Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction—First Clinical Results
- 4 June 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (11) , 2665-2673
Abstract
Goal: In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. Methods: Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. Results: The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. Conclusion: While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). Significance: The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.Keywords
Funding Information
- Swiss National Science Foundation (SNSF) (IZK0Z3_149048/1)
- Swiss KTI (13523.1 PFFLR-LS)
- KAKENHI (26108004, 25242051)
This publication has 29 references indexed in Scilit:
- Comparisons of Preoperative Three-Dimensional Planning and Surgical Reconstruction in Primary Cementless Total Hip ArthroplastyThe Journal of Arthroplasty, 2014
- An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation StudyAnnals of Biomedical Engineering, 2013
- Automated CT Segmentation of Diseased Hip Using Hierarchical and Conditional Statistical Shape Models2013
- New method for measuring acetabular component positioning with EOS imaging: feasibility study on dry boneInternational Orthopaedics, 2012
- A novel method of accurately calculating the radiological magnification of the hipThe Journal of Bone and Joint Surgery. British volume, 2009
- Accurate scaling of digital radiographs of the pelvisThe Journal of Bone and Joint Surgery. British volume, 2006
- Digital correction of magnification in pelvic x rays for preoperative planning of hip joint replacements: Theoretical development and clinical results of a new protocolMedical Physics, 2005
- Comparison of analog and digital preoperative planning in total hip and knee arthroplastiesActa Orthopaedica, 2005
- CT-based surgical planning software improves the accuracy of total hip replacement preoperative planningMedical Engineering & Physics, 2003
- A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templatingThe Journal of Bone and Joint Surgery. British volume, 2002