Noemí Burguera
Research Subjects
Noemí Burguera has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Joaquín Fernández
Qvision, Department of Ophthalmology of VITHAS Almería Hospital, Almería, Spain
10 shared publications - Manuel Rodríguez-Vallejo
Qvision, Department of Ophthalmology of VITHAS Almería Hospital, Almería, Spain
9 shared publications - Carlos Rocha-De-Lossada
Hospital Regional Universitario de Malaga, Malaga, Spain
4 shared publications - Neus Burguera-Giménez
Anterior Segment and Cornea and External Eye Diseases Unit, Fundación de Oftalmología Médica (FOM), Valencia, Spain
4 shared publications - Maria Amparo Díez-Ajenjo
University of Valencia
3 shared publications - Celeste Briceno-Lopez
Universitat de València
2 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Springer Nature in Ophthalmology and Therapy
- p. 1-14
Visual and Patient-Reported Outcomes Following Supplemental Intraocular Lens Implantation for Pseudophakic Refractive Error in Eyes with Complex Ocular Comorbidities
- 10 November 2026
- Published by Springer Nature in Ophthalmology and Therapy
- p. 1-14
Open AccessVisual and Patient-Reported Outcomes Following Supplemental Intraocular Lens Implantation for Pseudophakic Refractive Error in Eyes with Complex Ocular Comorbidities
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Uncorrected Visual Acuity and Visual Function Difficulties After Implantation of Simultaneous Vision Intraocular Lenses
Purpose: To evaluate the association between binocular uncorrected visual acuity (UVA) at different distances and patient-reported difficulty with individual VF-14 activities after implantation of simultaneous vision intraocular lenses (SVIOLs). Setting: (“Masked by journal requirement”) Design: Retrospective observational Methods: Twelve-month data from 276 subjects implanted with either a Full-DOFi Smooth or a Partial-DOFi Extended IOL were included in the analysis. Visual acuities were obtained for far (UDVA, 4 m), intermediate (UIVA, 66 cm), and near (UNVA, 40 cm) distances, along with responses to a validated Spanish version of the VF-14 administered without spectacles. VF-14 responses were dichotomized (little/no vs other), and logistic regression analyses were performed to examine their associations with UDVA, UIVA, and UNVA. Statistical cut-off values were explored using the Youden index. Results: UDVA was significantly associated with “traffic signs” and “night driving” (p < 0.05), whereas “watching TV” showed p = 0.06. UNVA was significantly associated with “knitting” (p < 0.05), whereas “large print” showed p = 0.06, and UIVA was associated with “newspapers” (p = 0.02). “Small print” and “knitting” were associated with both UIVA and UNVA, whereas “filling out forms” was associated only with UNVA (p < 0.05). Visual acuities were not associated with the remaining VF-14 items. Exploratory cut-off values maximizing the Youden index were generally 0.1 logMAR, except for “large print” (0.3 logMAR) and “traffic signs” (0.2 logMAR). Conclusions: Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Uncorrected Visual Acuity and Visual Function Difficulties After Implantation of Simultaneous Vision Intraocular Lenses
Purpose: To evaluate the association between binocular uncorrected visual acuity (UVA) at different distances and patient-reported difficulty with individual VF-14 activities after implantation of simultaneous vision intraocular lenses (SVIOLs). Setting: (“Masked by journal requirement”) Design: Retrospective observational Methods: Twelve-month data from 276 subjects implanted with either a Full-DOFi Smooth or a Partial-DOFi Extended IOL were included in the analysis. Visual acuities were obtained for far (UDVA, 4 m), intermediate (UIVA, 66 cm), and near (UNVA, 40 cm) distances, along with responses to a validated Spanish version of the VF-14 administered without spectacles. VF-14 responses were dichotomized (little/no vs other), and logistic regression analyses were performed to examine their associations with UDVA, UIVA, and UNVA. Statistical cut-off values were explored using the Youden index. Results: UDVA was significantly associated with “traffic signs” and “night driving” (p < 0.05), whereas “watching TV” showed p = 0.06. UNVA was significantly associated with “knitting” (p < 0.05), whereas “large print” showed p = 0.06, and UIVA was associated with “newspapers” (p = 0.02). “Small print” and “knitting” were associated with both UIVA and UNVA, whereas “filling out forms” was associated only with UNVA (p < 0.05). Visual acuities were not associated with the remaining VF-14 items. Exploratory cut-off values maximizing the Youden index were generally 0.1 logMAR, except for “large print” (0.3 logMAR) and “traffic signs” (0.2 logMAR). Conclusions: Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 955-962
One-year outcomes after implantation of an EDOF intraocular lens in patients with cataract
Purpose: To evaluate the clinical outcomes of a new extended depth of focus (EDOF) intraocular lens (IOL) in patients with cataracts. Setting: Qvision, Department of Ophthalmology, VITHAS Almería Hospital, Almería, Spain. Design: Retrospective observational. Methods: Data were retrospectively reviewed for a cohort of 51 consecutively operated patients with cataract implanted with the ELON IOL and followed over a 12-month period. The variables collected for analysis included visual acuities (VAs) at various distances (far, intermediate, and near), light distortion index (LDI), defocus curves, and prediction error. In addition, patient-reported outcomes were gathered to assess spectacle dependence, satisfaction with vision, positive dysphotopsia, difficulties in daily activities, and patients' willingness to undergo the same IOL procedure again. Results: Monocular data for efficacy were available for 36 patients at the 3-month follow-up and 23 patients at the 12-month follow-up. Median monocular distance-corrected VAs were 0 logMAR, 0.1 logMAR, and 0.3 logMAR at 4 m, 66 cm, and 40 cm, respectively, at 3 months and 12 months. Correlations between VAs and pupil diameter were found but only at near for binocular uncorrected (ρ = 0.38, P = .02) and monocular distance corrected (ρ = 0.31, P = .07). The median LDI reduced up to 9% at 12 months. No significant differences were found between follow-up visits for VAs and LDI ( P > .05); however, satisfaction, positive dysphotopsia, and willingness to undergo the same IOL procedure significantly improved from 3 to 12 months ( P < .05). Conclusions: The ELON IOL extended the depth of field from far to intermediate distances, with some patients with smaller pupil diameters also achieving near vision restoration.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 955-962
One-year outcomes after implantation of an EDOF intraocular lens in patients with cataract
Purpose: To evaluate the clinical outcomes of a new extended depth of focus (EDOF) intraocular lens (IOL) in patients with cataracts. Setting: Qvision, Department of Ophthalmology, VITHAS Almería Hospital, Almería, Spain. Design: Retrospective observational. Methods: Data were retrospectively reviewed for a cohort of 51 consecutively operated patients with cataract implanted with the ELON IOL and followed over a 12-month period. The variables collected for analysis included visual acuities (VAs) at various distances (far, intermediate, and near), light distortion index (LDI), defocus curves, and prediction error. In addition, patient-reported outcomes were gathered to assess spectacle dependence, satisfaction with vision, positive dysphotopsia, difficulties in daily activities, and patients' willingness to undergo the same IOL procedure again. Results: Monocular data for efficacy were available for 36 patients at the 3-month follow-up and 23 patients at the 12-month follow-up. Median monocular distance-corrected VAs were 0 logMAR, 0.1 logMAR, and 0.3 logMAR at 4 m, 66 cm, and 40 cm, respectively, at 3 months and 12 months. Correlations between VAs and pupil diameter were found but only at near for binocular uncorrected (ρ = 0.38, P = .02) and monocular distance corrected (ρ = 0.31, P = .07). The median LDI reduced up to 9% at 12 months. No significant differences were found between follow-up visits for VAs and LDI ( P > .05); however, satisfaction, positive dysphotopsia, and willingness to undergo the same IOL procedure significantly improved from 3 to 12 months ( P < .05). Conclusions: The ELON IOL extended the depth of field from far to intermediate distances, with some patients with smaller pupil diameters also achieving near vision restoration.
- Open Access
- 24 January 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (3) , 471-487
Replacing Theories with Evidence Around the Axes of the Eye in Intraocular Lens Selection: A Review for the Clinician
The prevailing narrative in scientific literature has long overemphasized the role of ocular axes in intraocular lens (IOL) implantation, perpetuating misconceptions that have led to unnecessary exclusions of patients. Historical assumptions, coupled with inconsistent terminology and statistical inaccuracies, have muddled clinical decision-making. This review delves into these misconceptions, offering a critical reassessment of their relevance. Drawing from a non-systematic search across PubMed, the IOLEvidence App Database, and additional sources through snowballing, the review includes diverse studies exploring the relationship between ocular axes (angles, chords, kappa, alpha, lens, …) and IOL implantation. The findings reveal widespread confusion in terminology, particularly the interchangeable use of terms like ‘angles’ and ‘chords’, and highlight device-specific variability in parameters such as Chord-mu, Chord-alpha, and Chord-lens. Despite these inconsistencies, no robust evidence supports using these measures as grounds for excluding patients from IOL procedures. Interestingly, postoperative IOL centration (Chord-iol) emerged as a more critical factor for visual outcomes than preoperative ocular axes. The evidence suggests that values for Chord-mu, Chord-alpha, and Chord-lens should prompt further evaluation of atypical cases but are not reliable exclusion criteria. Moreover, a shift in focus toward aligning the IOL slightly temporal to the vertex normal appears to optimize visual acuity and minimize photic phenomena, challenging the established paradigm of knowledge about IOL centration.
- 24 January 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (3) , 471-487
Open AccessReplacing Theories with Evidence Around the Axes of the Eye in Intraocular Lens Selection: A Review for the Clinician
The prevailing narrative in scientific literature has long overemphasized the role of ocular axes in intraocular lens (IOL) implantation, perpetuating misconceptions that have led to unnecessary exclusions of patients. Historical assumptions, coupled with inconsistent terminology and statistical inaccuracies, have muddled clinical decision-making. This review delves into these misconceptions, offering a critical reassessment of their relevance. Drawing from a non-systematic search across PubMed, the IOLEvidence App Database, and additional sources through snowballing, the review includes diverse studies exploring the relationship between ocular axes (angles, chords, kappa, alpha, lens, …) and IOL implantation. The findings reveal widespread confusion in terminology, particularly the interchangeable use of terms like ‘angles’ and ‘chords’, and highlight device-specific variability in parameters such as Chord-mu, Chord-alpha, and Chord-lens. Despite these inconsistencies, no robust evidence supports using these measures as grounds for excluding patients from IOL procedures. Interestingly, postoperative IOL centration (Chord-iol) emerged as a more critical factor for visual outcomes than preoperative ocular axes. The evidence suggests that values for Chord-mu, Chord-alpha, and Chord-lens should prompt further evaluation of atypical cases but are not reliable exclusion criteria. Moreover, a shift in focus toward aligning the IOL slightly temporal to the vertex normal appears to optimize visual acuity and minimize photic phenomena, challenging the established paradigm of knowledge about IOL centration.
- Open Access
- 14 October 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (20) , 2280
Relationship between Choroidal Thickness and Anterior Scleral Thickness in Patients with Keratoconus
Purpose: To evaluate the relationship between choroidal thickness (CT) and anterior scleral thickness (AST) in patients with subclinical keratoconus (SKC) and established keratoconus (KC). Methods: This single-center prospective case-control study included 97 eyes of 97 patients: 44 KC eyes, 14 SKC eyes, and 39 age- and axial length (AL)-matched healthy eyes. Using swept-source optical coherence tomography, the AST was manually measured in four directions and the CT was obtained automatically from the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Principal component analysis (PCA) was used to linearly reduce the dimensionality of nine CT inputs to one significant component, CT1. A multivariate model was created to evaluate the association between CT1, AST, and several ocular parameters in SKC and KC patients. Partial correlation was then performed to adjust the confounding factors and to examine the effect of AST on CT1. Results: The PCA showed that CT1 accounts for 86.54% of the total variance in the nine original CTs of the ETDRS grid. The CT1 model was associated with age, AL, and AST in the superior meridian in SKC eyes, whereas in KC eyes, it was correlated with gender, age, AL, and AST in the inferior meridian (p < 0.001). The partial correlation between CT1 and AST in the superior zone was found to be significant, positive, and strong in SKC eyes (r = 0.79, p = 0.019), whereas a significant, positive, and moderate correlation between CT1 and AST at the inferior zone (r = 0.41, p = 0.017) was observed in KC eyes. Conclusions: Choroidal tissue was significantly correlated with the anterior sclera across the vertical meridian. This relationship was observed over the superior sclera in SKC eyes, whereas in established KC, it was over the inferior sclera. These results reveal new insights regarding the interactions between the anterior and posterior structures of the KC eyes and confirm the enigma of the pathophysiology of KC.
- 14 October 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (20) , 2280
Open AccessRelationship between Choroidal Thickness and Anterior Scleral Thickness in Patients with Keratoconus
Purpose: To evaluate the relationship between choroidal thickness (CT) and anterior scleral thickness (AST) in patients with subclinical keratoconus (SKC) and established keratoconus (KC). Methods: This single-center prospective case-control study included 97 eyes of 97 patients: 44 KC eyes, 14 SKC eyes, and 39 age- and axial length (AL)-matched healthy eyes. Using swept-source optical coherence tomography, the AST was manually measured in four directions and the CT was obtained automatically from the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Principal component analysis (PCA) was used to linearly reduce the dimensionality of nine CT inputs to one significant component, CT1. A multivariate model was created to evaluate the association between CT1, AST, and several ocular parameters in SKC and KC patients. Partial correlation was then performed to adjust the confounding factors and to examine the effect of AST on CT1. Results: The PCA showed that CT1 accounts for 86.54% of the total variance in the nine original CTs of the ETDRS grid. The CT1 model was associated with age, AL, and AST in the superior meridian in SKC eyes, whereas in KC eyes, it was correlated with gender, age, AL, and AST in the inferior meridian (p < 0.001). The partial correlation between CT1 and AST in the superior zone was found to be significant, positive, and strong in SKC eyes (r = 0.79, p = 0.019), whereas a significant, positive, and moderate correlation between CT1 and AST at the inferior zone (r = 0.41, p = 0.017) was observed in KC eyes. Conclusions: Choroidal tissue was significantly correlated with the anterior sclera across the vertical meridian. This relationship was observed over the superior sclera in SKC eyes, whereas in established KC, it was over the inferior sclera. These results reveal new insights regarding the interactions between the anterior and posterior structures of the KC eyes and confirm the enigma of the pathophysiology of KC.
- Open Access
- 19 December 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (2) , 509-527
Subfoveal and Parafoveal Choroidal Thickening in Patients with Keratoconus Using the ETDRS Grid on Swept-Source OCT
Introduction There is growing evidence that confirms morphological changes in the posterior structures in patients with keratoconus (KC); however, isolated alterations could have been missed. This study assesses choroidal thickness (CT) in the fovea and beyond in KC eyes. Methods This prospective case–control and non-randomized study enrolled 107 eyes, 62 eyes of 62 patients with KC, and 45 age-matched eyes of 45 control subjects with axial length in the range of 22–26 mm. Swept-source optical coherence tomography (SS-OCT) was performed to manually measure the subfoveal choroidal thickness (SCT) using a single-line scan. CT was obtained automatically from the Early Treatment Diabetic Retinopathy Study (ETDRS) grid using the 12-lines radial scan pattern. A two-way repeated-measures analysis of variance (ANOVA) was conducted to evaluate CT variations among macular eccentricity, parafoveal area, and the interaction between both factors. CT was compared in all parafoveal areas between groups and subgroups of KC. Results SCT was significantly thicker in KC eyes (357 ± 57 µm) than in healthy eyes (325 ± 63 µm) (p < 0.001). Significant choroidal thickening was observed in the central ring and outer and inner rings of the temporal, superior, and inferior parafoveal macular areas (p < 0.001), except in the outer ring of the nasal macular zone (p > 0.05) of KC compared to healthy eyes. The CT significantly decreased from the center to the outer ring regardless of the presence of KC (p < 0.001). The choroid in the nasal macular zone was significantly thinner than that in the temporal, superior, and inferior parafoveal areas (p < 0.001). Conclusions The choroidal structure increased its thickness not only in the subfoveal area, but also in eight parafoveal areas of the ETDRS grid encompassing a wider area of macular examination. These findings demonstrate and corroborate that keratoconus is not a purely corneal disease. Furthermore, it confirms the role that the choroidal structure has in the pathophysiology of keratoconus.
- 19 December 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (2) , 509-527
Open AccessSubfoveal and Parafoveal Choroidal Thickening in Patients with Keratoconus Using the ETDRS Grid on Swept-Source OCT
Introduction There is growing evidence that confirms morphological changes in the posterior structures in patients with keratoconus (KC); however, isolated alterations could have been missed. This study assesses choroidal thickness (CT) in the fovea and beyond in KC eyes. Methods This prospective case–control and non-randomized study enrolled 107 eyes, 62 eyes of 62 patients with KC, and 45 age-matched eyes of 45 control subjects with axial length in the range of 22–26 mm. Swept-source optical coherence tomography (SS-OCT) was performed to manually measure the subfoveal choroidal thickness (SCT) using a single-line scan. CT was obtained automatically from the Early Treatment Diabetic Retinopathy Study (ETDRS) grid using the 12-lines radial scan pattern. A two-way repeated-measures analysis of variance (ANOVA) was conducted to evaluate CT variations among macular eccentricity, parafoveal area, and the interaction between both factors. CT was compared in all parafoveal areas between groups and subgroups of KC. Results SCT was significantly thicker in KC eyes (357 ± 57 µm) than in healthy eyes (325 ± 63 µm) (p < 0.001). Significant choroidal thickening was observed in the central ring and outer and inner rings of the temporal, superior, and inferior parafoveal macular areas (p < 0.001), except in the outer ring of the nasal macular zone (p > 0.05) of KC compared to healthy eyes. The CT significantly decreased from the center to the outer ring regardless of the presence of KC (p < 0.001). The choroid in the nasal macular zone was significantly thinner than that in the temporal, superior, and inferior parafoveal areas (p < 0.001). Conclusions The choroidal structure increased its thickness not only in the subfoveal area, but also in eight parafoveal areas of the ETDRS grid encompassing a wider area of macular examination. These findings demonstrate and corroborate that keratoconus is not a purely corneal disease. Furthermore, it confirms the role that the choroidal structure has in the pathophysiology of keratoconus.
- Open Access
Anterior Scleral Thickness Profile in Keratoconus
Purpose: Considering that peripheral corneal thinning occurs in keratoconus (KC), the anterior scleral thickness (AST) profile was measured to compare thickness variations in healthy and KC eyes across several meridians. Methods: This cross-sectional case–control study comprised 111 eyes of 111 patients: 61 KC eyes and 50 age- and axial-length-matched healthy eyes. The AST was explored at three scleral eccentricities (1, 2, and 3 mm from the scleral spur) across four scleral zones (nasal, temporal, superior, and inferior) by using swept-source optical coherence tomography. The AST variations among eccentricities and scleral regions within and between groups were investigated. Results: The AST significantly varied with scleral eccentricity in healthy eyes over the temporal meridian (p = 0.009), whereas in KC eyes, this variation was observed over the nasal (p = 0.001), temporal (p = 0.029) and inferior (p = 0.006) meridians. The thinnest point in both groups was 2 mm posterior to the scleral spur (p < 0.001). The sclera was thickest over the inferior region (control 581 ± 52 μm, KC 577 ± 67 μm) and thinnest over the superior region (control 448 ± 48 μm, KC 468 ± 58 μm) in both populations (p < 0.001 for all eccentricities). The AST profiles were not significantly different between groups (p > 0.05). The inferior–superior thickness asymmetry was statistically different 2 mm posterior to the scleral spur between groups (p = 0.009), specifically with subclinical KC (p = 0.03). There is a trend where the asymmetry increases, although not significantly, with the KC degree (p > 0.05). Conclusions: KC eyes presented significant thickness variations among eccentricities over the paracentral sclera. Although AST profiles did not differ between groups, the inferior–superior asymmetry differences demonstrated scleral changes over the vertical meridian in KC that need further investigation.
Open AccessAnterior Scleral Thickness Profile in Keratoconus
Purpose: Considering that peripheral corneal thinning occurs in keratoconus (KC), the anterior scleral thickness (AST) profile was measured to compare thickness variations in healthy and KC eyes across several meridians. Methods: This cross-sectional case–control study comprised 111 eyes of 111 patients: 61 KC eyes and 50 age- and axial-length-matched healthy eyes. The AST was explored at three scleral eccentricities (1, 2, and 3 mm from the scleral spur) across four scleral zones (nasal, temporal, superior, and inferior) by using swept-source optical coherence tomography. The AST variations among eccentricities and scleral regions within and between groups were investigated. Results: The AST significantly varied with scleral eccentricity in healthy eyes over the temporal meridian (p = 0.009), whereas in KC eyes, this variation was observed over the nasal (p = 0.001), temporal (p = 0.029) and inferior (p = 0.006) meridians. The thinnest point in both groups was 2 mm posterior to the scleral spur (p < 0.001). The sclera was thickest over the inferior region (control 581 ± 52 μm, KC 577 ± 67 μm) and thinnest over the superior region (control 448 ± 48 μm, KC 468 ± 58 μm) in both populations (p < 0.001 for all eccentricities). The AST profiles were not significantly different between groups (p > 0.05). The inferior–superior thickness asymmetry was statistically different 2 mm posterior to the scleral spur between groups (p = 0.009), specifically with subclinical KC (p = 0.03). There is a trend where the asymmetry increases, although not significantly, with the KC degree (p > 0.05). Conclusions: KC eyes presented significant thickness variations among eccentricities over the paracentral sclera. Although AST profiles did not differ between groups, the inferior–superior asymmetry differences demonstrated scleral changes over the vertical meridian in KC that need further investigation.
- 1 October 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (10) , 1018-1024
One-year follow-up of a multifocal intraocular lens with optimized elevated phase shift
Purpose: To evaluate the standard outcomes of a multifocal intraocular lens (MIOL) with optimized elevated phase shift (EPS). Setting: (“Masked by journal requirement”) Design: Retrospective observational. Methods: 41 patients, consecutively operated on cataracts or refractive lens exchange with the implantation of the Liberty 640PM (EPS 2.0) and followed during 12-months, were included in the analysis. Retrieved variables were visual acuities at far, intermediate and near distances, defocus curves (VADC), and prediction error of four formulas optimized for IOL Master 500 and Pentacam AXL Wave. Patient reported outcomes were also obtained for assessing spectacle independence, satisfaction, bothersome to dysphotopsia, difficulties in daily life tasks and decision to be operated with the same MIOL. Results: Median monocular efficacy with best distance correction was 0, 0.1 and 0.1 logMAR at far, intermediate and near distances, respectively, with patients achieving binocularly a median of 0 logMAR at the three distances. VADC showed a depth of field of 3 D above 0.2 logMAR with a median increase of 0.07 logMAR from -1.5 D to -2.5 D. Complete spectacle independence was achieved at far distance whereas 97.6% and 85.4% was achieved at intermediate and near distances, respectively. 7.3% of patients were bothered by dysphotopsia and 92.6% of patients were likely to be operated again. Conclusions: EPS 2.0 restored patient’s vision in the full range of field with a nearly monotone decrease of visual performance from far to near, achieving high rates of spectacle independence at all distances and with low positive dysphotopsia rates ( ClinicalTrials.gov Identifier: NCT05735990).
- 1 October 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (10) , 1018-1024
One-year follow-up of a multifocal intraocular lens with optimized elevated phase shift
Purpose: To evaluate the standard outcomes of a multifocal intraocular lens (MIOL) with optimized elevated phase shift (EPS). Setting: (“Masked by journal requirement”) Design: Retrospective observational. Methods: 41 patients, consecutively operated on cataracts or refractive lens exchange with the implantation of the Liberty 640PM (EPS 2.0) and followed during 12-months, were included in the analysis. Retrieved variables were visual acuities at far, intermediate and near distances, defocus curves (VADC), and prediction error of four formulas optimized for IOL Master 500 and Pentacam AXL Wave. Patient reported outcomes were also obtained for assessing spectacle independence, satisfaction, bothersome to dysphotopsia, difficulties in daily life tasks and decision to be operated with the same MIOL. Results: Median monocular efficacy with best distance correction was 0, 0.1 and 0.1 logMAR at far, intermediate and near distances, respectively, with patients achieving binocularly a median of 0 logMAR at the three distances. VADC showed a depth of field of 3 D above 0.2 logMAR with a median increase of 0.07 logMAR from -1.5 D to -2.5 D. Complete spectacle independence was achieved at far distance whereas 97.6% and 85.4% was achieved at intermediate and near distances, respectively. 7.3% of patients were bothered by dysphotopsia and 92.6% of patients were likely to be operated again. Conclusions: EPS 2.0 restored patient’s vision in the full range of field with a nearly monotone decrease of visual performance from far to near, achieving high rates of spectacle independence at all distances and with low positive dysphotopsia rates ( ClinicalTrials.gov Identifier: NCT05735990).
- Open Access
Agreement between Two Devices for Measuring Pupil Diameter in Patients Implanted with Multifocal Intraocular Lenses
The purpose of this study was to evaluate the agreement between three methods for measuring pupil size in patients implanted with multifocal intraocular lenses (MIOLs): Keratograph 5M (K5M), Pentacam AXL Wave (PW), and a simple hand ruler. Sixty-nine subjects implanted with MIOLs and measured at the three-month follow-up visit were included in this retrospective analysis. K5M and PW were used to measure the photopic (PP) and mesopic (MP) pupil sizes, and a hand ruler was used to measure the pupil under environmental light conditions (135 lux). The Bland–Altman method with its limits (LoAs) was used to assess the agreement. The median PP was 2.8, 2.95, and 3 mm for K5M, PW, and the ruler, respectively (p < 0.05). Differences in PP were statistically significant for all paired comparisons (p < 0.0005) except between PW and the ruler (p = 0.44). The LoAs for the difference in PP between K5M and PW was 0.63 mm. The mean difference for MP between K5M and PW was 0.04 mm (p = 0.34) with LoAs of 0.72 mm. MP measured with K5M and PW could be considered interchangeable, although a correction of −0.3 mm (IC95%: −0.23 to −0.39) should be applied to PP measured with PW to attain the K5M mean.
Open AccessAgreement between Two Devices for Measuring Pupil Diameter in Patients Implanted with Multifocal Intraocular Lenses
The purpose of this study was to evaluate the agreement between three methods for measuring pupil size in patients implanted with multifocal intraocular lenses (MIOLs): Keratograph 5M (K5M), Pentacam AXL Wave (PW), and a simple hand ruler. Sixty-nine subjects implanted with MIOLs and measured at the three-month follow-up visit were included in this retrospective analysis. K5M and PW were used to measure the photopic (PP) and mesopic (MP) pupil sizes, and a hand ruler was used to measure the pupil under environmental light conditions (135 lux). The Bland–Altman method with its limits (LoAs) was used to assess the agreement. The median PP was 2.8, 2.95, and 3 mm for K5M, PW, and the ruler, respectively (p < 0.05). Differences in PP were statistically significant for all paired comparisons (p < 0.0005) except between PW and the ruler (p = 0.44). The LoAs for the difference in PP between K5M and PW was 0.63 mm. The mean difference for MP between K5M and PW was 0.04 mm (p = 0.34) with LoAs of 0.72 mm. MP measured with K5M and PW could be considered interchangeable, although a correction of −0.3 mm (IC95%: −0.23 to −0.39) should be applied to PP measured with PW to attain the K5M mean.
- Open Access
Effectiveness of SMILE Combined with Micro-Monovision in Presbyopic Patients: A Pilot Study
Binocular summation along all defocus range after a micro-monovision procedure has scarcely been studied. The aim of this pilot study was to evaluate the efficacy of SMILE combined with different levels of micro-monovision in presbyopic patients and to assess the binocular summation effect on contrast sensitivity defocus curves (CSDC) at the 6-month follow-up. Efficacy was assessed on the basis of visual acuity (VA) and stereopsis at far, intermediate, and near distances. Patient-reported outcomes (PROs) and binocular CSDC were also evaluated. Six patients completed the study with a programmed median anisometropia of 0.81 Diopter. The median binocular uncorrected VA was better than 0 logMAR at the three evaluated distances, and stereopsis was not impaired in any patient, achieving a median of ≤119 arcsec at any distance. CSDC increased binocularly after surgery, significantly in the range of −2 to −3 D (p < 0.05). No clinically relevant changes were observed in PROs compared with the preoperative period, and all patients achieved spectacle independence at intermediate/near distance and were likely or very likely to undergo the same surgery. In conclusion, micro-monovision with SMILE could be an effective procedure, with results that might be comparable to other laser correction techniques specifically designed for presbyopia correction.
Open AccessEffectiveness of SMILE Combined with Micro-Monovision in Presbyopic Patients: A Pilot Study
Binocular summation along all defocus range after a micro-monovision procedure has scarcely been studied. The aim of this pilot study was to evaluate the efficacy of SMILE combined with different levels of micro-monovision in presbyopic patients and to assess the binocular summation effect on contrast sensitivity defocus curves (CSDC) at the 6-month follow-up. Efficacy was assessed on the basis of visual acuity (VA) and stereopsis at far, intermediate, and near distances. Patient-reported outcomes (PROs) and binocular CSDC were also evaluated. Six patients completed the study with a programmed median anisometropia of 0.81 Diopter. The median binocular uncorrected VA was better than 0 logMAR at the three evaluated distances, and stereopsis was not impaired in any patient, achieving a median of ≤119 arcsec at any distance. CSDC increased binocularly after surgery, significantly in the range of −2 to −3 D (p < 0.05). No clinically relevant changes were observed in PROs compared with the preoperative period, and all patients achieved spectacle independence at intermediate/near distance and were likely or very likely to undergo the same surgery. In conclusion, micro-monovision with SMILE could be an effective procedure, with results that might be comparable to other laser correction techniques specifically designed for presbyopia correction.