Refaat F. Aglan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Refaat F. Aglan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hosam M. Saleh
Radioisotope Department, Nuclear Research Center, Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt
5 shared publications - Hazem H. Mahmoud
Radioisotope Department, Nuclear Research Center, Egyptian Atomic Energy Authority (EAEA), Cairo 11787, Egypt
2 shared publications Mostafa M. Hamed
Analytical Chemistry and Control Department, Hot Laboratories and Waste Management Center, Egyptian Atomic Energy Authority, Cairo, Egypt
2 shared publications- Ahmed Mohamed Rashad
Central laboratory for Elemental and Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, p.O.Box, 13759, About Zabal, Egypt
1 shared publication - Amal I. Hassan
Department of Radioisotopes, Nuclear Research Centre, Egyptian Atomic Energy Authority, Egypt
1 shared publication - Mohamed M. Shehata
National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 6 March 2024
- Published by IntechOpen
Introductory Chapter: Foundations and Challenges in Hazardous Waste Management
Open access peer-reviewed chapter
- 6 March 2024
- Published by IntechOpen
Open AccessIntroductory Chapter: Foundations and Challenges in Hazardous Waste Management
Open access peer-reviewed chapter
- Open Access
- 3 November 2023
- Published by MDPI AG in Chemengineering
- Vol. 7 (6) , 106
Synthesis and Application of MnO-Fe2O3 Nanocomposites for the Removal of 137Cs and 60Co Radionuclides from Artificial Radioactive Aqueous Waste
For innovative application in wastewater treatment techniques, MnO-Fe2O3 nanocomposites were successfully synthesized using the sol–gel auto-combustion method at different temperatures for the adsorption of 137Cs and 60Co radionuclides from aqueous solution. The characterization of these nanocomposites was carried out through FT-IR, SEM-EDX, and X-ray diffraction. These nanocomposites were employed as adsorbent materials for the removal of 137Cs and 60Co radionuclides from simulated radioactive waste solutions. The study involved a series of experiments aiming to demonstrate the MnO-Fe2O3 nanoparticles’ exceptional adsorption potential concerning 137Cs and 60Co. Additionally, the investigation delved into how variations in temperature, dose amount, contact time, and pH value influence the adsorption dynamics. Due to their high specific surface area, the synthesized MnO-Fe2O3 nanoparticles had high adsorption capacity of more than 60% and 90% for 137Cs and 60Co, respectively. By investigation of kinetics and adsorption isotherms, pseudo-second-order reaction and the Langmuir model turned out to fit well for the adsorption of 137Cs and 60Co onto the MnO-Fe2O3 nanocomposites. Moreover, a thermodynamic analysis revealed that the adsorption process was spontaneous for both target metals and the adsorption of 60Co was endothermic, whereas the adsorption of 137Cs was exothermic.
- 3 November 2023
- Published by MDPI AG in Chemengineering
- Vol. 7 (6) , 106
Open AccessSynthesis and Application of MnO-Fe2O3 Nanocomposites for the Removal of 137Cs and 60Co Radionuclides from Artificial Radioactive Aqueous Waste
For innovative application in wastewater treatment techniques, MnO-Fe2O3 nanocomposites were successfully synthesized using the sol–gel auto-combustion method at different temperatures for the adsorption of 137Cs and 60Co radionuclides from aqueous solution. The characterization of these nanocomposites was carried out through FT-IR, SEM-EDX, and X-ray diffraction. These nanocomposites were employed as adsorbent materials for the removal of 137Cs and 60Co radionuclides from simulated radioactive waste solutions. The study involved a series of experiments aiming to demonstrate the MnO-Fe2O3 nanoparticles’ exceptional adsorption potential concerning 137Cs and 60Co. Additionally, the investigation delved into how variations in temperature, dose amount, contact time, and pH value influence the adsorption dynamics. Due to their high specific surface area, the synthesized MnO-Fe2O3 nanoparticles had high adsorption capacity of more than 60% and 90% for 137Cs and 60Co, respectively. By investigation of kinetics and adsorption isotherms, pseudo-second-order reaction and the Langmuir model turned out to fit well for the adsorption of 137Cs and 60Co onto the MnO-Fe2O3 nanocomposites. Moreover, a thermodynamic analysis revealed that the adsorption process was spontaneous for both target metals and the adsorption of 60Co was endothermic, whereas the adsorption of 137Cs was exothermic.
- Open Access
- 6 March 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (6) , 1481-1490
A new screen-printed electrode for selective determination of bismuth in different authentic samples
A new potentiometric method based on the screen-printed ion-selective electrode (SPISE) was described for the determination of Bi(III) ion in different authentic samples. The novelty is based on, for the first time, the utilization of the cerium zirconium phosphotungstate (CZPT) in a screen-printed electrode (SPE) as a sensing material. In the literature, there is no screen-printed ion-selective electrode for the determination of Bi(III) ion. The influences of the paste composition, different conditioning parameters and foreign ions on the electrode performance were investigated. The reversibility and also response time of the electrode have been studied. The electrode showed a Nernstian response of 18.2 mV decade−1 in the concentration range of 3.3 × 10−7–1 × 10−1 mol. L−1. The electrode was found to be usable within the pH range of 3.5–8.0 and exhibited a fast response time, limit of detection (LOD) (1 × 10−7 mol. L−1), limit of quantification (LOQ) (3.33 × 10−7 mol. L−1), long lifetime and good stability. The matched potential method (MPM) was applied to determine the selectivity coefficient. The isothermal temperature coefficient (dEo/dt) of the electrode was calculated. The electrode was successfully applied for the determination of Bi(III) ion in different authentic samples. By comparing the current results with those obtained using inductively coupled plasma optical emission spectrometry, the nominated Bi(III) screen-printed ion-selective electrode has attained acceptable and efficient performance.
- 6 March 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (6) , 1481-1490
Open AccessA new screen-printed electrode for selective determination of bismuth in different authentic samples
A new potentiometric method based on the screen-printed ion-selective electrode (SPISE) was described for the determination of Bi(III) ion in different authentic samples. The novelty is based on, for the first time, the utilization of the cerium zirconium phosphotungstate (CZPT) in a screen-printed electrode (SPE) as a sensing material. In the literature, there is no screen-printed ion-selective electrode for the determination of Bi(III) ion. The influences of the paste composition, different conditioning parameters and foreign ions on the electrode performance were investigated. The reversibility and also response time of the electrode have been studied. The electrode showed a Nernstian response of 18.2 mV decade−1 in the concentration range of 3.3 × 10−7–1 × 10−1 mol. L−1. The electrode was found to be usable within the pH range of 3.5–8.0 and exhibited a fast response time, limit of detection (LOD) (1 × 10−7 mol. L−1), limit of quantification (LOQ) (3.33 × 10−7 mol. L−1), long lifetime and good stability. The matched potential method (MPM) was applied to determine the selectivity coefficient. The isothermal temperature coefficient (dEo/dt) of the electrode was calculated. The electrode was successfully applied for the determination of Bi(III) ion in different authentic samples. By comparing the current results with those obtained using inductively coupled plasma optical emission spectrometry, the nominated Bi(III) screen-printed ion-selective electrode has attained acceptable and efficient performance.
- 3 January 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (7) , 1567-1579
Novel coated wire potentiometric sensor for selective determination of Mn(II) ions in various authentic samples
- 3 January 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (7) , 1567-1579
Novel coated wire potentiometric sensor for selective determination of Mn(II) ions in various authentic samples
- Open Access
- 5 February 2019
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 10 (1) , 7
Selective and sensitive determination of Cd(II) ions in various samples using a novel modified carbon paste electrode
- 5 February 2019
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 10 (1) , 7
Open AccessSelective and sensitive determination of Cd(II) ions in various samples using a novel modified carbon paste electrode