MWMasaya Watanabe

Masaya Watanabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masaya Watanabe has a total of 130 co-authors. Here are the top co-authors by number of shared publications:

  • Toshihisa Anzai

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan

    18 shared publications
  • Rui Kamada

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan

    12 shared publications
  • Takahide Kadosaka

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan

    12 shared publications
  • Hikaru Hagiwara

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan

    11 shared publications
  • Motoki Nakao

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan

    11 shared publications
  • Taro Koya

    Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine Hokkaido University Sapporo Japan

    11 shared publications

Latest Publications

  • Open Access

    Cardiac Resynchronization Therapy With Defibrillator Using the JROAD-DPC Database: Cost-Effectiveness Analysis

    by Kazuki Ohashi, Masaya Watanabe, Yasuhiro Morii, Hisashi Yokoshiki, Kengo Kusano, Katsuhiko Imai, Masahiko Takagi, Teiichi Yamane, Hiroshi Tada, Katsuhiko Ogasawara

    Background: Cardiac resynchronization therapy with defibrillator (CRT-D) improves survival, reduces hospitalization, and enhances quality of life in patients with heart failure and reduced ejection fraction (HFrEF). As heart failure prevalence increases in aging societies such as Japan, the associated clinical and economic burden continues to rise. Previous cost-effectiveness analyses conducted in multiple countries indicate that CRT-D may be cost-effective in selected patients with HFrEF. However, its cost-effectiveness within the Japanese health care system remains uncertain. Objective: This study aimed to evaluate the cost-effectiveness of CRT-D in patients with HFrEF within the Japanese health care setting. Methods: A partitioned survival model was developed with 3 health states: after treatment (follow-up), hospitalization, and death. Survival for CRT-D was estimated by reconstructing individual patient-level data from the Kaplan-Meier curve of the RAFT (Resynchronization-Defibrillation for Ambulatory Heart Failure Trial) study using the method proposed by Guyot et al followed by fitting multiple parametric models; the gamma distribution was selected for the base case analysis. Survival for optimal medical therapy (OMT), the comparator, was estimated by applying a hazard ratio from a published meta-analysis. Hospitalization rates and device longevity were derived from prior studies. Cost estimates were obtained from the JROAD-DPC (Japanese Registry Of All cardiac and vascular Disease-Diagnostic Procedure Combination) database and the Japanese medical fee schedule. Utility values were assigned according to New York Heart Association class assuming treatment-specific distributions. The analysis was conducted from the public health care payer perspective using a monthly cycle over a 20-year time horizon. Deterministic and probabilistic sensitivity analyses were performed. Additionally, scenario analyses were conducted by varying the duration of treatment effect. Results: In the base case analysis, per capita costs were ¥12,258,410 (¥1=US $0.006 as of July 7, 2026) for CRT-D and ¥640,056.90 for OMT, resulting in an incremental cost of ¥11,618,353. CRT-D generated 7.07 quality-adjusted life years (QALYs) compared with 4.75 QALYs for OMT, yielding an incremental gain of 2.32 QALYs. The incremental cost-effectiveness ratio (ICER) was ¥5,009,880 per QALY. Scenario analyses showed that, when treatment effect waned after 7.5 years, the ICER increased to ¥5,423,235 per QALY. When the time horizon was shortened to 10 years or extended to 30 years, the ICERs were ¥8,523,072 and ¥4,386,803 per QALY, respectively. Deterministic sensitivity analysis identified CRT-D efficacy (hazard ratio), discount rate, and initial treatment cost as primary ICER drivers. Probabilistic sensitivity analysis produced a median ICER of ¥5,022,618 (IQR ¥4,448,306–¥5,760,425) per QALY, with a 95% credible interval of ¥3,804,418 to ¥7,178,795. At a willingness-to-pay value of ¥5,000,000 per QALY, CRT-D had a 49.2% probability of being cost-effective. Conclusions: CRT-D demonstrated acceptable cost-effectiveness in patients with HFrEF in Japan. Treatment efficacy and initial cost were the primary determinants of economic value, emphasizing the importance of appropriate patient selection and strategies to reduce device costs.

  • Different Effects of Defibrillator Shocks on the Myocardial Damage Between Subcutaneous and Transvenous Implantable Cardioverter‐Defibrillators

    by Takahide Kadosaka, Masaya Watanabe, Motoki Nakao, Taro Koya, Hikaru Hagiwara, Hiroyuki Gibo, Taro Temma, Kazuya Mizukami, Hisashi Yokoshiki, Toshihisa Anzai

    Background: Although the implantable cardioverter defibrillators (ICD) are the only established treatment to prevent sudden cardiac death, previous studies reported that those who receive shock therapies, whether appropriate or inappropriate, have a higher risk of death. However, the difference in the influence of shock therapies between via Transvenous‐ICD (TV‐ICD) and Subcutaneous‐ICD (S‐ICD) has not been adequately examined. We aimed to investigate the influence of shocks on myocardium in patients with TV‐ICD and S‐ICD. Methods: We enrolled consecutive patients who received a defibrillator or transvenous pacemaker (TV‐PM) implantation between November 2020 and March 2024. A total of 74 patients were included in this study and divided into three groups: patients with TV‐ICD with defibrillation testing (DFT) (TV‐DFT, 27 patients), those with transvenous devices implanted without DFT (TV‐no DFT, 25 patients) and those with S‐ICD (22 patients). Results: Delta log troponin‐I (the difference of serum troponin‐I levels between baseline and after implantation) was significantly increased in TV‐DFT group. In patients with TV‐ICD (46 patients), Delta log troponin‐I was significantly correlated with total shock joules. In the multivariable linear regression analysis, a value of total shock joules was independently associated with delta troponin‐I. Conclusion: Elevation of serum troponin‐I was associated with the TV‐ICD shocks and correlated with the total shock energy, but not with S‐ICD shocks. Our results suggest that TV‐ICD shocks are associated with greater myocardial injury compared to S‐ICD shocks, and that total shock energy is an important determinant of the extent of myocardial damage.

  • Open Access

    Current Status of Implantable Cardioverter‐Defibrillators ( ICDs )/Cardiac Resynchronization Therapy With Defibrillators ( CRT ‐Ds) for Primary Prevention of Sudden Cardiac Death

    by Hisashi Yokoshiki, Masaya Watanabe, Takeshi Mitsuhashi, Akihiko Shimizu

    Among recipients of implantable cardioverter‐defibrillators (ICDs) or cardiac resynchronization therapy with defibrillators (CRT‐Ds), non‐ischemic etiology is predominant, accounting for more than 60% of cases in Japan, which is higher than that in the United States and other European countries. Despite recent concerns about primary prevention ICD/CRT‐D implantation for non‐ischemic patients with systolic heart failure in advanced guideline‐directed medical therapy (GDMT), ICD/CRT‐D therapy is likely effective in reducing the slope of the relationship between all‐cause death and sudden cardiac death. Two cohort studies in Japan have shown that the cumulative incidence of appropriate ICD/CRT‐D therapy is higher among non‐ischemic patients than ischemic patients receiving primary prevention ICD/CRT‐D implantation. Additionally, recent published cohort studies in the United States, Europe, and Japan reported a significant decrease in the risk of all‐cause death in primary prevention ICD/CRT‐D recipients compared to those without ICD/CRT‐D therapy. Notably, ICD/CRT‐D utilization in Japan is the lowest among the Group of Seven (G7) countries. Governmental acknowledgment of the value of primary prevention ICD/CRT‐D therapy, as well as educational activities for non‐cardiac electrophysiologists, are required to prevent a potential labor shortage and an excess of healthcare costs following out‐of‐hospital cardiac arrest (OHCA).


  • Polarity Behavior of Decrement‐Evoked Potentials in Functional Substrate Mapping of Ventricular Tachycardia

    by Taro Temma, Masaya Watanabe, Hisashi Yokoshiki, Ryo Sasaki, Ryudai Hirako, Toshihisa Anzai

    Introduction: Decrement‐evoked potentials (DEEPs) are used to identify the functional substrate during ventricular tachycardia (VT) ablation, but distinguishing arrhythmogenic from bystander DEEPs remains challenging. Methods and Results: During substrate‐based VT ablation, DEEPs were analyzed using a predefined early evaluation window and dominant initial deflection during S1 pacing and S2 extrastimulus. DEEPs exhibiting polarity change between S1 and S2 were observed at the critical ablation site, whereas DEEPs without polarity change were found at non‐critical sites. Ablation at the polarity‐changing DEEP site was effective. Conclusion: DEEP polarity behavior may help differentiate critical VT substrate from bystander regions.

  • Open Access

    Double-balloon venous ethanol ablation for postinfarction ventricular tachycardia using a single multilumen catheter

    by Masaya Watanabe, Tadafumi Nannbu, Kazuo Kato, Yuki Ishidoya, Akihiko Yotsukura, Izumi Yoshida


  • Open Access

    Battery Longevity in Modern Implantable Cardioverter‐Defibrillators and Cardiac Resynchronization Therapy‐Defibrillators

    by Kotaro Nishino, Taro Temma, Masaya Watanabe, Motoki Nakao, Masahiro Kawasaki, Kintaro Shimano, Kei Kawakami, Shota Saito, Jiro Koya, Daishiro Tatsuta, et al.

    Background: Battery longevity in high‐voltage devices (HVDs), specifically implantable cardioverter‐defibrillators (ICDs) and cardiac resynchronization therapy‐defibrillators (CRT‐Ds), is critical for reducing the frequency of generator replacements, minimizing procedural risks, and enhancing patient outcomes. Despite technological advancements, significant variability in battery performance remains among the major manufacturers. This study aimed to evaluate the battery longevity among ICDs and CRT‐Ds from the major manufacturers implanted at a single institution and identify the factors influencing battery depletion. Methods: We conducted a retrospective analysis of 353 patients implanted with HVDs (63 Abbott, 150 Boston Scientific, 140 Medtronic) at Hokkaido University Hospital between 2012 and 2021. Kaplan–Meier curves and Cox proportional hazards models were used to analyze the device longevity, with a primary endpoint of the time to battery depletion, defined by the elective replacement indicator. A multivariate analysis adjusted for the potential confounders. Results: Boston Scientific devices exhibited a significantly longer battery life than Abbott and Medtronic devices ( p < 0.001), with a 6‐year replacement‐free survival of 99% for ICDs and 93% for CRT‐Ds. A multivariate analysis identified the device manufacturer, device type (ICD vs. CRT‐D), and ventricular pacing rate as independent predictors of battery depletion ( p < 0.001). Conclusion: Battery longevity differed significantly by the manufacturer, which may influence device selection. Devices with a longer battery life may help reduce the replacement frequency and could potentially contribute to improved patient outcomes and cost‐effectiveness.


  • Open Access

    Survival benefit of primary prevention implantable cardioverter‐defibrillator/cardiac resynchronization therapy with a defibrillator: Analysis of the Japan cardiac device treatment registry and Japanese cardiac registry of heart failure in cardiology

    by Hisashi Yokoshiki, Masaya Watanabe, Sanae Hamaguchi, Hiroyuki Tsutsui, Akihiko Shimizu, Takeshi Mitsuhashi, Kohei Ishibashi, Tomoyuki Kabutoya, Yasuhiro Yoshiga, Yusuke Kondo, et al.

    Background: Evidence supporting the benefit from primary prevention implantable cardioverter‐defibrillator (ICD)/cardiac resynchronization therapy with a defibrillator (CRT‐D) for heart failure with reduced ejection fraction (HFrEF) is scarce in real‐world settings.Methods: We analyzed propensity score matched cohorts of patients eligible for Sudden Cardiac Death in Heart Failure Trial (SCD‐HeFT) from Japan cardiac device treatment registry (JCDTR) and Japanese Cardiac Registry of Heart Failure in Cardiology (JCARE‐CARD). The former served as the defibrillator therapy group and the latter as the conventional therapy group.Results: During an average follow‐up of 24 months, death occurred in 35 of 285 patients (12%) with defibrillator therapy and 65 of 285 patients (23%) with conventional therapy. Adjusted hazard ratios of all‐cause death, sudden death, heart failure death, and noncardiac death in defibrillator versus conventional therapy were 0.616 (95% confidence interval [CI]: 0.402–0.943, p = 0.026), 0.274 (95% CI: 0.103–0.731, p = 0.0097), 0.362 (95% CI: 0.172–0.764, p = 0.0077) and 1.45 (95% CI: 0.711–2.949, p = 0.31). After accounting for death without appropriate defibrillator therapy as a competing risk, the cumulative incidence of first appropriate defibrillator therapy in the defibrillator therapy group was nearly identical to that of all‐cause death in the conventional therapy group. Subgroup analyses indicated a lack of defibrillator benefit in patients with hypertension (p = 0.01 for interaction).Conclusions: Primary prevention ICD/CRT‐D reduced the risk of all‐cause mortality of patients with HFrEF eligible for SCD‐HeFT compared to conventional therapy in the real‐world cohort.


  • Open Access

    Serum Vasoactive Intestinal Peptide as a Novel Biomarker for Low‐Voltage Areas in Patients With Atrial Fibrillation

    by Kotaro Nishino, Taro Temma, Hiroyuki Natsui, Masaya Watanabe, Motoki Nakao, Masahiro Kawasaki, Kintaro Shimano, Kei Kawakami, Shota Saito, Jiro Koya, et al.

    Background: Low‐voltage areas in the left atrium predict atrial fibrillation recurrence after catheter ablation and are associated with adverse outcomes like death, heart failure, and stroke. Detecting low‐voltage areas (LVAs) typically requires invasive procedures, highlighting the need for a simple, minimally invasive marker. Vasoactive intestinal peptide (VIP), a neuropeptide released during parasympathetic stimulation, affects electrophysiological remodeling in atrial fibrillation. We hypothesized that serum VIP could serve as a biomarker for detecting LVAs in these patients. Methods and Results: This prospective, cross‐sectional study was conducted at Hokkaido University Hospital between August 2021 and September 2023. We included 108 patients with atrial fibrillation scheduled for catheter ablation. Blood samples were collected during ablation to measure VIP using an ELISA. Electroanatomical mapping identified LVAs, defined as regions with bipolar voltage ≤0.5 mV and occupying >5% of the left atrial surface. Statistical analyses evaluated the relationship between VIP and LVAs. Fifty‐one patients (47%) had LVAs, with significantly higher serum VIP levels than those without (335.1 versus 247.7 pg/mL, P P <0.001). Conclusions: Serum VIP levels are higher in patients with atrial fibrillation with LVAs, suggesting its potential as a noninvasive biomarker for detecting these areas and improving clinical management.


  • Normalization of increasing shocking coil impedance with full output synchronized shock

    by Takahide Kadosaka, Masaya Watanabe, Motoki Nakao, Taro Koya, Taro Temma, Toshihisa Anzai

    Introduction: Impedance is a crucial parameter in cardiovascular implantable electronic devices (CIEDs). Clinically, most CIEDs measure impedance using low voltage sub‐threshold measurement (LVSM). Although the LVSM of shock impedance (LVSM‐SI) is generally comparable with high voltage shock impedance (HVSI), LVSM‐SI might be inaccurate if peri‐lead tissue degeneration occurs.Methods and Results: We present a case of elevated LVSM‐SI occurring 8 years post‐lead implantation, possibly attributed to encapsulation of the right ventricular lead coil. After 0.1 J shock was delivered, a full output synchronized shock was administered to measure HVSI, revealing a normal value. Furthermore, LVSM‐SI was normalized and maintained within the normal range during long‐term follow‐up.Conclusion: Our findings suggest conducting a full‐output synchronized shock test to assess HVSI when abnormal LVSM‐SI is detected in the remote phase post‐ICD implantation, which may be considered to help normalize LVSM shock impedance.