Detection of Bond Wire Lift-Off in Switching Tests Using Machine Learning
- 1 September 2025
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
This study utilised machine learning to analyse the switching waveforms of power semiconductor devices, with a particular focus on wire lift-off and the objective of detecting power cycling failures. Power semiconductor device losses generate heat during the operation of power electronics systems, resulting in power cycling failures. The gate voltage waveform ($V_{g s}$), the drain-source voltage waveform ($V_{d s}$), the source current waveform ($I_{s}$), and the combination of $V_{g s}$ and $I_{s}$ were employed as detection signals, and the accuracy of the analysis was compared using each waveform. Additionally, different types of M-shunts, with and without a coupling area, were utilised for current measurements to examine the effect of deliberate field coupling on the accuracy. The results demonstrate that the analysis employing the $V_{g s}$ waveform and the combined $V_{g s}$ and $I_{s}$ waveforms yield high accuracy for both the turn-off and turn-on conditions, with and without coupling. The use of shunts with coupling structures enables the chosen approach to distinguish between no cut and a single cut. By incorporating coupling structures, the theoretical approach gains practical applicability, as it allows for the detection of slight degradation effects in addition to discrete wire cuts.
Keywords
Funding Information
- Japan Society for the Promotion of Science (JSPS) (JPJSBP120243506)
This publication has 10 references indexed in Scilit:
- Estimating of IGBT Bond Wire Lift-Off Trend Using Convolutional Neural Network (CNN)IEEE Access, 2024
- Power-cycling degradation monitoring of an IGBT module with VCE(sat) measurement in continuous operation of a chopper circuitPower Electronic Devices and Components, 2024
- Bond wire lift-off detection by gate voltage waveform in IGBT turn-off process enhanced by digital gate controlPower Electronic Devices and Components, 2023
- Enhancement of turn-off gate voltage waveform change by digital gate control for bond wire lift-off detection in IGBT moduleMicroelectronics Reliability, 2023
- IGBT Junction Temperature Estimation via Gate Voltage Plateau SensingIEEE Transactions on Industry Applications, 2018
- In situ Condition Monitoring of IGBTs Based on the Miller Plateau DurationIEEE Transactions on Power Electronics, 2018
- Online Condition Monitoring for Both IGBT Module and DC-Link Capacitor of Power Converter Based on Short-Circuit Current SimultaneouslyIEEE Transactions on Industrial Electronics, 2017
- Condition Monitoring IGBT Module Bond Wires Fatigue Using Short-Circuit Current IdentificationIEEE Transactions on Power Electronics, 2016
- An Industry-Based Survey of Reliability in Power Electronic ConvertersIEEE Transactions on Industry Applications, 2011
- Elimination of the Skin Effect Error in Heavy-Current ShuntsIEEE Transactions on Power Apparatus and Systems, 1981