Dong Li
Dong Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Junxia Li
Taiyuan University of Technology
2 shared publications Shaoni Jiao
2 shared publicationsShuai Hao
2 shared publicationsHaowen Zheng
1 shared publication- Haowen Zheng1 shared publication
- Jianke Gao
National - Local Joint Engineering Laboratory of Mining Fluid Control
1 shared publication
Latest Publications
- 14 July 2026
- Published by Elsevier in NDT & E International
- Vol. 164
Quantitative evaluation method for defect size of aluminum plates based on normal coaxial dual receiving coil ECT probe
- 14 July 2026
- Published by Elsevier in NDT & E International
- Vol. 164
Quantitative evaluation method for defect size of aluminum plates based on normal coaxial dual receiving coil ECT probe
- 4 July 2026
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 37 (4) , 233-262
Research on Eddy Current Testing of Conveyor Belt Joint Twitch Based on MixUp-CS-CNN
1. Mining depth continues to increase as mineral resources are developed. At the same time, the demands on equipment that transports minerals from underground to designated locations are also growi...
- 4 July 2026
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 37 (4) , 233-262
Research on Eddy Current Testing of Conveyor Belt Joint Twitch Based on MixUp-CS-CNN
1. Mining depth continues to increase as mineral resources are developed. At the same time, the demands on equipment that transports minerals from underground to designated locations are also growi...
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Quantitative Evaluation Method for Defect Size of Aluminum Plates Based on Normal Coaxial Dual Receiving Coil ECT Probe
Eddy Current Testing (ECT) is a core non-destructive testing technique for conductive materials. The traditional single-coil eddy current testing method largely relies on a stable lift-off value, but in practical testing, lift-off perturbations caused by vibrations of the testing equipment directly affects the quality of the eddy current signal, thereby reducing the accuracy of defect evaluation. In this paper, a quantitative evaluation method for aluminum plate defect size based on a normal coaxial dual-receiving coil ECT probe is proposed. First, an ECT experimental system integrating signal excitation, data acquisition and motion control modules is established, and a self-designed normal coaxial dual-receiving coil ECT probe is adopted to realize the joint acquisition of eddy current signals under different lift-off values. A signal symmetrization preprocessing procedure based on flip interpolation and fourth-order low-pass filtering is also established to eliminate the asymmetric perturbation caused by mechanical vibration and platform fluctuation. Second, a three-dimensional finite element simulation model of eddy current based on the normal coaxial dual-receiving coil probe is established, and the distribution laws of the magnetic field and eddy current field are analyzed to verify the reliability of the probe structure design. Finally, ECT experiments and defect size evaluation studies are conducted on aluminum plates with surface circular hole defects, and a fast calculation model for eddy current signals is established based on the testing data of these defects. A quantitative evaluation method for aluminum plate surface defect size that takes lift-off perturbation into account is further constructed based on the particle swarm optimization (PSO) algorithm. This research finds that the peak-to-peak voltage feature of surface circular hole defect signals shows a monotonic correlation with both defect parameters and lift-off values under a lift-off perturbation range of -0.2 mm to 0.2 mm. In the presence of lift-off perturbation, the traditional single-coil ECT method results in an evaluation error of more than 38%, while the proposed ECT system can quantitatively evaluate the radius and depth of circular hole defects with errors controlled within ±0.5% and 4%, respectively. This work provides reliable technical support for the quantitative testing of surface defects in conductive materials under complex industrial conditions.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessQuantitative Evaluation Method for Defect Size of Aluminum Plates Based on Normal Coaxial Dual Receiving Coil ECT Probe
Eddy Current Testing (ECT) is a core non-destructive testing technique for conductive materials. The traditional single-coil eddy current testing method largely relies on a stable lift-off value, but in practical testing, lift-off perturbations caused by vibrations of the testing equipment directly affects the quality of the eddy current signal, thereby reducing the accuracy of defect evaluation. In this paper, a quantitative evaluation method for aluminum plate defect size based on a normal coaxial dual-receiving coil ECT probe is proposed. First, an ECT experimental system integrating signal excitation, data acquisition and motion control modules is established, and a self-designed normal coaxial dual-receiving coil ECT probe is adopted to realize the joint acquisition of eddy current signals under different lift-off values. A signal symmetrization preprocessing procedure based on flip interpolation and fourth-order low-pass filtering is also established to eliminate the asymmetric perturbation caused by mechanical vibration and platform fluctuation. Second, a three-dimensional finite element simulation model of eddy current based on the normal coaxial dual-receiving coil probe is established, and the distribution laws of the magnetic field and eddy current field are analyzed to verify the reliability of the probe structure design. Finally, ECT experiments and defect size evaluation studies are conducted on aluminum plates with surface circular hole defects, and a fast calculation model for eddy current signals is established based on the testing data of these defects. A quantitative evaluation method for aluminum plate surface defect size that takes lift-off perturbation into account is further constructed based on the particle swarm optimization (PSO) algorithm. This research finds that the peak-to-peak voltage feature of surface circular hole defect signals shows a monotonic correlation with both defect parameters and lift-off values under a lift-off perturbation range of -0.2 mm to 0.2 mm. In the presence of lift-off perturbation, the traditional single-coil ECT method results in an evaluation error of more than 38%, while the proposed ECT system can quantitatively evaluate the radius and depth of circular hole defects with errors controlled within ±0.5% and 4%, respectively. This work provides reliable technical support for the quantitative testing of surface defects in conductive materials under complex industrial conditions.