Evaluation of super-resolution on 50 pancreatic cancer patients with real-time cine MRI from 0.35T MRgRT
- 18 August 2021
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (5) , 055020
Abstract
MR-guided radiotherapy (MRgRT) systems provide excellent soft tissue imaging immediately prior to and in real time during radiation delivery for cancer treatment. However, 2D cine MRI often has limited spatial resolution due to high temporal resolution. This work applies a super resolution machine learning framework to 3.5 mm pixel edge length, low resolution (LR), sagittal 2D cine MRI images acquired on a MRgRT system to generate 0.9 mm pixel edge length, super resolution (SR), images originally acquired at 4 frames per second (FPS). LR images were collected from 50 pancreatic cancer patients treated on a ViewRay MR-LINAC. SR images were evaluated using three methods. 1) The first method utilized intrinsic image quality metrics for evaluation. 2) The second used relative metrics including edge detection and structural similarity index (SSIM). 3) Finally, automatically generated tumor contours were created on both low resolution and super resolution images to evaluate target delineation and compared with DICE and SSIM. Intrinsic image quality metrics all had statistically significant improvements for SR images versus LR images, with mean (±1 SD) BRISQUE scores of 29.65 ± 2.98 and 42.48 ± 0.98 for SR and LR, respectively. SR images showed good agreement with LR images in SSIM evaluation, indicating there was not significant distortion of the images. Comparison of LR and SR images with paired high resolution (HR) 3D images showed that SR images had a mean (±1 SD) SSIM value of 0.633 ± 0.063 and LR a value of 0.587 ± 0.067 (p ≪ 0.05). Contours generated on SR images were also more robust to noise addition than those generated on LR images. This study shows that super resolution with a machine learning framework can generate high spatial resolution images from 4fps low spatial resolution cine MRI acquired on the ViewRay MR-LINAC while maintaining tumor contour quality and without significant acquisition or post processing delay.Keywords
Funding Information
- National Research Foundation of Korea (2020R1A4A101661911)
- Washington University School of Medicine in St. Louis Department of Radiation Oncology
- The Alvin J. Siteman Cancer Center through The Foundation for Barnes-Jewish Hospital and the National Cancer Institute
This publication has 26 references indexed in Scilit:
- Evaluation of ischemic heart disease and viability by cardiac MRIIndian Heart Journal, 2014
- A Generative Model for Resolution Enhancement of Diffusion MRI Data2013
- Super-resolution track-density imaging of thalamic substructures: Comparison with high-resolution anatomical magnetic resonance imaging at 7.0THuman Brain Mapping, 2012
- Super‐resolution methods in MRI: Can they improve the trade‐off between resolution, signal‐to‐noise ratio, and acquisition time?Magnetic Resonance in Medicine, 2012
- Adaptive Radiation TherapyThe Cancer Journal, 2011
- Non-local MRI upsamplingMedical Image Analysis, 2010
- MRI resolution enhancement: How useful are shifted images obtained by changing the demodulation frequency?Magnetic Resonance in Medicine, 2010
- First MR images obtained during megavoltage photon irradiation from a prototype integrated linac‐MR systemMedical Physics, 2009
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Resolution enhancement in MRIMagnetic Resonance Imaging, 2006