  • Radiographic reconstruction of lower-extremity bone fragments: a first trial

    by Steffen Schumann, Richard Bieck, Rainer Bader, Johannes Heverhagen, Lutz-P. Nolte, Guoyan Zheng

    Purpose The correct rotational alignment of the proximal and the distal bone fragments is an essential step in a long-bone deformity correction process. In order to plan the deformity correction, plain radiographs are conventionally used. But as three-dimensional information of the complex situation is not available, the correct amount of rotation can only be approximated. Thus, the objective of this study was to develop a system to assess the rotational relationship between the proximal and distal fragments of a long bone (tibia or femur) based on a set of two calibrated X-ray radiographs. Methods In order to robustly determine the rotational relationship of proximal and distal bone fragments, a statistical shape model-based 2D/3D reconstruction approach was employed. The resulting fragment models were used to determine the angle between its anatomical axes and the rotation around its particular axes. Two different studies were performed to evaluate the accuracy of the proposed system. Results The accuracy of the complete system was evaluated in terms of major bone axis and in-plane rotational difference. The angle between the anatomical fragment axes could be measured with an average error of 0.33\(^\circ \) ± 0.27\(^\circ \), while an average in-plane rotational error of 2.27\(^\circ \) ± 1.76\(^\circ \) and 2.67\(^\circ \) ± 1.80\(^\circ \) was found for the proximal and distal fragments, respectively. The overall mean surface reconstruction error was 0.81 ± 0.59 mm when the present technique was applied to the tibia and 1.12 ± 0.87 mm when it was applied to the femur. Conclusions A new approach for estimating the rotational parameters of long-bone fragments has been proposed. This approach is based on two conventional radiographs and 2D/3D reconstruction technology. It is generally applicable to the alignment of any long-bone fragments and could provide an important means for achieving accurate rotational alignment.


  • Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction—First Clinical Results

    by Steffen Schumann, Yoshinobu Sato, Yuki Nakanishi, Futoshi Yokota, Masaki Takao, Nobuhiko Sugano, Guoyan Zheng

    Goal: In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. Methods: Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. Results: The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. Conclusion: While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). Significance: The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.


  • X-ray image calibration and its application to clinical orthopedics

    by Steffen Schumann, Benedikt Thelen, Steven Ballestra, Lutz-P. Nolte, Philippe Büchler, Guoyan Zheng

    X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.


  • Statistical model-based segmentation of the proximal femur in digital antero-posterior (AP) pelvic radiographs

    by Weiguo Xie, Jochen Franke, Cheng Chen, Paul A. Grützner, Steffen Schumann, Lutz-P. Nolte, Guoyan Zheng

    Segmentation of the proximal femur in digital antero-posterior (AP) pelvic radiographs is required to create a three-dimensional model of the hip joint for use in planning and treatment. However, manually extracting the femoral contour is tedious and prone to subjective bias, while automatic segmentation must accommodate poor image quality, anatomical structure overlap, and femur deformity. A new method was developed for femur segmentation in AP pelvic radiographs.


  • An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study

    by Steffen Schumann, Li Liu, Moritz Tannast, Mathias Bergmann, Lutz-P. Nolte, Guoyan Zheng

    The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.


  • A CONSISTENT METHOD FOR MODELLING SUBJECT SPECIFIC MUSCULOSKELETAL SYSTEMS

    by Marcelo Elias de Oliveira, Michael Kistler, Rudolf de Almeida Prado Hellmuth, Nicolas Gerber, Steffen Schumann, Serena Bonaretti, Philippe Büchler

  • Determination of pelvic orientation from sparse ultrasound data for THA operated in the lateral position

    by Steffen Schumann, Lutz‐P. Nolte, Guoyan Zheng

    Background: B‐mode ultrasound imaging has the potential to replace conventional percutaneous digitization of bony landmarks in navigated total hip arthroplasties (THAs). For THAs operated in the lateral position, only one side of the pelvis is freely accessible. This paper presents a new ultrasound to statistical shape model (SSM) registration method for operating the pelvis in the lateral position, based on sparse ultrasound images, which does not interfere with the clinical routine in terms of redraping and repositioning the patient.Methods: It is proposed to use the mid‐sagittal plane of the pelvis to symmetrically reflect data derived from sparse B‐mode ultrasound images of the ipsilateral patient side to the contralateral side. A SSM of the pelvis is registered to the bilaterally available data without additional information on the pubic tubercle region.Results: The feasibility and robustness of the proposed method were evaluated by comprehensivein silicostudies and laboratory experiments with plastic and dry cadaveric pelvises, showing a mean error of 3.48 ± 1.10° for anteversion angle and 1.26 ± 1.62° for inclination angle.Conclusion: Experimental results demonstrate that the symmetry property of the pelvis could be used for registration in the lateral position without accessing the error‐prone pubic tubercle landmarks. Copyright © 2011 John Wiley & Sons, Ltd.