Abstract
Achieving efficient power regulation without communication in wireless power transfer (WPT) systems remains a significant challenge, particularly under varying load and coupling conditions. This article proposes a dual-frequency dual-channel WPT system by introducing a third harmonic resonant channel alongside the fundamental power channel. The third harmonic current serves multiple roles: it enables communication-free synchronization via implicit phase feedback, contributes actively to power transfer, and extends the zero-voltage switching (ZVS) range of the primary-side inverter without increasing the switching frequency. A two-stage synchronous control strategy is developed to regulate power based solely on local measurements, avoiding complex sensing, parameters estimation, or digital modulation-demodulation. To control the overall size of the coupler, a compact coil design is adopted, while maintaining a competitive power density. The proposed system is validated on a 1.7 kW experimental platform. Results confirm the system’s wide ZVS range and its ability to maintain stable control without communication. The system achieves a peak efficiency of 94.39%, and remains above 93.5% when the output power exceeds 50% .
Funding Information
  • National Natural Science Foundation of China (52077183)
  • Chengdu Municipal Science and Technology Program (2024-YF05-00673-SN)
  • Doctoral Innovation Fund Program of Southwest Jiaotong University (CX-2025ZD02)