Junxia Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junxia Wu has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Guangyu Zhu
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
11 shared publications Yuan Wei
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
7 shared publicationsZhixue Li
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
6 shared publications- Fafu Ni
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
5 shared publications Hongming Xie
Institute of Modern Physics, Chinese Academy of Sciences 1 , Lanzhou 730000, China
5 shared publications- Jian Cheng Yang
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
5 shared publications
Latest Publications
- 17 April 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (7) , 129
Beam-coupling impedance measurement and simulation of a movable collimator in BRing at HIAF
- 17 April 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (7) , 129
Beam-coupling impedance measurement and simulation of a movable collimator in BRing at HIAF
- 25 February 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (4) , 1-14
Development of heterogeneous multiprocessing digital beam position and phase monitor electronics at HIAF-iLinac
- 25 February 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (4) , 1-14
Development of heterogeneous multiprocessing digital beam position and phase monitor electronics at HIAF-iLinac
- 1 June 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (6)
Development of a non-intercepting weak beam current measurement electronics for Heavy Ion Accelerator Facility in Lanzhou
Non-destructive measurements of low-intensity charged particle beams are particularly challenging for beam diagnostics. At the Heavy Ion Accelerator Facility in Lanzhou (HIRFL), beams with weak currents below 1 µA are often provided for experiments. The detection of such low beam current is below the threshold of typical standard beam current transformers. Therefore, a low-intensity monitoring system is developed by using a sensitive capacitive pick-up (PU) and low-noise electronics. This device measures beam currents by digitally analyzing the amplitude of the PU signals using a homodyne detection scheme. During lab tests, the amplitude nonlinearity is <0.5% in the operational range of 1 nA–45 µA and the amplitude resolution is 0.94 nA. At present, four measurement systems for low beam currents are installed at HIRFL for the monitoring of standard operating conditions with low beam currents below 1 µA. After an absolute calibration with a Faraday cup, it can be used for accurate beam intensity measurement with a current resolution of about 1 nA.
- 1 June 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (6)
Development of a non-intercepting weak beam current measurement electronics for Heavy Ion Accelerator Facility in Lanzhou
Non-destructive measurements of low-intensity charged particle beams are particularly challenging for beam diagnostics. At the Heavy Ion Accelerator Facility in Lanzhou (HIRFL), beams with weak currents below 1 µA are often provided for experiments. The detection of such low beam current is below the threshold of typical standard beam current transformers. Therefore, a low-intensity monitoring system is developed by using a sensitive capacitive pick-up (PU) and low-noise electronics. This device measures beam currents by digitally analyzing the amplitude of the PU signals using a homodyne detection scheme. During lab tests, the amplitude nonlinearity is <0.5% in the operational range of 1 nA–45 µA and the amplitude resolution is 0.94 nA. At present, four measurement systems for low beam currents are installed at HIRFL for the monitoring of standard operating conditions with low beam currents below 1 µA. After an absolute calibration with a Faraday cup, it can be used for accurate beam intensity measurement with a current resolution of about 1 nA.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Design of a 0.15–2 GHz high-resolution vector-sum broadband phase shifter with controlled programmable attenuators for stochastic cooling system
In this paper, a new 0.15–2 GHz broadband phase shifter with 9-bit phase resolution is presented. This broadband digital adjustable phase shifter is implemented by utilizing the signal vector summation technology. The phase shifter consists of one 90° hybrid coupler, two digital attenuators, two 180° hybrid couplers, two microwave switches, and one combiner. By adjusting the attenuation value of the two digital attenuators, the device creates a minimum 0.7° stepped phase shift. In addition, by switching the two microwave switches, a 360° range of phase shift is achieved while almost keeping the amplitude of the phase shifter constant. The measurement results show that the proposed phase shifter achieves a phase resolution of 0.7° while exhibiting an average insertion loss of 9 ± 2 dB and phase unbalance within ±10°. The calculated RMS phase error of the broadband phase shifter is below 5° from 0.15 to 2 GHz.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessDesign of a 0.15–2 GHz high-resolution vector-sum broadband phase shifter with controlled programmable attenuators for stochastic cooling system
In this paper, a new 0.15–2 GHz broadband phase shifter with 9-bit phase resolution is presented. This broadband digital adjustable phase shifter is implemented by utilizing the signal vector summation technology. The phase shifter consists of one 90° hybrid coupler, two digital attenuators, two 180° hybrid couplers, two microwave switches, and one combiner. By adjusting the attenuation value of the two digital attenuators, the device creates a minimum 0.7° stepped phase shift. In addition, by switching the two microwave switches, a 360° range of phase shift is achieved while almost keeping the amplitude of the phase shifter constant. The measurement results show that the proposed phase shifter achieves a phase resolution of 0.7° while exhibiting an average insertion loss of 9 ± 2 dB and phase unbalance within ±10°. The calculated RMS phase error of the broadband phase shifter is below 5° from 0.15 to 2 GHz.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2515-2523
Development of a 128-Channel Readout System for a Multistrip Ionization Chamber in PREF
A new 128-channel readout system is designed for a multi-strip ionization chamber (MSIC) of the Proton Radiation Effects Facility (PREF) end station. This system consists of 128 ultra-low noise analog front-ends (AFE), 16 8-channel 60 Msps simultaneous sampling analog-to-digital converters (ADC), 8 Kintex-7 field-programmable gate arrays (FPGA), and a Zynq FPGA. It is capable of monitoring weak current signals of 25 pA-1.8 μA with an analog bandwidth of 1 kHz. The Kintex-7 FPGA is an intermediate buffer stage, designed to decode the ADC’s serial output data and to perform digital signal processing algorithms. Finally, the Zynq FPGA performs the data aggregation, beam profile fitting, and data interaction with the host computer. During offline tests, the effective number of bits (ENOB) is 12 bits at an AFE gain of 500 kΩ, and the nonlinearity of the full-scale is less than 0.12%. Finally, the system is deployed for the beam profile measurement with an MSIC at the Cooling Storage Ring of the Heavy-ion Research Facility in Lanzhou (HIRFL-CSR) and the PREF. This readout system not only performs an accurate beam profile measurement, but also can monitor the beam flatness, symmetry, and scanning uniformity. In a word, this system plays an important role in the fields of extremely weak beam profile measurements.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2515-2523
Development of a 128-Channel Readout System for a Multistrip Ionization Chamber in PREF
A new 128-channel readout system is designed for a multi-strip ionization chamber (MSIC) of the Proton Radiation Effects Facility (PREF) end station. This system consists of 128 ultra-low noise analog front-ends (AFE), 16 8-channel 60 Msps simultaneous sampling analog-to-digital converters (ADC), 8 Kintex-7 field-programmable gate arrays (FPGA), and a Zynq FPGA. It is capable of monitoring weak current signals of 25 pA-1.8 μA with an analog bandwidth of 1 kHz. The Kintex-7 FPGA is an intermediate buffer stage, designed to decode the ADC’s serial output data and to perform digital signal processing algorithms. Finally, the Zynq FPGA performs the data aggregation, beam profile fitting, and data interaction with the host computer. During offline tests, the effective number of bits (ENOB) is 12 bits at an AFE gain of 500 kΩ, and the nonlinearity of the full-scale is less than 0.12%. Finally, the system is deployed for the beam profile measurement with an MSIC at the Cooling Storage Ring of the Heavy-ion Research Facility in Lanzhou (HIRFL-CSR) and the PREF. This readout system not only performs an accurate beam profile measurement, but also can monitor the beam flatness, symmetry, and scanning uniformity. In a word, this system plays an important role in the fields of extremely weak beam profile measurements.
- Open Access
- 1 October 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (10)
Measurement and optimization of the beam coupling impedance of a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber
Dipole magnet vacuum chambers are among the most critical and costly components of rapid-cycling accelerator facilities. Alternative approaches to traditional ceramic chambers have been explored for the implementation of fast-ramping dipole-magnet vacuum chambers, including thin-wall metallic beam pipe chambers strengthened with transverse ribs and ceramic rings inside thin-walled chambers. Here, we report a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber, which is designed for high-intensity heavy ion accelerator facility (HIAF) to reduce manufacturing difficulty and cost, shorten the production cycle, and improve the quality. Comprehensive studies were undertaken to characterize the impedance of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber. The beam-coupling impedance and eddy currents of the new thin-wall vacuum chamber were studied mostly numerically. Strategies for further reducing the beam-coupling impedance were explored. In addition, impedance bench measurements using the “half wavelength” resonant method were conducted to identify the longitudinal and transverse impedances of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber prototype experimentally. The simulated and measured results for the impedance were consistent. Furthermore, a campaign for resonance-check measurements on the 3D-printed titanium alloy ring loaded inside a thin-wall vacuum chamber prototype was launched. This novel thin-wall vacuum chamber structure is now entering the fabrication stage and will soon be ready for installation in the Booster Ring (BRing).
- 1 October 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (10)
Open AccessMeasurement and optimization of the beam coupling impedance of a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber
Dipole magnet vacuum chambers are among the most critical and costly components of rapid-cycling accelerator facilities. Alternative approaches to traditional ceramic chambers have been explored for the implementation of fast-ramping dipole-magnet vacuum chambers, including thin-wall metallic beam pipe chambers strengthened with transverse ribs and ceramic rings inside thin-walled chambers. Here, we report a novel 3D-printed titanium alloy cage inside the thin-wall vacuum chamber, which is designed for high-intensity heavy ion accelerator facility (HIAF) to reduce manufacturing difficulty and cost, shorten the production cycle, and improve the quality. Comprehensive studies were undertaken to characterize the impedance of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber. The beam-coupling impedance and eddy currents of the new thin-wall vacuum chamber were studied mostly numerically. Strategies for further reducing the beam-coupling impedance were explored. In addition, impedance bench measurements using the “half wavelength” resonant method were conducted to identify the longitudinal and transverse impedances of the 3D-printed titanium alloy cage inside the thin-wall vacuum chamber prototype experimentally. The simulated and measured results for the impedance were consistent. Furthermore, a campaign for resonance-check measurements on the 3D-printed titanium alloy ring loaded inside a thin-wall vacuum chamber prototype was launched. This novel thin-wall vacuum chamber structure is now entering the fabrication stage and will soon be ready for installation in the Booster Ring (BRing).
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Stochastic cooling notch filter developments for the high-precision spectrometer ring in the high intensity heavy-ion accelerator facility project
Stochastic cooling of the high-precision spectrometer ring (SRing) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) project in China, which is used mainly for experiments with radioactive fragment beams, is applied to speed up the cooling process of a stored ion beam. In this article, a new coaxial-type notch filter with an amplitude equalizer in the long branch and an optical-type notch filter with phase-stabilized optical fiber are discussed and evaluated for the SRing stochastic cooling system. Both prototypes of coaxial and optical notch filters are fabricated and tested. The minimum notch depth of coaxial and optical notch filters reaches to 26 and 40 dB, respectively. The performance of both coaxial notch filter and optical fiber notch filter is presented in this work. These developments will be used not only for the longitudinal stochastic cooling system but also have potential for the beam feedback system.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Stochastic cooling notch filter developments for the high-precision spectrometer ring in the high intensity heavy-ion accelerator facility project
Stochastic cooling of the high-precision spectrometer ring (SRing) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) project in China, which is used mainly for experiments with radioactive fragment beams, is applied to speed up the cooling process of a stored ion beam. In this article, a new coaxial-type notch filter with an amplitude equalizer in the long branch and an optical-type notch filter with phase-stabilized optical fiber are discussed and evaluated for the SRing stochastic cooling system. Both prototypes of coaxial and optical notch filters are fabricated and tested. The minimum notch depth of coaxial and optical notch filters reaches to 26 and 40 dB, respectively. The performance of both coaxial notch filter and optical fiber notch filter is presented in this work. These developments will be used not only for the longitudinal stochastic cooling system but also have potential for the beam feedback system.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 235-244
Accurate Low Current Measurement Electronics With Self-Calibration Function for Ionization Chamber of Slow Extraction in HIAF
The new wide-range readout electronics with a self-calibration function are designed for ionization chambers in the slow extraction of High-Intensity Heavy Ion Accelerator Facility, Booster Ring. These electronics consist of a programmable transimpedance amplifier, a self-calibration circuit, an 18-bit analog-to-digital converter, and a ZYNQ-7015 field-programmable gate array. It is capable of monitoring weak current signals of 40 pA-4 mA with a sampling rate of 5 MHz. The ZYNQ-7015 FPGA manages the operation mode of the analog front-end and the gain of the trans-impedance amplifier. It also performs digital signal processing algorithms and data communication with the host computer. The self-calibration circuit uses a combination of a Schmitt trigger and voltage-to-current converters to generate 2 square wave current signals with different peaks (2 μA, 2 mA). During offline tests, the effective number of bits is 12.98 bits, and the nonlinearity is less than 0.075% for a full scale. Finally, the readout electronics are deployed for ionization chambers’ slow extraction measurements at the extraction line of the cooling storage ring of the Heavy Ion Research Facility in Lanzhou. With the help of a commercial DC-transformer in the HIRFL-CSR, these electronics not only execute an accurate current measurement, but also can monitor the extraction efficiency reliably. In a word, these electronics play an important role in the fields of extremely weak and high dynamic current signal measurements.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 235-244
Accurate Low Current Measurement Electronics With Self-Calibration Function for Ionization Chamber of Slow Extraction in HIAF
The new wide-range readout electronics with a self-calibration function are designed for ionization chambers in the slow extraction of High-Intensity Heavy Ion Accelerator Facility, Booster Ring. These electronics consist of a programmable transimpedance amplifier, a self-calibration circuit, an 18-bit analog-to-digital converter, and a ZYNQ-7015 field-programmable gate array. It is capable of monitoring weak current signals of 40 pA-4 mA with a sampling rate of 5 MHz. The ZYNQ-7015 FPGA manages the operation mode of the analog front-end and the gain of the trans-impedance amplifier. It also performs digital signal processing algorithms and data communication with the host computer. The self-calibration circuit uses a combination of a Schmitt trigger and voltage-to-current converters to generate 2 square wave current signals with different peaks (2 μA, 2 mA). During offline tests, the effective number of bits is 12.98 bits, and the nonlinearity is less than 0.075% for a full scale. Finally, the readout electronics are deployed for ionization chambers’ slow extraction measurements at the extraction line of the cooling storage ring of the Heavy Ion Research Facility in Lanzhou. With the help of a commercial DC-transformer in the HIRFL-CSR, these electronics not only execute an accurate current measurement, but also can monitor the extraction efficiency reliably. In a word, these electronics play an important role in the fields of extremely weak and high dynamic current signal measurements.
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (6) , 063301
A new digital beam position and phase measurement implementation based on a field programmable gate array for the high intensity heavy-ion accelerator iLinac
A new digital beam position and phase measurement (BPM) system was designed for the ion-Linac accelerator at the high intensity heavy ion accelerator facility. The fundamental and second harmonic signals are retrieved from the BPM electrodes to simultaneously calculate their respective beam positions and phases. All data acquisition and digital signal processing algorithm routines are performed in a field programmable gate array (FPGA). The position and phase information are obtained by using the in-phase and quadrature demodulation method. A practical and straightforward method is used to generate the second harmonic reference signal for processing the second harmonic beam signal. The reconfigurable filters are integrated into the FPGA to allow the measurement of short beam pulse length. The laboratory test results show that the achieved phase resolution is better than 0.2° and 0.03° when the input signal is −60 and −45 dBm, respectively. A position resolution better than 30 μm was achieved for an input power level of approximately −60 dBm, and it can reach 7 μm with the input power higher than −45 dBm. The entire execution time of the algorithm is accomplished within 3.4 µs, which provides a sufficient reaction time for the fast beam interlock signal to the machine protection system. The performance of this newly designed prototype BPM electronics was evaluated with the online proton beam.
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (6) , 063301
A new digital beam position and phase measurement implementation based on a field programmable gate array for the high intensity heavy-ion accelerator iLinac
A new digital beam position and phase measurement (BPM) system was designed for the ion-Linac accelerator at the high intensity heavy ion accelerator facility. The fundamental and second harmonic signals are retrieved from the BPM electrodes to simultaneously calculate their respective beam positions and phases. All data acquisition and digital signal processing algorithm routines are performed in a field programmable gate array (FPGA). The position and phase information are obtained by using the in-phase and quadrature demodulation method. A practical and straightforward method is used to generate the second harmonic reference signal for processing the second harmonic beam signal. The reconfigurable filters are integrated into the FPGA to allow the measurement of short beam pulse length. The laboratory test results show that the achieved phase resolution is better than 0.2° and 0.03° when the input signal is −60 and −45 dBm, respectively. A position resolution better than 30 μm was achieved for an input power level of approximately −60 dBm, and it can reach 7 μm with the input power higher than −45 dBm. The entire execution time of the algorithm is accomplished within 3.4 µs, which provides a sufficient reaction time for the fast beam interlock signal to the machine protection system. The performance of this newly designed prototype BPM electronics was evaluated with the online proton beam.
- 1 April 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (4) , 043306
Development of a diagonal-cut type beam position monitor for the booster ring in the High Intensity Heavy-Ion Accelerator Facility project
A diagonal-cut type beam position monitor (BPM) has been developed for the High Intensity Heavy-Ion Accelerator Facility (HIAF) project at the Institute of Modern Physics. Compared with other types of BPMs, the diagonal-cut type BPM has almost perfect position linearity, i.e., no non-linear correction required, which is advantageous for beams that are transversally large and have a complex charge distribution. The key parameters for the diagonal-cut type BPM have been simulated and optimized in detail and systematically herein. It was found that the crosstalk is improved by ∼10 dB at 160 MHz by insertion of a separate ring between two horizontal or vertical electrodes of the BPM made of stainless steel with vacuum as a dielectric. Furthermore, the longitudinal and transverse numerical simulation to evaluate the beam impedance on the diagonal-cut type BPM has been performed. The results for the crosstalk, position sensitivity, and electrode capacitance to ground obtained from simulations and laboratory measurements agree well. The vacuum of the BPM prototype after baking out at 250 °C for 72 h is better than 1.0 × 10−11 mbar. The simulated and on-line measured BPM output signal magnitude results are consistent with each other. This diagonal-cut type BPM structure will be considered for application to the HIAF project as a priority.
- 1 April 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (4) , 043306
Development of a diagonal-cut type beam position monitor for the booster ring in the High Intensity Heavy-Ion Accelerator Facility project
A diagonal-cut type beam position monitor (BPM) has been developed for the High Intensity Heavy-Ion Accelerator Facility (HIAF) project at the Institute of Modern Physics. Compared with other types of BPMs, the diagonal-cut type BPM has almost perfect position linearity, i.e., no non-linear correction required, which is advantageous for beams that are transversally large and have a complex charge distribution. The key parameters for the diagonal-cut type BPM have been simulated and optimized in detail and systematically herein. It was found that the crosstalk is improved by ∼10 dB at 160 MHz by insertion of a separate ring between two horizontal or vertical electrodes of the BPM made of stainless steel with vacuum as a dielectric. Furthermore, the longitudinal and transverse numerical simulation to evaluate the beam impedance on the diagonal-cut type BPM has been performed. The results for the crosstalk, position sensitivity, and electrode capacitance to ground obtained from simulations and laboratory measurements agree well. The vacuum of the BPM prototype after baking out at 250 °C for 72 h is better than 1.0 × 10−11 mbar. The simulated and on-line measured BPM output signal magnitude results are consistent with each other. This diagonal-cut type BPM structure will be considered for application to the HIAF project as a priority.