Quantitative Evaluation Method for Defect Size of Aluminum Plates Based on Normal Coaxial Dual Receiving Coil ECT Probe
Authors:
Preprint
- 22 April 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Eddy Current Testing (ECT) is a core non-destructive testing technique for conductive materials. The traditional single-coil eddy current testing method largely relies on a stable lift-off value, but in practical testing, lift-off perturbations caused by vibrations of the testing equipment directly affects the quality of the eddy current signal, thereby reducing the accuracy of defect evaluation. In this paper, a quantitative evaluation method for aluminum plate defect size based on a normal coaxial dual-receiving coil ECT probe is proposed. First, an ECT experimental system integrating signal excitation, data acquisition and motion control modules is established, and a self-designed normal coaxial dual-receiving coil ECT probe is adopted to realize the joint acquisition of eddy current signals under different lift-off values. A signal symmetrization preprocessing procedure based on flip interpolation and fourth-order low-pass filtering is also established to eliminate the asymmetric perturbation caused by mechanical vibration and platform fluctuation. Second, a three-dimensional finite element simulation model of eddy current based on the normal coaxial dual-receiving coil probe is established, and the distribution laws of the magnetic field and eddy current field are analyzed to verify the reliability of the probe structure design. Finally, ECT experiments and defect size evaluation studies are conducted on aluminum plates with surface circular hole defects, and a fast calculation model for eddy current signals is established based on the testing data of these defects. A quantitative evaluation method for aluminum plate surface defect size that takes lift-off perturbation into account is further constructed based on the particle swarm optimization (PSO) algorithm. This research finds that the peak-to-peak voltage feature of surface circular hole defect signals shows a monotonic correlation with both defect parameters and lift-off values under a lift-off perturbation range of -0.2 mm to 0.2 mm. In the presence of lift-off perturbation, the traditional single-coil ECT method results in an evaluation error of more than 38%, while the proposed ECT system can quantitatively evaluate the radius and depth of circular hole defects with errors controlled within ±0.5% and 4%, respectively. This work provides reliable technical support for the quantitative testing of surface defects in conductive materials under complex industrial conditions.Keywords
This publication has 13 references indexed in Scilit:
- A dual-stage dimensionless method for simultaneous estimation of electrical conductivity, lift-off, and thickness in Eddy Current TestingMeasurement, 2026
- Machine learning-based phased array ultrasonic testing for graded materials: A comprehensive defect detection and quantification frameworkNDT & E International, 2025
- A Sensor Fusion Strategy to Compensate Lift-Off Noise for Eddy Current TestingIEEE Sensors Journal, 2024
- Real-Time Tunnel-Magnetoresistive-Based Pulsed Eddy Current Testing With Deep LearningIEEE Sensors Journal, 2024
- Eddy current testing of small radius conductive cylinders with the employment of an I-core sensorMeasurement, 2021
- Flexible Floral Eddy Current Probe for Detecting Flaws in Metal PlateIEEE Sensors Journal, 2020
- Quantitative evaluation of crack depths and angles for pulsed eddy current non-destructive testingNDT & E International, 2019
- Advances and Researches on Non Destructive Testing: A ReviewMaterials Today: Proceedings, 2018
- Lift-off effect reduction based on the dynamic trajectories of the received-signal fast Fourier transform in pulsed eddy current testingNDT & E International, 2017
- A Novel Triple-Coil Electromagnetic Sensor for Thickness Measurement Immune to Lift-Off VariationsIEEE Transactions on Instrumentation and Measurement, 2015