Patient‐specific in vitro testing for evaluating TAVR clinical performance—A complementary approach to current ISO standard testing
- 7 December 2020
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 45 (4) , E41-E52
Abstract
Following in vitro tests established for surgical prosthetic heart valves, transcatheter aortic valves (TAV) are similarly tested in idealized geometries—excluding effects that may hamper TAVR performance in situ. Testing in vitro in pulse duplicator systems that incorporated patient‐specific replicas would enhance the testing veracity by bringing it closer to the clinical scenario. To that end we compare TAV hemodynamic performance tested in idealized geometries according to the ISO standard (baseline performance) to that obtained by testing the TAVs following deployment in patient‐specific replicas. Balloon‐expandable (n = 2) and self‐expandable (n = 3) TAVs were tested in an idealized geometry in mock‐circulation system (following ISO 5840‐3 guidelines) and compared to the measurements in a dedicated mock‐circulation system adapted for the five patient‐specific replicas. Patient‐specific deployments resulted in a decline in performance as compared to the baseline idealized testing, as well as a variation in performance that depended on the design features of each device that was further correlated with the radial expansion and eccentricity of the deployed TAV stent (obtained with CT‐scans of the deployed valves). By excluding the deployment effects in irregular geometries, the current idealized ISO testing is limited to characterize the baseline device performance. Utilizing patient‐specific anatomic contours provides performance indicators under more stringent conditions likely encountered in vivo. It has the potential to enhance testing and development complementary to the ISO standard, for improved TAV safety and effectiveness.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (STTR R41‐HL134418)
- National Institute of Biomedical Imaging and Bioengineering (1U01EB026414‐01)
This publication has 26 references indexed in Scilit:
- Calcific aortic stenosisNature Reviews Disease Primers, 2016
- Prosthesis–Patient Mismatch After Transcatheter Aortic Valve ImplantationThe Annals of Thoracic Surgery, 2016
- Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve ReplacementJournal of the American Heart Association, 2016
- New Braile Inovare transcatheter aortic prosthesis: clinical results and follow-upEuroIntervention, 2015
- Calcification in Aortic StenosisJACC, 2015
- Assessment of Paravalvular Regurgitation Following TAVRJACC: Cardiovascular Imaging, 2015
- In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart ValveJournal of Biomechanical Engineering, 2013
- Aortic Valve Calcification as an Incidental Finding at CT of the Elderly: Severity and Location as Predictors of Aortic StenosisAmerican Journal of Roentgenology, 2006
- Body surface area as a predictor of aortic and pulmonary valve diameterThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Patterns of calcific deposits in operatively excised stenotic or purely regurgitant aortic valves and their relation to mechanical stressThe American Journal of Cardiology, 1986