A new screen-printed electrode for selective determination of bismuth in different authentic samples
Open Access
- 6 March 2023
- journal article
- research article
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (6) , 1481-1490
Abstract
A new potentiometric method based on the screen-printed ion-selective electrode (SPISE) was described for the determination of Bi(III) ion in different authentic samples. The novelty is based on, for the first time, the utilization of the cerium zirconium phosphotungstate (CZPT) in a screen-printed electrode (SPE) as a sensing material. In the literature, there is no screen-printed ion-selective electrode for the determination of Bi(III) ion. The influences of the paste composition, different conditioning parameters and foreign ions on the electrode performance were investigated. The reversibility and also response time of the electrode have been studied. The electrode showed a Nernstian response of 18.2 mV decade−1 in the concentration range of 3.3 × 10−7–1 × 10−1 mol. L−1. The electrode was found to be usable within the pH range of 3.5–8.0 and exhibited a fast response time, limit of detection (LOD) (1 × 10−7 mol. L−1), limit of quantification (LOQ) (3.33 × 10−7 mol. L−1), long lifetime and good stability. The matched potential method (MPM) was applied to determine the selectivity coefficient. The isothermal temperature coefficient (dEo/dt) of the electrode was calculated. The electrode was successfully applied for the determination of Bi(III) ion in different authentic samples. By comparing the current results with those obtained using inductively coupled plasma optical emission spectrometry, the nominated Bi(III) screen-printed ion-selective electrode has attained acceptable and efficient performance.Keywords
Funding Information
- Egyptian Atomic Energy Authority
This publication has 32 references indexed in Scilit:
- Headspace trapping of the hydrides on a Pd(II)-coated graphite adsorptive bar as a microextraction method for ETV–ICP-MS determination of Se, Te and Bi in seawater and human hair samplesTalanta, 2010
- An on-line preconcentration/separation system for the determination of bismuth in environmental samples by FAASTalanta, 2010
- Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry☆Talanta, 2009
- 1,3,4-Trisubstituted-2-azetidinone Derivatives as Novel Receptors for Bismuth(III) Ion-Selective Electrodes: Application in Pharmaceutical and Glass SamplesAnalytical Letters, 2009
- Potentiometric Carbon Paste Electrodes for the Determination of Bismuth in Some Pharmaceutical PreparationsBulletin of the Chemical Society of Japan, 2008
- Application of chitosan functionalized with 3,4-dihydroxy benzoic acid moiety for on-line preconcentration and determination of trace elements in water samplesMicrochimica Acta, 2007
- RETRACTED: Preconcentration and solid-phase extraction of beryllium, lead, nickel, and bismuth from various water samples using 2-propylpiperidine-1-carbodithioate with flame atomic absorption spectrometry (FAAS)Talanta, 2006
- On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometryAnalytica Chimica Acta, 2004
- A new cerium( IV ) vanadate‐based solid membrane electrode for bismuth( III )Electroanalysis, 1997
- Liquid-state membrane electrode sensitive to bismuth(III)Talanta, 1983