Polarity Behavior of Decrement‐Evoked Potentials in Functional Substrate Mapping of Ventricular Tachycardia
- 17 March 2026
- journal article
- case report
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (4) , 889-892
Abstract
Introduction: Decrement‐evoked potentials (DEEPs) are used to identify the functional substrate during ventricular tachycardia (VT) ablation, but distinguishing arrhythmogenic from bystander DEEPs remains challenging. Methods and Results: During substrate‐based VT ablation, DEEPs were analyzed using a predefined early evaluation window and dominant initial deflection during S1 pacing and S2 extrastimulus. DEEPs exhibiting polarity change between S1 and S2 were observed at the critical ablation site, whereas DEEPs without polarity change were found at non‐critical sites. Ablation at the polarity‐changing DEEP site was effective. Conclusion: DEEP polarity behavior may help differentiate critical VT substrate from bystander regions.Keywords
This publication has 3 references indexed in Scilit:
- State of the Art: Mapping Strategies to Guide Ablation in Ischemic Heart DiseaseJACC: Clinical Electrophysiology, 2024
- Quantifying the determinants of decremental response in critical ventricular tachycardia substrateComputers in Biology and Medicine, 2018
- Multicenter Study of Ischemic Ventricular Tachycardia Ablation With Decrement-Evoked Potential (DEEP) Mapping With Extra StimulusJACC: Clinical Electrophysiology, 2018