Kunal Sehgal
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kunal Sehgal has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Alberto Orfao
Department of Medicine Cancer Research and the Cytometry Service of the University of Salamanca Salamanca Spain
1 shared publication- Aleksandr Mikhailovich Popov
Dmitry Rogachev National Medical Research Center of Pediatric Hematology, Oncology and Immunology, 1 Samory Mashela St., Moscow 117198, Russia
1 shared publication Ambreen Pandrowala
B. J. Wadia Hospital for Children Mumbai India
1 shared publication- Ambreen Pandrowala
Department of Blood and Marrow Transplantation, Bai Jerbai Wadia Hospital for Children, Mumbai, India
1 shared publication Ameet Thanky
Department of Physiotherapy, Bai Jerbai Wadia Hospital for Children, Mumbai, India
1 shared publicationAnanthvikas Jayaram
Clinical Division The Cytometry Society‐India Hyderabad Telangana India
1 shared publication
Latest Publications
- 4 August 2026
- Published by Wiley in Cytometry Part B: Clinical Cytometry
Consensus recommendations for technical standardization of flow cytometric measurable residual disease assessment in B ‐cell acute lymphoblastic leukemia: A report from The Cytometry Society, India
Measurable residual disease (MRD) assessment is a key determinant of risk stratification and treatment modification in B‐cell acute lymphoblastic leukemia (B‐ALL). Multicolour flow cytometry (MFC) is a globally adopted rapid and sensitive MRD technique. However, technical practices remain significantly variable across laboratories, compromising assay sensitivity, reproducibility, and comparability. Currently, systemic recommendations providing guidelines on the technical aspects of MFC‐MRD in B‐ALL are unavailable. The Cytometry Society (TCS)‐India undertook a structured consensus process to standardize technical aspects of MFC‐MRD testing. A two‐round Delphi survey was conducted among laboratory professionals and clinicians across India to capture the prevailing practices and priorities. Consensus recommendations were prepared through survey findings and further refined during an in‐person consensus congress with national and international experts from Australia, Egypt, Spain, and Russia. This document provides comprehensive recommendations across pre‐analytic, analytic, and post‐analytic phases of MFC‐MRD including minimal antibody panel, best practices for sample collection, transport, and processing, Instrument setup, quality control, acquisition targets, gating strategies, approaches for LOD/LLOQ definition, hemodilution assessment, etc. A structured MRD report format with quality caveats is also provided. The recommendations are categorized into “Must,” “Preferred,” and “Acceptable” levels to suit diverse resource settings while promoting harmonization. Implementation of these standards will enhance assay sensitivity, reproducibility, and comparability, thereby strengthening MRD‐guided clinical decision‐making in B‐ALL.
- 4 August 2026
- Published by Wiley in Cytometry Part B: Clinical Cytometry
Consensus recommendations for technical standardization of flow cytometric measurable residual disease assessment in B ‐cell acute lymphoblastic leukemia: A report from The Cytometry Society, India
Measurable residual disease (MRD) assessment is a key determinant of risk stratification and treatment modification in B‐cell acute lymphoblastic leukemia (B‐ALL). Multicolour flow cytometry (MFC) is a globally adopted rapid and sensitive MRD technique. However, technical practices remain significantly variable across laboratories, compromising assay sensitivity, reproducibility, and comparability. Currently, systemic recommendations providing guidelines on the technical aspects of MFC‐MRD in B‐ALL are unavailable. The Cytometry Society (TCS)‐India undertook a structured consensus process to standardize technical aspects of MFC‐MRD testing. A two‐round Delphi survey was conducted among laboratory professionals and clinicians across India to capture the prevailing practices and priorities. Consensus recommendations were prepared through survey findings and further refined during an in‐person consensus congress with national and international experts from Australia, Egypt, Spain, and Russia. This document provides comprehensive recommendations across pre‐analytic, analytic, and post‐analytic phases of MFC‐MRD including minimal antibody panel, best practices for sample collection, transport, and processing, Instrument setup, quality control, acquisition targets, gating strategies, approaches for LOD/LLOQ definition, hemodilution assessment, etc. A structured MRD report format with quality caveats is also provided. The recommendations are categorized into “Must,” “Preferred,” and “Acceptable” levels to suit diverse resource settings while promoting harmonization. Implementation of these standards will enhance assay sensitivity, reproducibility, and comparability, thereby strengthening MRD‐guided clinical decision‐making in B‐ALL.
- Open Access
- 7 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3397
Rapid Detection of Plasmodium vivax by the Hematology Analyzer for Population Screening
In India, where malaria is endemic, the prompt and accurate detection of infections is crucial for disease management and vector control. Our study aimed to evaluate the “iRBC” flag, a novel parameter developed for routine hematology analyzers, for its sensitivity and specificity in detecting Plasmodium vivax (P. vivax) infections. We used residual blood samples from patients with suspected malaria and compared the iRBC flag results with microscopy, which serves as the gold standard. Additionally, we compared the results with rapid immuno-chromatographic tests (RDTs) commonly used in the field. Our study included 575 samples, of which 187 were positive for P. vivax. The iRBC flag demonstrated a high sensitivity of 88.7% and 86.1% on the XN and XN-L hematology analyzers, respectively, and a clinical specificity of 100% on both analyzers. Furthermore, the scattergram derived from each positive dataset exhibited distinct patterns, which facilitated rapid confirmation by laboratory specialists. Notably, the iRBC flag remained effective even in the presence of interfering conditions. Overall, our results indicate that the iRBC flag is a reliable and rapid screening tool for identifying P. vivax in routine blood testing. Our findings have significant implications for malaria detection and control in endemic regions like India.
- 7 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3397
Open AccessRapid Detection of Plasmodium vivax by the Hematology Analyzer for Population Screening
In India, where malaria is endemic, the prompt and accurate detection of infections is crucial for disease management and vector control. Our study aimed to evaluate the “iRBC” flag, a novel parameter developed for routine hematology analyzers, for its sensitivity and specificity in detecting Plasmodium vivax (P. vivax) infections. We used residual blood samples from patients with suspected malaria and compared the iRBC flag results with microscopy, which serves as the gold standard. Additionally, we compared the results with rapid immuno-chromatographic tests (RDTs) commonly used in the field. Our study included 575 samples, of which 187 were positive for P. vivax. The iRBC flag demonstrated a high sensitivity of 88.7% and 86.1% on the XN and XN-L hematology analyzers, respectively, and a clinical specificity of 100% on both analyzers. Furthermore, the scattergram derived from each positive dataset exhibited distinct patterns, which facilitated rapid confirmation by laboratory specialists. Notably, the iRBC flag remained effective even in the presence of interfering conditions. Overall, our results indicate that the iRBC flag is a reliable and rapid screening tool for identifying P. vivax in routine blood testing. Our findings have significant implications for malaria detection and control in endemic regions like India.
- Open Access
- 29 March 2023
- Published by Elsevier in Journal of Allergy and Clinical Immunology: Global
- Vol. 2 (3) , 100105
Changing outcomes of stem cell transplantation in primary immunodeficiencies: Results from a tertiary-care charitable trust hospital in Mumbai
- 29 March 2023
- Published by Elsevier in Journal of Allergy and Clinical Immunology: Global
- Vol. 2 (3) , 100105
Open AccessChanging outcomes of stem cell transplantation in primary immunodeficiencies: Results from a tertiary-care charitable trust hospital in Mumbai
- 15 October 2020
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (2) , 259-265
Utility of FLAER and CD157 in a five‐color single‐tube high sensitivity assay, for diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH)—A standalone flow cytometry laboratory experience
Background FLAER-based flow cytometry assay is considered the gold standard for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). CD157 is a recently reported marker for GPI-anchored protein found both on neutrophils and monocytes. This study highlights the robustness of FLAER and CD157 combination to identify PNH clones in a high sensitivity assay. Though rare, the data shown highlight the presence of CD157 negativity in few cases re-emphasizing the importance of FLAER for PNH diagnosis. Methods A single 5-color tube—FLAER Alexa488/ CD157PE/ CD15PECy5/ CD64PE-Cy7 & CD45APCH7—was used for a high sensitivity PNH assay. Results Of 364 cases, 59(16.2%) cases had PNH clone in both granulocytes and monocytes. PNH clone sizes ranged from 0.02% to 96.6% in granulocytes and 0.07% to 96.3% in monocytes based on their FLAER-negative, CD157-negative phenotype. Twenty-two of the 59 PNH cases (37.3%) had WBC clone size of <1%. In addition, there were 10 cases which showed absence of CD 157 expression on both granulocytes and monocytes but on FLAER staining showed normal staining patterns. Three of these ten cases also showed a PNH clone based on absence of FLAER expression on both granulocytes and monocytes. Conclusion FLAER and CD157 is a robust combination for diagnosis of clinical and subclinical PNH. Absence of CD157 expression in normal WBCs, though rare, should be kept in mind and re-emphasizes the importance of FLAER for the high sensitivity PNH assay.
- 15 October 2020
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (2) , 259-265
Utility of FLAER and CD157 in a five‐color single‐tube high sensitivity assay, for diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH)—A standalone flow cytometry laboratory experience
Background FLAER-based flow cytometry assay is considered the gold standard for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). CD157 is a recently reported marker for GPI-anchored protein found both on neutrophils and monocytes. This study highlights the robustness of FLAER and CD157 combination to identify PNH clones in a high sensitivity assay. Though rare, the data shown highlight the presence of CD157 negativity in few cases re-emphasizing the importance of FLAER for PNH diagnosis. Methods A single 5-color tube—FLAER Alexa488/ CD157PE/ CD15PECy5/ CD64PE-Cy7 & CD45APCH7—was used for a high sensitivity PNH assay. Results Of 364 cases, 59(16.2%) cases had PNH clone in both granulocytes and monocytes. PNH clone sizes ranged from 0.02% to 96.6% in granulocytes and 0.07% to 96.3% in monocytes based on their FLAER-negative, CD157-negative phenotype. Twenty-two of the 59 PNH cases (37.3%) had WBC clone size of <1%. In addition, there were 10 cases which showed absence of CD 157 expression on both granulocytes and monocytes but on FLAER staining showed normal staining patterns. Three of these ten cases also showed a PNH clone based on absence of FLAER expression on both granulocytes and monocytes. Conclusion FLAER and CD157 is a robust combination for diagnosis of clinical and subclinical PNH. Absence of CD157 expression in normal WBCs, though rare, should be kept in mind and re-emphasizes the importance of FLAER for the high sensitivity PNH assay.
- Open Access
- 1 January 2015
- Published by Medknow in Indian Journal of Pathology and Microbiology
- Vol. 58 (3) , 310-315
Sehgal index: A new index and its comparison with other complete blood count-based indices for screening of beta thalassemia trait in a tertiary care hospital
Introduction: Beta thalassemia trait (BTT) must be differentiated from iron deficiency anemia to avoid unnecessary iron therapy and for the prevention of thalassemia major by genetic counseling. In a tertiary care hospital, it is vital that the screening tool is not only sensitive but also specific so as to be cost effective and save time. Aim: The aim of this study was to evaluate the new Sehgal index and compare it to existing complete blood count-based indices for the best combination of sensitivity and specificity to predict BTT. Materials and Methods: Study was done in 2 phases - Phase 1: A retrospective analysis of 1022 consecutive high-performance liquid chromatography (HPLC) cases from July 2008 to June 2011. Phase 2: A prospective analysis of 973 consecutive HPLC cases from July 1, 2011 to June 10, 2013 was done to confirm the results of Phase 1 and the applicability of the new Sehgal index. Results: Prevalence of BTT was 28.8% (294/1022) and 25.39% (247/973) in Phase 1 and Phase 2, respectively. Receiver operating characteristic-area under the curve and Youden index was highest for new Sehgal index, followed by Mentzers index <14. The prospective study shows results similar to those in Phase 1 confirming the superiority of the above two indices. Conclusion: Sehgal index and Mentzers index <14 showed the best combination of sensitivity and specificity in predicting BTT. The best indices or combination can be used as a "validated flag rule" in the analyzer middleware program in a hospital for identifying suspected cases of BTT.
- 1 January 2015
- Published by Medknow in Indian Journal of Pathology and Microbiology
- Vol. 58 (3) , 310-315
Open AccessSehgal index: A new index and its comparison with other complete blood count-based indices for screening of beta thalassemia trait in a tertiary care hospital
Introduction: Beta thalassemia trait (BTT) must be differentiated from iron deficiency anemia to avoid unnecessary iron therapy and for the prevention of thalassemia major by genetic counseling. In a tertiary care hospital, it is vital that the screening tool is not only sensitive but also specific so as to be cost effective and save time. Aim: The aim of this study was to evaluate the new Sehgal index and compare it to existing complete blood count-based indices for the best combination of sensitivity and specificity to predict BTT. Materials and Methods: Study was done in 2 phases - Phase 1: A retrospective analysis of 1022 consecutive high-performance liquid chromatography (HPLC) cases from July 2008 to June 2011. Phase 2: A prospective analysis of 973 consecutive HPLC cases from July 1, 2011 to June 10, 2013 was done to confirm the results of Phase 1 and the applicability of the new Sehgal index. Results: Prevalence of BTT was 28.8% (294/1022) and 25.39% (247/973) in Phase 1 and Phase 2, respectively. Receiver operating characteristic-area under the curve and Youden index was highest for new Sehgal index, followed by Mentzers index <14. The prospective study shows results similar to those in Phase 1 confirming the superiority of the above two indices. Conclusion: Sehgal index and Mentzers index <14 showed the best combination of sensitivity and specificity in predicting BTT. The best indices or combination can be used as a "validated flag rule" in the analyzer middleware program in a hospital for identifying suspected cases of BTT.