Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism
- 23 September 2012
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 251 (3) , 967-975
Abstract
To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. At 12 months postoperatively, the mean spherical equivalent was −0.15 ± 0.36 diopters (D) in the TICL group and −0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six (81.5 %) and 78 (94.0 %) eyes were within ±0.50 D for TICL and bioptics groups, respectively. The mean Snellen UDVA was not statistically different between both procedures (p = 0.909); 53 (65.4 %) and 54 (65.1 %) eyes achieved at least 20/25 or better in TICL and bioptics groups, respectively. No eye had lost more than two lines of CDVA, and 32.1 % of eyes (26/81) in the TICL group and 57.8 % of eyes (48/83) in the bioptics group had better postoperative UDVA than preoperative CDVA (p < 0.001). Safety was not statistically different between groups (p = 0.464) while efficacy was significantly higher in the bioptics group (p = 0.000). Two eyes with a TICL were treated to correct TICL decentration. Bioptics showed slightly better outcomes in some clinical measures such as uncorrected visual acuity, efficacy, and refractive predictability. TICL implantation shows reliable results similar to bioptics. A single procedure with TICL implantation might be preferred, eliminating the inherent risks of laser treatments and the risks of a second surgical procedure.Keywords
This publication has 29 references indexed in Scilit:
- Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-upJournal of Cataract & Refractive Surgery, 2011
- Comparison of the Toric Implantable Collamer Lens and Bioptics for Myopic AstigmatismJournal of Refractive Surgery, 2011
- Phakic intraocular lensesJournal of Cataract & Refractive Surgery, 2010
- One-Year Follow-up of Posterior Chamber Toric Phakic Intraocular Lens Implantation for Moderate to High Myopic AstigmatismOphthalmology, 2010
- Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatismJournal of Cataract & Refractive Surgery, 2010
- Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconusJournal of Cataract & Refractive Surgery, 2010
- Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatismJournal of Cataract & Refractive Surgery, 2010
- Comparison of Collamer toric contact lens implantation and wavefront-guided laser in situ keratomileusis for high myopic astigmatismJournal of Cataract & Refractive Surgery, 2008
- Wavefront-Guided LASIK for the Correction of Primary Myopia and AstigmatismOphthalmology, 2008
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004