Development of New Cs + Ion‐Selective Electrode with Alkyl‐Bridged Calix[4]arene Crown‐6 Compounds for the Determination of Cs + in Nuclear Waste Streams
- 13 November 2017
- journal article
- research article
- Published by Wiley in ChemistrySelect
- Vol. 2 (32) , 10347-10353
Abstract
A new liquid membrane based Ion Selective Electrodes (ISE) for Cs + employing three 1,3 cycloalkyloxy bridged calix[4]arene crown 6 ether compounds (L1: cyclooctyloxy, L2: cyclodecyloxy, L3: cyclotetradecyloxy) as ionophores were developed. The best response was observed when L3 was used as an ionophore. The cation exchange resin DOWEX‐50 W was used to maintain low activity of Cs + in inner filling solution (IFS) to improve the performance. With optimized IFS, Nernstian response (56.3 mV/decade of Cs + ) over the concentration range 10 −7 to 10 −2 M of Cs + was observed. Studies were also carried out to develop all solid contact Cs + ISE employing gold‐ polyaniline composites as a transducer. Superior response for Cs + was observed with IFS based ISE. The developed ISE showed detection limit of 3.7x10 −8 M Cs + with response time less than 20 seconds. Separate solution method was applied to determine selectivity for Cs + over alkali, alkaline earth and transition metal ions. The response of ISE for Cs + was fairly constant over the pH range 4–11. The concentration of Cs + was determined in two simulated high level active waste solutions and spiked tap water samples and results agreed well with atomic absorption spectroscopy (AAS) values and expected values, respectively.Keywords
This publication has 35 references indexed in Scilit:
- Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental SamplesAnalytical Chemistry, 2013
- Thermodynamic Study of the Complexation of p-Isopropylcalix[6]arene with Cs+ Cation in Dimethylsulfoxide-Acetonitrile Binary MediaMolecules, 2011
- Trace‐Level Determination of Cs+ Using Membrane‐Based Ion‐Selective ElectrodesElectroanalysis, 2006
- Crown bridged thiacalix[4]arenes as cesium-selective ionophores in solvent polymeric membrane electrodesAnalytica Chimica Acta, 2006
- Cesium selective electrodes based on novel double flexible spacers bridged biscalix[4]arenesAnalytica Chimica Acta, 2001
- SURVEYING THE EXTRACTION OF CESIUM NITRATE BY 1,3-ALTERNATECALIX[4]ARENE CROWN-6 ETHERS IN 1,2-DICHLOROETHANESolvent Extraction and Ion Exchange, 1999
- Cesium-selective chemically modified field effect transistors with calix[4]arene-crown-6 derivativesAnalytica Chimica Acta, 1995
- Anion effects on Donnan failure of aminated-poly(vinyl chloride)-based and neutral-carrier-based pH sensorsAnalytica Chimica Acta, 1993
- New artificial receptors from selectively functionalized calix[4]arenesSupramolecular Chemistry, 1993
- A cesium-selective electrode prepared from a crystalline synthetic zeolite of the mordenite typeAnalytica Chimica Acta, 1980