In Vivo Evaluation of Physiologic Control Algorithms for Left Ventricular Assist Devices Based on Left Ventricular Volume or Pressure
- 1 September 2017
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (5) , 568-577
Abstract
Turbodynamic left ventricular assist devices (LVADs) provide a continuous flow depending on the speed at which the pump is set, and do not adapt to the changing requirements of the patient. The limited adaptation of the pump flow (PF) to the amount of venous return can lead to ventricular suction or overload. Physiologic control may compensate such situations by an automatic adaptation of the PF to the volume status of the left ventricle. We evaluated two physiologic control algorithms in an acute study with eight healthy pigs. Both controllers imitate the Frank–Starling law of the heart and are based on a measurement of the left ventricular volume (LVV) or pressure (LVP), respectively. After implantation of a modified Deltastream DP2 blood pump as an LVAD, we tested the responses of the physiologic controllers to hemodynamic changes and compared them with the response of the constant speed (CS) mode. Both physiologic controllers adapted the pump speed (PS) such that the flow was more sensitive to preload and less sensitive to afterload, as compared with the CS mode. As a result, the risk for suction was strongly reduced. Five suction events were observed in the CS mode, one with the volume-based controller and none with the pressure-based controller. The results suggest that both physiologic controllers have the potential to reduce the number of adverse events when used in the clinical setting.Keywords
This publication has 33 references indexed in Scilit:
- Seventh INTERMACS annual report: 15,000 patients and countingThe Journal of Heart and Lung Transplantation, 2015
- A monitoring and physiological control system for determining aortic valve closing with a ventricular assist deviceEuropean Journal of Cardio-Thoracic Surgery, 2014
- Developments in control systems for rotary left ventricular assist devices for heart failure patients: a reviewPhysiological Measurement, 2012
- Safety‐Enhanced Optimal Control of Turbodynamic Blood PumpsArtificial Organs, 2011
- Suction Due to Left Ventricular Assist: Implications for Device Control and ManagementArtificial Organs, 2007
- The development of control techniques for ventricular-assist devices and a hierarchical control structure to regulate the operation of a turbo-hydrodynamic assist device - Hierarchical control of heart-assist devicesIEEE Robotics & Automation Magazine, 2003
- Interaction of the Cardiovascular System with an Implanted Rotary Assist Device: Simulation Study with a Refined Computer Model>Artificial Organs, 2002
- Control Strategy for Rotary Blood PumpsArtificial Organs, 2001
- Sensorless Controlling Method for a Continuous Flow Left Ventricular Assist DeviceArtificial Organs, 2000
- Controller for an Axial Flow Blood PumpArtificial Organs, 1996