Measurement and optimization of the beam coupling impedance of a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber
Open Access
- 1 October 2023
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (10)
Abstract
Dipole magnet vacuum chambers are among the most critical and costly components of rapid-cycling accelerator facilities. Alternative approaches to traditional ceramic chambers have been explored for the implementation of fast-ramping dipole-magnet vacuum chambers, including thin-wall metallic beam pipe chambers strengthened with transverse ribs and ceramic rings inside thin-walled chambers. Here, we report a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber, which is designed for high-intensity heavy ion accelerator facility (HIAF) to reduce manufacturing difficulty and cost, shorten the production cycle, and improve the quality. Comprehensive studies were undertaken to characterize the impedance of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber. The beam-coupling impedance and eddy currents of the new thin-wall vacuum chamber were studied mostly numerically. Strategies for further reducing the beam-coupling impedance were explored. In addition, impedance bench measurements using the “half wavelength” resonant method were conducted to identify the longitudinal and transverse impedances of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber prototype experimentally. The simulated and measured results for the impedance were consistent. Furthermore, a campaign for resonance-check measurements on the 3D-printed titanium alloy ring loaded inside a thin-wall vacuum chamber prototype was launched. This novel thin-wall vacuum chamber structure is now entering the fabrication stage and will soon be ready for installation in the Booster Ring (BRing).Keywords
Funding Information
- National Natural Science Foundation of China (11825505, 12005274)
- National Key Research and Development Program of China (2019YFA0405400)
This publication has 18 references indexed in Scilit:
- The vacuum system of the China spallation neutron sourceVacuum, 2018
- Transverse impedances and collective instabilities in a heavy ion acceleratorPhysical Review Accelerators and Beams, 2018
- Design of extraction system in BRing at HIAFNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- HIAF: New opportunities for atomic physics with highly charged heavy ionsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2017
- A 3D printed superconducting aluminium microwave cavityApplied Physics Letters, 2016
- Metallic 3-D Printed Rectangular Waveguides for Millimeter-Wave ApplicationsIEEE Transactions on Components, Packaging and Manufacturing Technology, 2016
- Analytical evaluations of coupling impedances of resistive and magnetic bellowsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- High Intensity heavy ion Accelerator Facility (HIAF) in ChinaNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2013
- Analytical and numerical calculations of resistive wall impedances for thin beam pipe structures at low frequenciesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Vacuum system design for the 3 GeV-proton synchrotron of JAERI-KEK joint projectJournal of Vacuum Science & Technology A, 2002