Combining Engineering Precision with Clinical Relevance: A Novel Dual Framework for Assessing Pedicle Screw Accuracy in Spine Surgery
Open Access
- 18 March 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2328
Abstract
Background/Objectives: Accurate pedicle screw placement is critical in spine surgery, as malposition can cause neurological, vascular, or visceral injuries and compromise construct stability. The primary objective of this study was to develop and experimentally validate a dual quantitative framework for assessing pedicle screw placement accuracy, combining (1) coaxiality, a standardized geometric metric of trajectory alignment, and (2) pedicle wall distance (dpw), a novel parameter defined as the minimal distance between the screw axis and the pedicle cortex providing surgeons with direct, millimetric, clinically actionable feedback. A secondary objective was to compare these parameters: dpw, coaxiality, entry point errors and orientation angle errors between senior surgeons and residents to evaluate the influence of surgical experience. We hypothesized that this framework would provide reproducible quantitative measurements, demonstrate strong agreement with established CBCT-based grading systems, and allow meaningful subgroup comparisons by experience level. Methods: Eight operators (four senior surgeons, four residents) performed 240 pedicle screw insertions on synthetic polyurethane lumbar spine models using freehand, CBCT-assisted, and navigation-assisted techniques. Predefined 3D trajectories were compared with actual screw positions digitized with sub-millimetric precision. Errors, coaxiality, and dpw were computed, and dpw was validated against CBCT-based Gertzbein and Heary classifications. Agreement and diagnostic performance metrics (Kappa, sensitivity, specificity) were calculated. Results: Of 236 analyzable screws, coaxiality correlated with entry point errors (ρ = 0.41), target point errors (ρ = 0.85), and orientation angle errors (ρ = 0.48), confirming its robustness as an engineering metric. dpw provided immediate, interpretable feedback and demonstrated near-perfect agreement with CBCT grading (Kappa = 0.86; sensitivity = 0.96; specificity = 0.97), detecting breaches missed by qualitative classifications. Subgroup analyses indicated small but significant differences between senior and junior surgeons for target point errors (p = 0.006), orientation angle errors (p = 0.025), and coaxiality (p = 0.023), whereas entry point errors (p = 0.201) and dpw (p = 0.163) did not differ significantly. Conclusions: This dual-metric framework bridges engineering rigor and intraoperative applicability. Coaxiality supports reproducible research assessment, while dpw enables actionable surgical feedback. The framework allows objective comparison across operators of different experience levels. Together, these metrics offer a standardized, clinically relevant, and quantitative method for evaluating pedicle screw placement, with potential to enhance surgical safety, education, and patient outcomes.Keywords
Funding Information
- Siemens Healthcare (2015 BB2B-1-105)
This publication has 38 references indexed in Scilit:
- Accuracy of a patient-specific template for pedicle screw placement compared with a conventional method: a meta-analysisArchives of orthopaedic and trauma surgery, 2017
- Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric studyEuropean Spine Journal, 2015
- A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracyEuropean Spine Journal, 2015
- Robot-assisted spine surgery: feasibility study through a prospective case-matched analysisEuropean Spine Journal, 2015
- Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy2012
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studiesEuropean Spine Journal, 2010
- Complications associated with thoracic pedicle screws in spinal deformityEuropean Spine Journal, 2010
- Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operationsEuropean Spine Journal, 2002
- Pedicle screw fixation in spinal disorders: A European viewEuropean Spine Journal, 1997