Common Methodology for Cardiac and Ocular Artifact Suppression from EEG Recordings by Combining Ensemble Empirical Mode Decomposition with Regression Approach
Authors:
Open Access
- 4 January 2017
- journal article
- research article
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 37 (2) , 201-208
Abstract
Electroencephalography (EEG) is a non-invasive way of recording brain activities, making it useful for diagnosing various neurological disorders. However, artifact signals associated with eye blinks or the heart spread across the scalp, contaminating EEG recordings and making EEG data analysis difficult. To solve this problem, we implement a common methodology to suppress both cardiac and ocular artifact signal, by correlating the measured contaminated EEG signals with the clean reference electro-oculography (EOG) and electrocardiography (EKG) data and subtracting the scaled EOG and EKG from the contaminated EEG recording. In the proposed methodology, the clean EOG and EKG signals are extracted by subjecting the raw reference time-series data to ensemble empirical mode decomposition to obtain the intrinsic mode functions. Then, an unsupervised technique is used to capture the artifact components. We compare the distortion introduced into the brain signal after artifact suppression using the proposed method with those obtained using conventional regression alone and with a wavelet-based approach. The results show that the proposed method outperforms the other techniques, with an additional advantage of being a common methodology for the suppression of two types of artifact.Keywords
This publication has 28 references indexed in Scilit:
- EOG Artifact Correction from EEG Recording Using Stationary Subspace Analysis and Empirical Mode DecompositionSensors, 2013
- Denoising EOG Signal using Stationary Wavelet TransformMeasurement Science Review, 2012
- REG-ICA: A hybrid methodology combining Blind Source Separation and regression techniques for the rejection of ocular artifactsBiomedical Signal Processing and Control, 2011
- Automatic removal of eye movement artifacts from the EEG using ICA and the dipole modelProgress in Natural Science: Materials International, 2009
- Ocular Reduction in EEG Signals Based on Adaptive Filtering, Regression and Blind Source SeparationAnnals of Biomedical Engineering, 2008
- Recovering EEG brain signals: Artifact suppression with wavelet enhanced independent component analysisJournal of Neuroscience Methods, 2006
- Removing electroencephalographic artifacts by blind source separationPsychophysiology, 2000
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisProceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 1998
- Independent component analysis, A new concept?Signal Processing, 1994
- Report of the committee on methods of clinical examination in electroencephalographyElectroencephalography and Clinical Neurophysiology, 1958