Utility of FLAER and CD157 in a five‐color single‐tube high sensitivity assay, for diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH)—A standalone flow cytometry laboratory experience
- 15 October 2020
- journal article
- research article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (2) , 259-265
Abstract
Background FLAER-based flow cytometry assay is considered the gold standard for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). CD157 is a recently reported marker for GPI-anchored protein found both on neutrophils and monocytes. This study highlights the robustness of FLAER and CD157 combination to identify PNH clones in a high sensitivity assay. Though rare, the data shown highlight the presence of CD157 negativity in few cases re-emphasizing the importance of FLAER for PNH diagnosis. Methods A single 5-color tube—FLAER Alexa488/ CD157PE/ CD15PECy5/ CD64PE-Cy7 & CD45APCH7—was used for a high sensitivity PNH assay. Results Of 364 cases, 59(16.2%) cases had PNH clone in both granulocytes and monocytes. PNH clone sizes ranged from 0.02% to 96.6% in granulocytes and 0.07% to 96.3% in monocytes based on their FLAER-negative, CD157-negative phenotype. Twenty-two of the 59 PNH cases (37.3%) had WBC clone size of <1%. In addition, there were 10 cases which showed absence of CD 157 expression on both granulocytes and monocytes but on FLAER staining showed normal staining patterns. Three of these ten cases also showed a PNH clone based on absence of FLAER expression on both granulocytes and monocytes. Conclusion FLAER and CD157 is a robust combination for diagnosis of clinical and subclinical PNH. Absence of CD157 expression in normal WBCs, though rare, should be kept in mind and re-emphasizes the importance of FLAER for the high sensitivity PNH assay.Keywords
This publication has 19 references indexed in Scilit:
- Diagnostic screening of paroxysmal nocturnal hemoglobinuria: Prospective multicentric evaluation of the current medical indicationsCytometry Part B: Clinical Cytometry, 2016
- Performance Characteristics of a Non‐Fluorescent Aerolysin‐Based Paroxysmal Nocturnal Hemoglobinuria (PNH) Assay for Simultaneous Evaluation of PNH Neutrophils and PNH Monocytes by Flow Cytometry, Following Published PNH GuidelinesCytometry Part B: Clinical Cytometry, 2016
- Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemiaAnnals of Hematology, 2014
- Clinical relevance of CD157 for rapid and cost‐effective simultaneous evaluation of PNH granulocytes and monocytes by flow cytometryInternational Journal of Laboratory Hematology, 2014
- Use of CD157 in FLAER-based assays for high-sensitivity PNH granulocyte and PNH monocyte detectionCytometry Part B: Clinical Cytometry, 2013
- Practical guidelines for the high‐sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometryCytometry Part B: Clinical Cytometry, 2012
- Guidelines for the diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria and related disorders by flow cytometryCytometry Part B: Clinical Cytometry, 2010
- Multicenter phase 3 study of the complement inhibitor eculizumab for the treatment of patients with paroxysmal nocturnal hemoglobinuriaBlood, 2008
- A prospective comparison of four techniques for diagnosis of paroxysmal nocturnal hemoglobinuriaInternational Journal of Laboratory Hematology, 2007
- Historical aspects of paroxysmal nocturnal haemoglobinuria: ‘defining the disease’British Journal of Haematology, 2002