Pentapati S. Ramanjaneyulu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pentapati S. Ramanjaneyulu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
M. K. Saxena
Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
3 shared publicationsA. S. Kulkarni
Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
2 shared publications- Abha Naveen Kumar
Bhabha Atomic Research Centre
2 shared publications B. S. Tomar
Bhabha Atomic Research Centre
2 shared publicationsK. L. Ramakumar
Bhabha Atomic Research Centre
2 shared publications- A. K. Sanjukta
Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
1 shared publication
Latest Publications
- 19 April 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 324 (2) , 921-927
Studies on diffusion of hydrogen in PWR clad material
- 19 April 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 324 (2) , 921-927
Studies on diffusion of hydrogen in PWR clad material
- 13 November 2017
- Published by Wiley in ChemistrySelect
- Vol. 2 (32) , 10347-10353
Development of New Cs + Ion‐Selective Electrode with Alkyl‐Bridged Calix[4]arene Crown‐6 Compounds for the Determination of Cs + in Nuclear Waste Streams
A new liquid membrane based Ion Selective Electrodes (ISE) for Cs + employing three 1,3 cycloalkyloxy bridged calix[4]arene crown 6 ether compounds (L1: cyclooctyloxy, L2: cyclodecyloxy, L3: cyclotetradecyloxy) as ionophores were developed. The best response was observed when L3 was used as an ionophore. The cation exchange resin DOWEX‐50 W was used to maintain low activity of Cs + in inner filling solution (IFS) to improve the performance. With optimized IFS, Nernstian response (56.3 mV/decade of Cs + ) over the concentration range 10 −7 to 10 −2 M of Cs + was observed. Studies were also carried out to develop all solid contact Cs + ISE employing gold‐ polyaniline composites as a transducer. Superior response for Cs + was observed with IFS based ISE. The developed ISE showed detection limit of 3.7x10 −8 M Cs + with response time less than 20 seconds. Separate solution method was applied to determine selectivity for Cs + over alkali, alkaline earth and transition metal ions. The response of ISE for Cs + was fairly constant over the pH range 4–11. The concentration of Cs + was determined in two simulated high level active waste solutions and spiked tap water samples and results agreed well with atomic absorption spectroscopy (AAS) values and expected values, respectively.
- 13 November 2017
- Published by Wiley in ChemistrySelect
- Vol. 2 (32) , 10347-10353
Development of New Cs + Ion‐Selective Electrode with Alkyl‐Bridged Calix[4]arene Crown‐6 Compounds for the Determination of Cs + in Nuclear Waste Streams
A new liquid membrane based Ion Selective Electrodes (ISE) for Cs + employing three 1,3 cycloalkyloxy bridged calix[4]arene crown 6 ether compounds (L1: cyclooctyloxy, L2: cyclodecyloxy, L3: cyclotetradecyloxy) as ionophores were developed. The best response was observed when L3 was used as an ionophore. The cation exchange resin DOWEX‐50 W was used to maintain low activity of Cs + in inner filling solution (IFS) to improve the performance. With optimized IFS, Nernstian response (56.3 mV/decade of Cs + ) over the concentration range 10 −7 to 10 −2 M of Cs + was observed. Studies were also carried out to develop all solid contact Cs + ISE employing gold‐ polyaniline composites as a transducer. Superior response for Cs + was observed with IFS based ISE. The developed ISE showed detection limit of 3.7x10 −8 M Cs + with response time less than 20 seconds. Separate solution method was applied to determine selectivity for Cs + over alkali, alkaline earth and transition metal ions. The response of ISE for Cs + was fairly constant over the pH range 4–11. The concentration of Cs + was determined in two simulated high level active waste solutions and spiked tap water samples and results agreed well with atomic absorption spectroscopy (AAS) values and expected values, respectively.
- 12 June 2017
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 313 (3) , 581-586
Development of a new all solid contact Cs+ ion selective electrode
- 12 June 2017
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 313 (3) , 581-586
Development of a new all solid contact Cs+ ion selective electrode
- 9 September 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 302 (3) , 1231-1235
Development of methodology for the determination of boron in ThO2 employing spectrophotometry
- 9 September 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 302 (3) , 1231-1235
Development of methodology for the determination of boron in ThO2 employing spectrophotometry
- 12 November 2013
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 71 (11) , 4869-4888
Geochemical characterization of groundwater from an arid region in India
- 12 November 2013
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 71 (11) , 4869-4888
Geochemical characterization of groundwater from an arid region in India
- 15 October 2013
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 18 (6) , 525-531
Estimation of uncertainty in the determination of nitrogen and oxygen in U(Al, Si)3
- 15 October 2013
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 18 (6) , 525-531
Estimation of uncertainty in the determination of nitrogen and oxygen in U(Al, Si)3
- 15 February 2008
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 373 (1-3) , 75-81
Release of gases from uranium metal at high temperatures
- 15 February 2008
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 373 (1-3) , 75-81
Release of gases from uranium metal at high temperatures