Jaehee Chun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jaehee Chun has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
Jin Sung Kim
Oncosoft Inc, 4F,37 Myeongmul Gil, Seoul 03776, South Korea
3 shared publications- Jin Sung Kim
Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications Justin C Park
University of Texas Southwestern Medical Center
3 shared publications- Aashish Chandra Gupta
Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston Texas USA
2 shared publications - Austin Castelo
The University of Texas MD Anderson Cancer Center
2 shared publications - Caleb S. O'COnnor
Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston Texas USA
2 shared publications
Latest Publications
- Open Access
- 15 September 2026
- Published by Wiley in Medical Physics
- Vol. 53 (9) , e70624
Context‐informed personalized segmentation from radiology reports: A fully automated framework for long‐term liver tumor follow‐up
Purpose: Personalized segmentation has been shown to improve performance over generalized models in follow‐up imaging; however, its robustness across large temporal gaps remains unclear. We propose a fully automated, context‐informed personalization framework that integrates radiology report‐derived clinical context with imaging features to improve longitudinal liver tumor segmentation. Methods: This retrospective study included 171 patients for generalized model training and 41 longitudinal patients with follow‐up CT scans acquired 3–15 months after baseline for personalization and evaluation. We developed a U‐Net‐based vision‐language segmentation framework that automatically summarizes free‐text radiology reports, encodes them into language embeddings, and integrates them into intermediate image features to provide clinical context. A generalized model was trained using paired CT‐report data. For each longitudinal patient, personalization was performed at the 3‐month follow‐up using either image‐only input (vision‐only personalization) or paired image–report input (context‐informed personalization). Models were then evaluated on subsequent 6–15‐month follow‐up scans without further adaptation. Patients were stratified into Stable and Dynamic cohorts based on relative GTV volume variability. Performance was assessed using the Dice similarity coefficient (DSC) and LogPenalty Score (LPS), with additional ablation studies examining language models and report components. Results: In the Dynamic cohort, vision‐only personalization exhibited diminishing gains at later follow‐up, whereas context‐informed personalization maintained statistically significant improvements in ΔLPS at 9–15 months ( p < 0.05). In the Stable cohort, both personalization strategies showed sustained performance with comparable segmentation accuracy, indicating that incorporating report‐derived clinical context did not degrade performance in cases with limited anatomical variability. Ablation studies demonstrated that domain‐specific encoder‐based language models (BioClinicalBERT) outperformed larger generative models and that effective context integration did not require complex architectural modifications. Conclusion: Incorporating report‐derived clinical context improves the longitudinal robustness of personalized liver tumor segmentation, particularly in patients with dynamic tumor evolution. These findings suggest that clinically grounded language representations can stabilize personalization across extended follow‐up while enabling fully automated and scalable deployment.
- 15 September 2026
- Published by Wiley in Medical Physics
- Vol. 53 (9) , e70624
Open AccessContext‐informed personalized segmentation from radiology reports: A fully automated framework for long‐term liver tumor follow‐up
Purpose: Personalized segmentation has been shown to improve performance over generalized models in follow‐up imaging; however, its robustness across large temporal gaps remains unclear. We propose a fully automated, context‐informed personalization framework that integrates radiology report‐derived clinical context with imaging features to improve longitudinal liver tumor segmentation. Methods: This retrospective study included 171 patients for generalized model training and 41 longitudinal patients with follow‐up CT scans acquired 3–15 months after baseline for personalization and evaluation. We developed a U‐Net‐based vision‐language segmentation framework that automatically summarizes free‐text radiology reports, encodes them into language embeddings, and integrates them into intermediate image features to provide clinical context. A generalized model was trained using paired CT‐report data. For each longitudinal patient, personalization was performed at the 3‐month follow‐up using either image‐only input (vision‐only personalization) or paired image–report input (context‐informed personalization). Models were then evaluated on subsequent 6–15‐month follow‐up scans without further adaptation. Patients were stratified into Stable and Dynamic cohorts based on relative GTV volume variability. Performance was assessed using the Dice similarity coefficient (DSC) and LogPenalty Score (LPS), with additional ablation studies examining language models and report components. Results: In the Dynamic cohort, vision‐only personalization exhibited diminishing gains at later follow‐up, whereas context‐informed personalization maintained statistically significant improvements in ΔLPS at 9–15 months ( p < 0.05). In the Stable cohort, both personalization strategies showed sustained performance with comparable segmentation accuracy, indicating that incorporating report‐derived clinical context did not degrade performance in cases with limited anatomical variability. Ablation studies demonstrated that domain‐specific encoder‐based language models (BioClinicalBERT) outperformed larger generative models and that effective context integration did not require complex architectural modifications. Conclusion: Incorporating report‐derived clinical context improves the longitudinal robustness of personalized liver tumor segmentation, particularly in patients with dynamic tumor evolution. These findings suggest that clinically grounded language representations can stabilize personalization across extended follow‐up while enabling fully automated and scalable deployment.
- Open Access
- 12 September 2026
- Published by Elsevier in SSRN Electronic Journal
Flash-Radiomics: A Scalable Hybrid CPU–CUDA Engine for Standardized Scalar Radiomics and Accelerated Spatial Mapping
Background and Objectives: Spatial mapping retains the spatial distribution of radiomic features, but computational cost and fragmented software limit its use. We developed Flash-Radiomics with scalar extraction and spatial mapping, a central processing unit (CPU) backend, a hybrid Compute Unified Device Architecture (CUDA) backend, consistent feature names, and Hierarchical Data Format version 5 (HDF5) storage.Methods: We evaluated Image Biomarker Standardisation Initiative (IBSI) compliance, CPU-CUDA concordance, and end-to-end processing time. Compliance testing included 825 chapter 1 (IBSI-1) tests covering 165 high-consensus features and 323 chapter 2 (IBSI-2) tests with numerical references. Concordance testing included 1,148 scalar pairs and 93 spatial-map pairs. End-to-end processing time was measured five times per input volume of interest (VOI) size. Comparisons included the Medical Image Radiomics Processor (MIRP) and PyRadiomics for 102 shared scalar features and PyRadiomics for 93 shared spatial maps.Results: Both backends passed all 1,148 IBSI tests, and all paired results were concordant. At the largest scalar input, CPU required 76.343 s and hybrid CUDA 81.915 s; CPU was 4.7 times faster than MIRP and 190.7 times faster than PyRadiomics. At the largest spatial input completed by both backends, hybrid CUDA reduced processing time by 68.6% relative to CPU (79.280 versus 252.791 s). At PyRadiomics' largest completed spatial input, hybrid CUDA was 84.9 times faster.Conclusions: Flash-Radiomics unified standardized scalar extraction, spatial mapping, concordant CPU-CUDA results, and HDF5 storage. CPU processing time was similar or shorter for scalar extraction, whereas hybrid CUDA was faster for spatial mapping under the tested conditions.
- 12 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFlash-Radiomics: A Scalable Hybrid CPU–CUDA Engine for Standardized Scalar Radiomics and Accelerated Spatial Mapping
Background and Objectives: Spatial mapping retains the spatial distribution of radiomic features, but computational cost and fragmented software limit its use. We developed Flash-Radiomics with scalar extraction and spatial mapping, a central processing unit (CPU) backend, a hybrid Compute Unified Device Architecture (CUDA) backend, consistent feature names, and Hierarchical Data Format version 5 (HDF5) storage.Methods: We evaluated Image Biomarker Standardisation Initiative (IBSI) compliance, CPU-CUDA concordance, and end-to-end processing time. Compliance testing included 825 chapter 1 (IBSI-1) tests covering 165 high-consensus features and 323 chapter 2 (IBSI-2) tests with numerical references. Concordance testing included 1,148 scalar pairs and 93 spatial-map pairs. End-to-end processing time was measured five times per input volume of interest (VOI) size. Comparisons included the Medical Image Radiomics Processor (MIRP) and PyRadiomics for 102 shared scalar features and PyRadiomics for 93 shared spatial maps.Results: Both backends passed all 1,148 IBSI tests, and all paired results were concordant. At the largest scalar input, CPU required 76.343 s and hybrid CUDA 81.915 s; CPU was 4.7 times faster than MIRP and 190.7 times faster than PyRadiomics. At the largest spatial input completed by both backends, hybrid CUDA reduced processing time by 68.6% relative to CPU (79.280 versus 252.791 s). At PyRadiomics' largest completed spatial input, hybrid CUDA was 84.9 times faster.Conclusions: Flash-Radiomics unified standardized scalar extraction, spatial mapping, concordant CPU-CUDA results, and HDF5 storage. CPU processing time was similar or shorter for scalar extraction, whereas hybrid CUDA was faster for spatial mapping under the tested conditions.
- Open Access
- 21 December 2025
- Published by Wiley in Medical Physics
- Vol. 53 (1) , e70206
Uncertainty‐guided test‐time optimization for personalizing segmentation models in longitudinal medical imaging
Background: Accurate and consistent image segmentation across longitudinal scans is essential in many clinical applications, including surveillance, treatment monitoring, and adaptive interventions. While personalized model adaptation using patient‐specific prior scans has shown promise, current approaches typically rely on fixed training durations and lack mechanisms to determine optimal stopping points on a per‐patient basis, particularly in the absence of validation labels. Purpose: We propose an uncertainty‐guided test‐time optimization (TTO) framework that dynamically adjusts the personalization duration for each patient using a validation‐free stopping criterion based on predictive uncertainty. Methods: Our framework personalizes a generalized segmentation model using patient‐specific prior imaging and selects the optimal checkpoint based on the minimum voxel‐wise predictive uncertainty, estimated via Monte Carlo Dropout (TTO‐MCD) or Deep Ensembling (TTO‐DE). We evaluated the approach on three datasets: 214 pancreas (CT) scans, 243 liver (CT) scans, and 175 head‐and‐neck tumor (MRI) scans, each containing a subset of patients with paired longitudinal scans to enable patient‐specific personalization. Each patient's follow‐up scan was held out for testing. As a baseline, we implemented a fixed‐epoch personalization strategy (Pre‐TTO) using a fivefold cross‐test design to emulate deployable model selection without test label leakage. Results: TTO methods consistently outperformed the Pre‐TTO and unpersonalized baseline across standard metrics, including the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance (HD95), Mean Surface Distance (MSD), and the proposed LogPenalty Score (LPS), which provides a bounded, interpretable scale that jointly reflects volumetric and boundary fidelity. Paired t ‐tests confirmed statistically significant improvements for pancreas and liver datasets ( p < 0.05), while favorable trends were observed in the head‐and‐neck dataset despite greater anatomical variability. Both TTO‐MCD and TTO‐DE achieved near‐optimal performance without requiring access to labels at test time. Conclusion: Uncertainty‐guided TTO provides a robust, validation‐free strategy for optimizing patient‐specific segmentation models in longitudinal medical imaging. By tailoring personalization based on predictive uncertainty, our method improves segmentation quality across a range of imaging modalities and anatomical targets. This framework supports broad clinical deployment of personalized AI and motivates future extensions to contextual integration and multi‐label segmentation. Code is publicly available at https://github.com/jchun‐ai/uncertainty‐tto .
- 21 December 2025
- Published by Wiley in Medical Physics
- Vol. 53 (1) , e70206
Open AccessUncertainty‐guided test‐time optimization for personalizing segmentation models in longitudinal medical imaging
Background: Accurate and consistent image segmentation across longitudinal scans is essential in many clinical applications, including surveillance, treatment monitoring, and adaptive interventions. While personalized model adaptation using patient‐specific prior scans has shown promise, current approaches typically rely on fixed training durations and lack mechanisms to determine optimal stopping points on a per‐patient basis, particularly in the absence of validation labels. Purpose: We propose an uncertainty‐guided test‐time optimization (TTO) framework that dynamically adjusts the personalization duration for each patient using a validation‐free stopping criterion based on predictive uncertainty. Methods: Our framework personalizes a generalized segmentation model using patient‐specific prior imaging and selects the optimal checkpoint based on the minimum voxel‐wise predictive uncertainty, estimated via Monte Carlo Dropout (TTO‐MCD) or Deep Ensembling (TTO‐DE). We evaluated the approach on three datasets: 214 pancreas (CT) scans, 243 liver (CT) scans, and 175 head‐and‐neck tumor (MRI) scans, each containing a subset of patients with paired longitudinal scans to enable patient‐specific personalization. Each patient's follow‐up scan was held out for testing. As a baseline, we implemented a fixed‐epoch personalization strategy (Pre‐TTO) using a fivefold cross‐test design to emulate deployable model selection without test label leakage. Results: TTO methods consistently outperformed the Pre‐TTO and unpersonalized baseline across standard metrics, including the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance (HD95), Mean Surface Distance (MSD), and the proposed LogPenalty Score (LPS), which provides a bounded, interpretable scale that jointly reflects volumetric and boundary fidelity. Paired t ‐tests confirmed statistically significant improvements for pancreas and liver datasets ( p < 0.05), while favorable trends were observed in the head‐and‐neck dataset despite greater anatomical variability. Both TTO‐MCD and TTO‐DE achieved near‐optimal performance without requiring access to labels at test time. Conclusion: Uncertainty‐guided TTO provides a robust, validation‐free strategy for optimizing patient‐specific segmentation models in longitudinal medical imaging. By tailoring personalization based on predictive uncertainty, our method improves segmentation quality across a range of imaging modalities and anatomical targets. This framework supports broad clinical deployment of personalized AI and motivates future extensions to contextual integration and multi‐label segmentation. Code is publicly available at https://github.com/jchun‐ai/uncertainty‐tto .
- Open Access
- 30 August 2024
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 32, 100273
Optimized needle configuration for operational seed (ONCOSEED) efficiency and deployment for prostate seed implants
- 30 August 2024
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 32, 100273
Open AccessOptimized needle configuration for operational seed (ONCOSEED) efficiency and deployment for prostate seed implants
- Open Access
- 12 September 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (18) , 185012
OpenKBP-Opt: an international and reproducible evaluation of 76 knowledge-based planning pipelines
Objective. To establish an open framework for developing plan optimization models for knowledge-based planning (KBP). Approach. Our framework includes radiotherapy treatment data (i.e. reference plans) for 100 patients with head-and-neck cancer who were treated with intensity-modulated radiotherapy. That data also includes high-quality dose predictions from 19 KBP models that were developed by different research groups using out-of-sample data during the OpenKBP Grand Challenge. The dose predictions were input to four fluence-based dose mimicking models to form 76 unique KBP pipelines that generated 7600 plans (76 pipelines × 100 patients). The predictions and KBP-generated plans were compared to the reference plans via: the dose score, which is the average mean absolute voxel-by-voxel difference in dose; the deviation in dose-volume histogram (DVH) points; and the frequency of clinical planning criteria satisfaction. We also performed a theoretical investigation to justify our dose mimicking models. Main results. The range in rank order correlation of the dose score between predictions and their KBP pipelines was 0.50–0.62, which indicates that the quality of the predictions was generally positively correlated with the quality of the plans. Additionally, compared to the input predictions, the KBP-generated plans performed significantly better ( P < 0.05; one-sided Wilcoxon test) on 18 of 23 DVH points. Similarly, each optimization model generated plans that satisfied a higher percentage of criteria than the reference plans, which satisfied 3.5% more criteria than the set of all dose predictions. Lastly, our theoretical investigation demonstrated that the dose mimicking models generated plans that are also optimal for an inverse planning model. Significance. This was the largest international effort to date for evaluating the combination of KBP prediction and optimization models. We found that the best performing models significantly outperformed the reference dose and dose predictions. In the interest of reproducibility, our data and code is freely available.
- 12 September 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (18) , 185012
Open AccessOpenKBP-Opt: an international and reproducible evaluation of 76 knowledge-based planning pipelines
Objective. To establish an open framework for developing plan optimization models for knowledge-based planning (KBP). Approach. Our framework includes radiotherapy treatment data (i.e. reference plans) for 100 patients with head-and-neck cancer who were treated with intensity-modulated radiotherapy. That data also includes high-quality dose predictions from 19 KBP models that were developed by different research groups using out-of-sample data during the OpenKBP Grand Challenge. The dose predictions were input to four fluence-based dose mimicking models to form 76 unique KBP pipelines that generated 7600 plans (76 pipelines × 100 patients). The predictions and KBP-generated plans were compared to the reference plans via: the dose score, which is the average mean absolute voxel-by-voxel difference in dose; the deviation in dose-volume histogram (DVH) points; and the frequency of clinical planning criteria satisfaction. We also performed a theoretical investigation to justify our dose mimicking models. Main results. The range in rank order correlation of the dose score between predictions and their KBP pipelines was 0.50–0.62, which indicates that the quality of the predictions was generally positively correlated with the quality of the plans. Additionally, compared to the input predictions, the KBP-generated plans performed significantly better ( P < 0.05; one-sided Wilcoxon test) on 18 of 23 DVH points. Similarly, each optimization model generated plans that satisfied a higher percentage of criteria than the reference plans, which satisfied 3.5% more criteria than the set of all dose predictions. Lastly, our theoretical investigation demonstrated that the dose mimicking models generated plans that are also optimal for an inverse planning model. Significance. This was the largest international effort to date for evaluating the combination of KBP prediction and optimization models. We found that the best performing models significantly outperformed the reference dose and dose predictions. In the interest of reproducibility, our data and code is freely available.
- 24 May 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (11) , 115009
Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling
Objective. Real-time imaging is highly desirable in image-guided radiotherapy, as it provides instantaneous knowledge of patients’ anatomy and motion during treatments and enables online treatment adaptation to achieve the highest tumor targeting accuracy. Due to extremely limited acquisition time, only one or few x-ray projections can be acquired for real-time imaging, which poses a substantial challenge to localize the tumor from the scarce projections. For liver radiotherapy, such a challenge is further exacerbated by the diminished contrast between the tumor and the surrounding normal liver tissues. Here, we propose a framework combining graph neural network-based deep learning and biomechanical modeling to track liver tumor in real-time from a single onboard x-ray projection. Approach. Liver tumor tracking is achieved in two steps. First, a deep learning network is developed to predict the liver surface deformation using image features learned from the x-ray projection. Second, the intra-liver deformation is estimated through biomechanical modeling, using the liver surface deformation as the boundary condition to solve tumor motion by finite element analysis. The accuracy of the proposed framework was evaluated using a dataset of 10 patients with liver cancer. Main results. The results show accurate liver surface registration from the graph neural network-based deep learning model, which translates into accurate, fiducial-less liver tumor localization after biomechanical modeling (Significance. The method demonstrates its potentiality towards intra-treatment and real-time 3D liver tumor monitoring and localization. It could be applied to facilitate 4D dose accumulation, multi-leaf collimator tracking and real-time plan adaptation. The method can be adapted to other anatomical sites as well.
- 24 May 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (11) , 115009
Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling
Objective. Real-time imaging is highly desirable in image-guided radiotherapy, as it provides instantaneous knowledge of patients’ anatomy and motion during treatments and enables online treatment adaptation to achieve the highest tumor targeting accuracy. Due to extremely limited acquisition time, only one or few x-ray projections can be acquired for real-time imaging, which poses a substantial challenge to localize the tumor from the scarce projections. For liver radiotherapy, such a challenge is further exacerbated by the diminished contrast between the tumor and the surrounding normal liver tissues. Here, we propose a framework combining graph neural network-based deep learning and biomechanical modeling to track liver tumor in real-time from a single onboard x-ray projection. Approach. Liver tumor tracking is achieved in two steps. First, a deep learning network is developed to predict the liver surface deformation using image features learned from the x-ray projection. Second, the intra-liver deformation is estimated through biomechanical modeling, using the liver surface deformation as the boundary condition to solve tumor motion by finite element analysis. The accuracy of the proposed framework was evaluated using a dataset of 10 patients with liver cancer. Main results. The results show accurate liver surface registration from the graph neural network-based deep learning model, which translates into accurate, fiducial-less liver tumor localization after biomechanical modeling (Significance. The method demonstrates its potentiality towards intra-treatment and real-time 3D liver tumor monitoring and localization. It could be applied to facilitate 4D dose accumulation, multi-leaf collimator tracking and real-time plan adaptation. The method can be adapted to other anatomical sites as well.
- Open Access
Deep-Learning-Based Automatic Detection and Segmentation of Brain Metastases with Small Volume for Stereotactic Ablative Radiotherapy
Recently, several efforts have been made to develop the deep learning (DL) algorithms for automatic detection and segmentation of brain metastases (BM). In this study, we developed an advanced DL model to BM detection and segmentation, especially for small-volume BM. From the institutional cancer registry, contrast-enhanced magnetic resonance images of 65 patients and 603 BM were collected to train and evaluate our DL model. Of the 65 patients, 12 patients with 58 BM were assigned to test-set for performance evaluation. Ground-truth for BM was assigned to one radiation oncologist to manually delineate BM and another one to cross-check. Unlike other previous studies, our study dealt with relatively small BM, so the area occupied by the BM in the high-resolution images were small. Our study applied training techniques such as the overlapping patch technique and 2.5-dimensional (2.5D) training to the well-known U-Net architecture to learn better in smaller BM. As a DL architecture, 2D U-Net was utilized by 2.5D training. For better efficacy and accuracy of a two-dimensional U-Net, we applied effective preprocessing include 2.5D overlapping patch technique. The sensitivity and average false positive rate were measured as detection performance, and their values were 97% and 1.25 per patient, respectively. The dice coefficient with dilation and 95% Hausdorff distance were measured as segmentation performance, and their values were 75% and 2.057 mm, respectively. Our DL model can detect and segment BM with small volume with good performance. Our model provides considerable benefit for clinicians with automatic detection and segmentation of BM for stereotactic ablative radiotherapy.
Open AccessDeep-Learning-Based Automatic Detection and Segmentation of Brain Metastases with Small Volume for Stereotactic Ablative Radiotherapy
Recently, several efforts have been made to develop the deep learning (DL) algorithms for automatic detection and segmentation of brain metastases (BM). In this study, we developed an advanced DL model to BM detection and segmentation, especially for small-volume BM. From the institutional cancer registry, contrast-enhanced magnetic resonance images of 65 patients and 603 BM were collected to train and evaluate our DL model. Of the 65 patients, 12 patients with 58 BM were assigned to test-set for performance evaluation. Ground-truth for BM was assigned to one radiation oncologist to manually delineate BM and another one to cross-check. Unlike other previous studies, our study dealt with relatively small BM, so the area occupied by the BM in the high-resolution images were small. Our study applied training techniques such as the overlapping patch technique and 2.5-dimensional (2.5D) training to the well-known U-Net architecture to learn better in smaller BM. As a DL architecture, 2D U-Net was utilized by 2.5D training. For better efficacy and accuracy of a two-dimensional U-Net, we applied effective preprocessing include 2.5D overlapping patch technique. The sensitivity and average false positive rate were measured as detection performance, and their values were 97% and 1.25 per patient, respectively. The dice coefficient with dilation and 95% Hausdorff distance were measured as segmentation performance, and their values were 75% and 2.057 mm, respectively. Our DL model can detect and segment BM with small volume with good performance. Our model provides considerable benefit for clinicians with automatic detection and segmentation of BM for stereotactic ablative radiotherapy.
- 1 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (20) , 204001
Abdominal synthetic CT reconstruction with intensity projection prior for MRI-only adaptive radiotherapy
Objective . Owing to the superior soft tissue contrast of MRI, MRI-guided adaptive radiotherapy (ART) is well-suited to managing interfractional changes in anatomy. An MRI-only workflow is desirable, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that is well suited to handling intestinal gas in abdominal MRI-only ART. Approach . We utilize a paired data DL approach enabled by the intensity projection prior, in which well-matching training pairs are created by propagating air from MRI to corresponding CT scans. Evaluations focus on two classes: patients with (1) little involvement of intestinal gas, and (2) notable differences in intestinal gas presence between corresponding scans. Comparisons between sCT-based plans and CT-based clinical plans for both classes are made at the first treatment fraction to highlight the dosimetric impact of the variable presence of intestinal gas. Main results . Class 1 patients ( n = 13) demonstrate differences in prescribed dose coverage of the PTV of 1.3 ± 2.1% between clinical plans and sCT-based plans. Mean DVH differences in all structures for Class 1 patients are found to be statistically insignificant. In Class 2 ( n = 20), target coverage is 13.3 ± 11.0% higher in the clinical plans and mean DVH differences are found to be statistically significant. Significance . Significant deviations in calculated doses arising from the variable presence of intestinal gas in corresponding CT and MRI scans result in uncertainty in high-dose regions that may limit the effectiveness of adaptive dose escalation efforts. We have proposed a paired data-driven DL approach to sCT reconstruction for accurate dose calculations in abdominal ART enabled by the creation of a clinically unavailable training data set with well-matching representations of intestinal gas.
- 1 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (20) , 204001
Abdominal synthetic CT reconstruction with intensity projection prior for MRI-only adaptive radiotherapy
Objective . Owing to the superior soft tissue contrast of MRI, MRI-guided adaptive radiotherapy (ART) is well-suited to managing interfractional changes in anatomy. An MRI-only workflow is desirable, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that is well suited to handling intestinal gas in abdominal MRI-only ART. Approach . We utilize a paired data DL approach enabled by the intensity projection prior, in which well-matching training pairs are created by propagating air from MRI to corresponding CT scans. Evaluations focus on two classes: patients with (1) little involvement of intestinal gas, and (2) notable differences in intestinal gas presence between corresponding scans. Comparisons between sCT-based plans and CT-based clinical plans for both classes are made at the first treatment fraction to highlight the dosimetric impact of the variable presence of intestinal gas. Main results . Class 1 patients ( n = 13) demonstrate differences in prescribed dose coverage of the PTV of 1.3 ± 2.1% between clinical plans and sCT-based plans. Mean DVH differences in all structures for Class 1 patients are found to be statistically insignificant. In Class 2 ( n = 20), target coverage is 13.3 ± 11.0% higher in the clinical plans and mean DVH differences are found to be statistically significant. Significance . Significant deviations in calculated doses arising from the variable presence of intestinal gas in corresponding CT and MRI scans result in uncertainty in high-dose regions that may limit the effectiveness of adaptive dose escalation efforts. We have proposed a paired data-driven DL approach to sCT reconstruction for accurate dose calculations in abdominal ART enabled by the creation of a clinically unavailable training data set with well-matching representations of intestinal gas.
- 18 August 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (5) , 055020
Evaluation of super-resolution on 50 pancreatic cancer patients with real-time cine MRI from 0.35T MRgRT
MR-guided radiotherapy (MRgRT) systems provide excellent soft tissue imaging immediately prior to and in real time during radiation delivery for cancer treatment. However, 2D cine MRI often has limited spatial resolution due to high temporal resolution. This work applies a super resolution machine learning framework to 3.5 mm pixel edge length, low resolution (LR), sagittal 2D cine MRI images acquired on a MRgRT system to generate 0.9 mm pixel edge length, super resolution (SR), images originally acquired at 4 frames per second (FPS). LR images were collected from 50 pancreatic cancer patients treated on a ViewRay MR-LINAC. SR images were evaluated using three methods. 1) The first method utilized intrinsic image quality metrics for evaluation. 2) The second used relative metrics including edge detection and structural similarity index (SSIM). 3) Finally, automatically generated tumor contours were created on both low resolution and super resolution images to evaluate target delineation and compared with DICE and SSIM. Intrinsic image quality metrics all had statistically significant improvements for SR images versus LR images, with mean (±1 SD) BRISQUE scores of 29.65 ± 2.98 and 42.48 ± 0.98 for SR and LR, respectively. SR images showed good agreement with LR images in SSIM evaluation, indicating there was not significant distortion of the images. Comparison of LR and SR images with paired high resolution (HR) 3D images showed that SR images had a mean (±1 SD) SSIM value of 0.633 ± 0.063 and LR a value of 0.587 ± 0.067 (p ≪ 0.05). Contours generated on SR images were also more robust to noise addition than those generated on LR images. This study shows that super resolution with a machine learning framework can generate high spatial resolution images from 4fps low spatial resolution cine MRI acquired on the ViewRay MR-LINAC while maintaining tumor contour quality and without significant acquisition or post processing delay.
- 18 August 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (5) , 055020
Evaluation of super-resolution on 50 pancreatic cancer patients with real-time cine MRI from 0.35T MRgRT
MR-guided radiotherapy (MRgRT) systems provide excellent soft tissue imaging immediately prior to and in real time during radiation delivery for cancer treatment. However, 2D cine MRI often has limited spatial resolution due to high temporal resolution. This work applies a super resolution machine learning framework to 3.5 mm pixel edge length, low resolution (LR), sagittal 2D cine MRI images acquired on a MRgRT system to generate 0.9 mm pixel edge length, super resolution (SR), images originally acquired at 4 frames per second (FPS). LR images were collected from 50 pancreatic cancer patients treated on a ViewRay MR-LINAC. SR images were evaluated using three methods. 1) The first method utilized intrinsic image quality metrics for evaluation. 2) The second used relative metrics including edge detection and structural similarity index (SSIM). 3) Finally, automatically generated tumor contours were created on both low resolution and super resolution images to evaluate target delineation and compared with DICE and SSIM. Intrinsic image quality metrics all had statistically significant improvements for SR images versus LR images, with mean (±1 SD) BRISQUE scores of 29.65 ± 2.98 and 42.48 ± 0.98 for SR and LR, respectively. SR images showed good agreement with LR images in SSIM evaluation, indicating there was not significant distortion of the images. Comparison of LR and SR images with paired high resolution (HR) 3D images showed that SR images had a mean (±1 SD) SSIM value of 0.633 ± 0.063 and LR a value of 0.587 ± 0.067 (p ≪ 0.05). Contours generated on SR images were also more robust to noise addition than those generated on LR images. This study shows that super resolution with a machine learning framework can generate high spatial resolution images from 4fps low spatial resolution cine MRI acquired on the ViewRay MR-LINAC while maintaining tumor contour quality and without significant acquisition or post processing delay.
- Open Access
- 14 June 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (6) , e0253204
Evaluation of Computer-Aided Nodule Assessment and Risk Yield (CANARY) in Korean patients for prediction of invasiveness of ground-glass opacity nodule
Differentiating the invasiveness of ground-glass nodules (GGN) is clinically important, and several institutions have attempted to develop their own solutions by using computed tomography images. The purpose of this study is to evaluate Computer-Aided Analysis of Risk Yield (CANARY), a validated virtual biopsy and risk-stratification machine-learning tool for lung adenocarcinomas, in a Korean patient population. To this end, a total of 380 GGNs from 360 patients who underwent pulmonary resection in a single institution were reviewed. Based on the Score Indicative of Lung Cancer Aggression (SILA), a quantitative indicator of CANARY analysis results, all of the GGNs were classified as “indolent” (atypical adenomatous hyperplasia, adenocarcinomas in situ, or minimally invasive adenocarcinoma) or “invasive” (invasive adenocarcinoma) and compared with the pathology reports. By considering the possibility of uneven class distribution, statistical analysis was performed on the 1) entire cohort and 2) randomly extracted six sets of class-balanced samples. For each trial, the optimal cutoff SILA was obtained from the receiver operating characteristic curve. The classification results were evaluated using several binary classification metrics. Of a total of 380 GGNs, the mean SILA for 65 (17.1%) indolent and 315 (82.9%) invasive lesions were 0.195±0.124 and 0.391±0.208 (p < 0.0001). The area under the curve (AUC) of each trial was 0.814 and 0.809, with an optimal threshold SILA of 0.229 for both. The macro F1-score and geometric mean were found to be 0.675 and 0.745 for the entire cohort, while both scored 0.741 in the class-equalized dataset. From these results, CANARY could be confirmed acceptable in classifying GGN for Korean patients after the cutoff SILA was calibrated. We found that adjusting the cutoff SILA is needed to use CANARY in other countries or races, and geometric mean could be more objective than F1-score or AUC in the binary classification of imbalanced data.
- 14 June 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (6) , e0253204
Open AccessEvaluation of Computer-Aided Nodule Assessment and Risk Yield (CANARY) in Korean patients for prediction of invasiveness of ground-glass opacity nodule
Differentiating the invasiveness of ground-glass nodules (GGN) is clinically important, and several institutions have attempted to develop their own solutions by using computed tomography images. The purpose of this study is to evaluate Computer-Aided Analysis of Risk Yield (CANARY), a validated virtual biopsy and risk-stratification machine-learning tool for lung adenocarcinomas, in a Korean patient population. To this end, a total of 380 GGNs from 360 patients who underwent pulmonary resection in a single institution were reviewed. Based on the Score Indicative of Lung Cancer Aggression (SILA), a quantitative indicator of CANARY analysis results, all of the GGNs were classified as “indolent” (atypical adenomatous hyperplasia, adenocarcinomas in situ, or minimally invasive adenocarcinoma) or “invasive” (invasive adenocarcinoma) and compared with the pathology reports. By considering the possibility of uneven class distribution, statistical analysis was performed on the 1) entire cohort and 2) randomly extracted six sets of class-balanced samples. For each trial, the optimal cutoff SILA was obtained from the receiver operating characteristic curve. The classification results were evaluated using several binary classification metrics. Of a total of 380 GGNs, the mean SILA for 65 (17.1%) indolent and 315 (82.9%) invasive lesions were 0.195±0.124 and 0.391±0.208 (p < 0.0001). The area under the curve (AUC) of each trial was 0.814 and 0.809, with an optimal threshold SILA of 0.229 for both. The macro F1-score and geometric mean were found to be 0.675 and 0.745 for the entire cohort, while both scored 0.741 in the class-equalized dataset. From these results, CANARY could be confirmed acceptable in classifying GGN for Korean patients after the cutoff SILA was calibrated. We found that adjusting the cutoff SILA is needed to use CANARY in other countries or races, and geometric mean could be more objective than F1-score or AUC in the binary classification of imbalanced data.