune the sampling location to improve the diagnosis of peripheral lung cancer.


  • Open Access

    Robot-assisted bronchoscopy for pulmonary lesion diagnosis: results from the initial multicenter experience

    by Udit Chaddha, Stephen P. Kovacs, Christopher Manley, D. Kyle Hogarth, Gustavo Cumbo-Nacheli, Sivasubramanium V. Bhavani, Rohit Kumar, Manisha Shende, John P. Egan, Septimiu Murgu

    Background: The Robotic Endoscopic System (Auris Health, Inc., Redwood City, CA) has the potential to overcome several limitations of contemporary guided-bronchoscopic technologies for the diagnosis of lung lesions. Our objective is to report on the initial post-marketing feasibility, safety and diagnostic yield of this technology.Methods: We retrospectively reviewed data on consecutive cases in which robot-assisted bronchoscopy was used to sample lung lesions at four centers in the US (academic and community) from June 15th, 2018 to December 15th, 2018.Results: One hundred and sixty-seven lesions in 165 patients were included in the analysis, with an average follow-up of 185 ± 55 days. The average size of target lesions was 25.0 ± 15.0 mm. Seventy-one percent were located in the peripheral third of the lung. Pneumothorax and airway bleeding occurred in 3.6 and 2.4% cases, respectively. Navigation was successful in 88.6% of cases. Tissue samples were successfully obtained in 98.8%. The diagnostic yield estimates ranged from 69.1 to 77% assuming the cases of biopsy-proven inflammation without any follow-up information (N = 13) were non-diagnostic and diagnostic, respectively. The yield was 81.5, 71.7 and 26.9% for concentric, eccentric and absent r-EBUS views, respectively. Diagnostic yield was not affected by lesion size, density, lobar location or centrality.Conclusions: RAB implementation in community and academic centers is safe and feasible, with an initial diagnostic yield of 69.1–77% in patients with lung lesions that require diagnostic bronchoscopy. Comparative trials with the existing bronchoscopic technologies are needed to determine cost-effectiveness of this technology.