Evaluation of screw pull-out from plate fixation of en bloc distal radius resection with ulnar reconstruction: Finite element analysis and comparison with experiments on Thiel cadavers
Authors:
Open Access
- 1 June 2025
- journal article
- Published by AIP Publishing in APL Bioengineering
- Vol. 9 (2) , 026123
Abstract
Fractures of the distal radius often require surgical intervention, with plate fixation being a standard stabilization method. Screw loosening and pull-out propose significant complications, necessitating comprehensive understanding of fixation stability factors. This study introduces a novel approach by the combination of finite element analysis (FEA) and experimental investigations on Thiel cadavers to evaluate screw pull-out behavior from plate fixation in en bloc distal radius resection with ulnar reconstruction. In comparison with previous investigations that used computational modeling or fresh-frozen cadaveric specimens, in the present research, FEA predictions specifically experimentally confirm the usage of Thiel cadavers, which better preserve soft tissue elasticity and hydration, thus more closely reflect in vivo conditions. Experimental set-up consisted of bending tests on cadavers and screw pull-out tests in Thiel-cadaveric radius specimens mimicking physiological conditions that induce the effects of screw pull-out. Finite element analysis and simulation were conducted using realistic clinical cases. Biomechanical test results indicated locking-plate deformation and screw loosening, particularly at locations closest to the ulnar bone gap. Torque measurements established various degrees of screw loosening, with the screws closest to the bone gap indicating maximum loosening. FEA demonstrated critical distributions of stresses in screws and locking plates, with good correlations to experimental findings. Screw pull-out force analysis showed vulnerability to loosening, particularly in the area of bone gaps, with findings consistent between biomechanical testing and FEA. This study offers valuable information on the surgical implications and biomechanical considerations of plate fixation for en bloc distal radius resection with ulnar reconstruction.Keywords
Funding Information
- Chulabhorn Royal Academy (FRB660044/0240 Project code 180847)
This publication has 38 references indexed in Scilit:
- Which Treatment is the Best for Giant Cell Tumors of the Distal Radius? A Meta-analysisClinical Orthopaedics and Related Research, 2012
- Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femurBone, 2012
- A Biomechanical Comparison of Volar Locked Plating of Intra-Articular Distal Radius Fractures: Use of 4 Versus 7 Screws for Distal FixationThe Journal of Hand Surgery, 2011
- American Academy of Orthopaedic Surgeons Clinical Practice Guideline onJournal of Bone and Joint Surgery, 2011
- Effects of three different preservation methods on the mechanical properties of human and bovine cortical boneBone, 2010
- The effect of the screw pull-out rate on cortical screw purchase in unreamed and reamed synthetic long bonesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2009
- Modified Ulnar Translocation Technique for the Reconstruction of Giant Cell Tumor of the Distal RadiusOrthopedics, 2008
- The Effect of Pilot Hole Size on the Insertion Torque and Pullout Strength of Self-Tapping Cortical Bone Screws in Osteoporotic BoneJournal of Trauma: Injury, Infection & Critical Care, 2008
- Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-PlateJournal of Orthopaedic Trauma, 2007
- Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine.2001