Imaging Peptide and Protein Chirality via Amino Acid Analysis by Chiral × Chiral Two-Dimensional Correlation Liquid Chromatography
Authors:
- 6 June 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (13) , 7963-7971
Abstract
The present contribution illustrates the utilization of a chiral × chiral two dimensional liquid chromatography (2DLC) setup with tert-butylcarbamoyl quinine chiral stationary phase (CSP) in the first dimension (1D) and tert-butylcarbamoyl quinidine CSP in the second dimension (2D) to analyze FMOC-derivatized D and L amino acids from peptide hydrolysates. Hereby, in the 1D and 2D chiral separation dimensions factors such as selector and immobilization chemistry of the CSPs, mobile phase, temperature, column hardware dimensions, stationary phase supports, particle type and packing were identical. Orthogonality between 1D and 2D CSPs was solely based on their stereochemistry i.e. their opposite configurations in two chiral centers of the selector molecules, which results in inversion of enantiomer elution orders in the two dimensions. Using Coreshell CSPs for fast chromatography allowed 2D-flow rates which were 60 times faster than the 1D-flow rates to enable online comprehensive two-dimensional chromatography (LC×LC). Due to very similar chemoselectivity, yet opposite elution orders of corresponding enantiomers in 1D and 2D, characteristic 2D-elution patterns for achiral and chiral components can be generated. Peaks of achiral components and impurities are lined up on the diagonal line in the 2D separation space (contour plot) and thereby removed from the chromatographic space of the target enantiomers avoiding overlaps with potential interferences. Corresponding enantiomers provide cross peaks on the 2D chromatogram. Moreover, enantioselectivity of both single CSPs is combined to result in an enhanced overall 2D enantioselectivity. The concept is illustrated for the therapeutic peptides gramicidin and bacitracin. Since all amino acids give a consistent elution order as FMOC-derivatives, all enantiomers of the same configuration are either above or below the diagonal line allowing straightforward imaging of the configuration of the amino acids in peptides by the 2D chromatogram.Keywords
Funding Information
- Agilent Technologies
This publication has 48 references indexed in Scilit:
- Rapid Determination of Chiral Amino Acids by LC-Q-TOF Mass SpectrometryBulletin of the Korean Chemical Society, 2011
- Synergistic Effects on Enantioselectivity of Zwitterionic Chiral Stationary Phases for Separations of Chiral Acids, Bases, and Amino Acids by HPLCAnalytical Chemistry, 2008
- Application of chiral derivatizing agents in the high-performance liquid chromatographic separation of amino acid enantiomers: A reviewJournal of Pharmaceutical and Biomedical Analysis, 2008
- Fast, comprehensive two-dimensional liquid chromatographyJournal of Chromatography A, 2007
- The gramicidin ion channel: A model membrane proteinBiochimica et Biophysica Acta (BBA) - Biomembranes, 2007
- Combination of HPLC “Inverted Chirality Columns Approach” and MS/MS Detection for Extreme Enantiomeric Excess Determination Even in Absence of Reference Samples. Application to Camptothecin DerivativesAnalytical Chemistry, 2007
- Orthogonality of Separation in Two-Dimensional Liquid ChromatographyAnalytical Chemistry, 2005
- Marfey?s reagent for chiral amino acid analysis: A reviewAmino Acids, 2004
- Analysis of Amino Acids by High-Performance Liquid Chromatography with Circular Dichroism Detection.Chemical and Pharmaceutical Bulletin, 1995
- High recovery of tryptophan from acid hydrolysates of proteinsBiochemical and Biophysical Research Communications, 1969