Serum Creatinine Determined by Jaffe, Enzymatic Method, and Isotope Dilution‐Liquid Chromatography‐Mass Spectrometry in Patients Under Hemodialysis
- 24 May 2012
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 26 (3) , 206-214
Abstract
Objectives: Serum creatinine is an important clinical marker for renal clearance. However, the Jaffe method had much interference and the accuracy had not been tested in patients under hemodialysis (HD) with standard isotope dilution‐liquid chromatography‐mass spectrometry (IDLCMS) method. The validity of enzymatic method is also unknown.Methods: The predialysis serum creatinine levels of 126 patients under regular HD for 3 months were checked by Jaffe, enzymatic, and IDLCMS methods. We compared the value of the Jaffe and enzymatic to that of IDLCMS in linear regression model. And we also tried to find the clinical parameters that influence the difference between Jaffe vs. IDLCMS and enzymatic vs. IDLCMS method.Results: We found significant underestimate serum creatinine in uremic patients by Jaffe and enzymatic methods. Serum glucose and globulin are positive biases, whereas albumin, potassium, and phosphorus are negative biases. Enzymatic method is less affected by serum glucose and serum protein. Albumin acts differently in uremic serum compared to the results of mixing them with normal serum.Conclusions: For uremic patients, in whom creatinine level is high and many of them suffered from diabetes mellitus, serum creatinine can be either under‐ or overestimated by Jaffe method. Enzymatic method is less affected and may be a better method. J. Clin. Lab. Anal. 26:206‐214, 2012.Keywords
This publication has 22 references indexed in Scilit:
- Metabolomic search for uremic toxins as indicators of the effect of an oral sorbent AST-120 by liquid chromatography/tandem mass spectrometryJournal of Chromatography B, 2010
- GC–MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assaysJournal of Chromatography B, 2010
- Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methodsJournal of Clinical Laboratory Analysis, 2010
- Glomerular filtration rate measurement and estimation in chronic kidney diseasePediatric Nephrology, 2007
- Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education ProgramClinical Chemistry, 2006
- A simplified method for HPLC determination of creatinine in mouse serumAmerican Journal of Physiology-Renal Physiology, 2004
- Glomerular filtration rate and creatinine production in adult icteric patientsClinica Chimica Acta, 1994
- The Effect of Neonatal Hyperbilirubinemia on the Measurement of Plasma CreatinineClinical Pediatrics, 1984
- Use of Serum Creatinine Concentrations to Determine Renal Function1Clinical Pharmacokinetics, 1979
- A Study of the Mechanism of the Jaffé ReactionClinical Chemistry and Laboratory Medicine (CCLM), 1974