One-year follow-up of a multifocal intraocular lens with optimized elevated phase shift
- 1 October 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (10) , 1018-1024
Abstract
Purpose: To evaluate the standard outcomes of a multifocal intraocular lens (MIOL) with optimized elevated phase shift (EPS). Setting: (“Masked by journal requirement”) Design: Retrospective observational. Methods: 41 patients, consecutively operated on cataracts or refractive lens exchange with the implantation of the Liberty 640PM (EPS 2.0) and followed during 12-months, were included in the analysis. Retrieved variables were visual acuities at far, intermediate and near distances, defocus curves (VADC), and prediction error of four formulas optimized for IOL Master 500 and Pentacam AXL Wave. Patient reported outcomes were also obtained for assessing spectacle independence, satisfaction, bothersome to dysphotopsia, difficulties in daily life tasks and decision to be operated with the same MIOL. Results: Median monocular efficacy with best distance correction was 0, 0.1 and 0.1 logMAR at far, intermediate and near distances, respectively, with patients achieving binocularly a median of 0 logMAR at the three distances. VADC showed a depth of field of 3 D above 0.2 logMAR with a median increase of 0.07 logMAR from -1.5 D to -2.5 D. Complete spectacle independence was achieved at far distance whereas 97.6% and 85.4% was achieved at intermediate and near distances, respectively. 7.3% of patients were bothered by dysphotopsia and 92.6% of patients were likely to be operated again. Conclusions: EPS 2.0 restored patient’s vision in the full range of field with a nearly monotone decrease of visual performance from far to near, achieving high rates of spectacle independence at all distances and with low positive dysphotopsia rates ( ClinicalTrials.gov Identifier: NCT05735990).Keywords
This publication has 31 references indexed in Scilit:
- Comparative Evaluation of Visual Outcomes After Bilateral Implantation of a Diffractive Trifocal Intraocular Lens and an Extended Depth of Focus Intraocular LensEye & Contact Lens: Science & Clinical Practice, 2020
- One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near additionScientific Reports, 2019
- New Approach for the Calculation of the Intraocular Lens Power Based on the Fictitious Corneal Refractive Index EstimationJournal of Ophthalmology, 2019
- Implantation of a diffractive–refractive trifocal intraocular lens with centralized diffractive rings: Two-year resultsJournal of Cataract & Refractive Surgery, 2019
- Standard Clinical Outcomes With a New Low Addition Trifocal Intraocular LensJournal of Refractive Surgery, 2019
- Fast Measure of Visual Acuity and Contrast Sensitivity Defocus Curves with an iPad ApplicationThe Open Ophthalmology Journal, 2019
- Biometric Factors Associated with the Visual Performance of a High Addition Multifocal Intraocular LensCurrent Eye Research, 2018
- Visual outcomes after progressive apodized diffractive intraocular lens implantationEuropean Journal of Ophthalmology, 2017
- Pursuing perfection in intraocular lens calculations: I. Logical approach for classifying IOL calculation formulasJournal of Cataract & Refractive Surgery, 2017
- Design and qualification of a diffractive trifocal optical profile for intraocular lensesJournal of Cataract & Refractive Surgery, 2011