LMLinghui Meng

Linghui Meng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linghui Meng has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Dual-Frequency Dual-Channel WPT System With Wide Range ZVS and Communication-Free Capability

    by Jingchi Wu, Linghui Meng, Yuhao Deng, Youshong Zhou, Jiangpeng Yang, Shun Wang, Siyang Liu, Zeliang Shu

    Achieving efficient power regulation without communication in wireless power transfer (WPT) systems remains a significant challenge, particularly under varying load and coupling conditions. This article proposes a dual-frequency dual-channel WPT system by introducing a third harmonic resonant channel alongside the fundamental power channel. The third harmonic current serves multiple roles: it enables communication-free synchronization via implicit phase feedback, contributes actively to power transfer, and extends the zero-voltage switching (ZVS) range of the primary-side inverter without increasing the switching frequency. A two-stage synchronous control strategy is developed to regulate power based solely on local measurements, avoiding complex sensing, parameters estimation, or digital modulation-demodulation. To control the overall size of the coupler, a compact coil design is adopted, while maintaining a competitive power density. The proposed system is validated on a 1.7 kW experimental platform. Results confirm the system’s wide ZVS range and its ability to maintain stable control without communication. The system achieves a peak efficiency of 94.39%, and remains above 93.5% when the output power exceeds 50% .


  • The Constant Power Transmission Control for Suppressing DC-Link Voltage Ripple Effect of Single-Phase AC–DC–AC Converter

    by Minyang Zou, Linghui Meng, Jianglin Nie, Jiajin Li, Linzhe Li, Xiao Lv, Cheng Zhang, Xifeng Xie, Zeliang Shu

    The dual active bridge (DAB) converter achieves relatively high efficiency and high power density. Therefore, it is widely used in ac–dc–ac converters to provide electrical isolation between the input and output. However, the single-phase converter inherently exhibits significant low-frequency voltage ripple in the DAB topology. Traditional control strategies focus on reducing voltage ripple and optimizing the capacitor size by transferring fluctuating power through the DAB converter. This method leads to higher magnetic component and switch currents, as well as a larger transformer size. To suppress these effects, this article proposes a constant power transmission (CPT) control for the DAB converter. The proposed CPT control dynamically adjusts the modulation width of each operating cycle by tracking the input–output voltage fluctuations in real-time through the control variables. This ensures constant power transfer in the DAB converter. Compared to traditional methods, the proposed control strategy reduces both the RMS and peak-to-peak values of the inductor current, thereby reducing the size of the converter and improving system efficiency. Simulation and experimental results confirm that the CPT control effectively reduces the peak-to-peak and RMS values of the inductor current by 40.7% and 18.8%, respectively, reduces the transformer size by 21.4%, and increases the efficiency by 1.1%.


  • A Three-Port Five-Channel Converter With High Output Current and Wide Voltage Range

    by Jianglin Nie, Wanxin Luo, Cheng Zhang, Jiangpeng Yang, Linghui Meng, Lan Ma, Zeliang Shu

    This article proposes a three-port converter utilizing five power channels. Four of these channels form an output-parallel multiphase interleaved LLC structure, designed to transfer the energy to high power and current loads. The other channel operates as an equivalent multilevel dual active bridge (DAB) converter, connects to a wide voltage range load and allows for bidirectional energy flow. The four LLC channels efficiently transfer power while significantly enhancing the soft-switching capability of the DAB channel. In addition, the high-voltage side switches operate with half voltage stress, which not only mitigates the challenges associated with soft-switching but also improves the overall reliability of the converter. To further optimize the performance, a modulation method is introduced for the proposed converter, enabling phase-shift control of four LLC channels and reducing the peak current in the DAB converter. Finally, a 3-kW prototype is developed to validate the effectiveness of the proposed converter. One port of the prototype has half of the input voltage stress, enabling it to handle a high input voltage of 750 V, while another port achieves a wide output voltage range of 40–200 V, and the third port delivers a high output current of 40 A.


  • 4-Vector SVPWM for Single-Phase Transformerless UPQC With Two-Leg and Low DC Voltage

    by Shun Wang, Cen Tang, Jianglin Nie, Linghui Meng, Zeliang Shu

    In this letter, we propose a single-phase transformerless unified power quality conditioner (UPQC) with two legs. Owing to the limited quantity of switches, the half-bridge (HB) UPQC consists of a HB dynamic voltage restorer (DVR) and an active power filter (APF). The proposed topology maintains constant switching stress under all operational scenarios by combining an HB DVR with a full-bridge (FB) APF without increasing the number of switches. To address the issue of current compensation and voltage compensation coupling caused by the shared leg, a four-vector space vector pulsewidth modulation (SVPWM) is proposed for decoupling. With the proposed SVPWM for independent control reference calculation, the effects of dc voltage and load current on voltage compensation can be eliminated by the control strategy. Finally, the effectiveness of the topology and modulation strategy are verified by the experimental results.


  • A Three Coordinated Power Channels LLC Converter With Ultrawide Voltage Range

    by Jianglin Nie, Yuhao Deng, Jiangpeng Yang, Linghui Meng, Lan Ma, Zeliang Shu

    To achieve ultrawide output voltage range, this paper proposes a novel isolated LLC resonant converter with three coordinated power channels. The proposed converter features three working conditions and encompasses five operation patterns, allowing for the adjustment of quality factor for a wider gain range. With more power channels, the converter can reduce the stress of the resonant tank and switches to further improve the higher power level and achieve the soft switching. To ensure smooth gain transition and a wider gain range, the turns ratio of the transformer is designed by considering three different conditions. Finally, a 1 kW prototype was built to verify the effectiveness of the proposed topology. The results confirm the eight times output voltage range of the converter and a peak efficiency of 96%.


  • Online Inductance Identification and FPGA-Based Real-Time Digital Control Design for APF

    by Yousong Zhou, Jiangpeng Yang, Linghui Meng, Jiaxuan Yao, Lan Ma, Haiquan Zhao, Zeliang Shu

    The harmonic suppression performance of active power filter (APF) under model predictive current control is obviously reduced, when the parameter exists a mismatch between the actual value in system and the nominal value adopted in the control. To suppress the influence of parameter mismatching, a model predictive control based on parameter identification with forgetting factor recursive least square (FFRLS) method is proposed for APF. The digital processing procedure of the FFRLS-based APF controller is detailed analyzed and designed. The identification error of inductance between identification value and the actual value is less to 6%, and the total harmonic distortion of grid current is significantly improved, especially a lower value of actual inductance. Simulation and experimental results show that the proposed method can not only effectively eliminate the influence of parameter mismatch on the control, but also result in better steady-state performance while retaining fast dynamic response.


  • Control Strategy of Single-Phase UPQC for Suppressing the Influences of Low-Frequency DC-Link Voltage Ripple

    by Linghui Meng, Lan Ma, Weiwei Zhu, Han Yan, Tianxiang Wang, Wenjun Mao, Xiaoqiong He, Zeliang Shu

    The single-phase unified power quality conditioner (UPQC) is widely used to improve the power quality of sensitive end-users. However, the inherent instantaneous power difference between parallel and series converter will generate a significant low-frequency dc-link voltage ripple and degrade the compensation performance of UPQC. The generation mechanism of dc-link voltage ripple and its influences on compensation voltage and current are analyzed in this paper. To suppress the influence, a control strategy is proposed for the single-phase UPQC. For parallel converter, a notch filter is introduced in the outer voltage loop to prevent the ripple from entering the control loop, the specific order harmonic compensation is proposed in the inner current loop to reduce the grid current harmonics. For series converter, the dc-link voltage feedback is adopted to suppress the influence of voltage ripple on the compensation performance. Simulation and experimental results show that the grid current total harmonic distortion (THD) can be reduced effectively with the fixed dc-link capacitance compared with the traditional control strategy. The load voltage THD has also been reduced by more than half by the dc-link voltage feedback control. Moreover, with the smaller dc-link capacitance, single-phase UPQC can maintain better performance under the proposed control strategy.


  • Optimal Input and Output Power Quality Control of Single-Phase AC–DC–DC Converter With Significant DC-Link Voltage Ripple

    by Linghui Meng, Zeliang Shu, Yuan Lei, Han Yan, Zuyong Li, Lan Ma, Xiaodong Yin, Xiaoqiong He

    A single-phase isolated ac-dc-dc converter with low total harmonic distortion (THD) and high power factor (PF) usually suffers from a significant ripple power at double line frequency. The inherent ripple power brings a significant low-frequency voltage ripple on the dc-link capacitor. To reduce the voltage ripple, bulky electrolytic capacitors and hardware low-pass filter are widely adopted. However, the converter becomes bulky because of large capacitor. In order to reduce the dc-link capacitance, optimal control strategies are proposed for ac-dc and dc-dc converter respectively in this paper. Firstly, the notch filter with current disturbance feedforward strategy (NF-CDFS) are proposed to minimize input harmonic current of ac-dc converter. Secondly, the feedback linearization with voltage disturbance feedforward strategy (FLVDFS) is designed to suppress the output voltage ripple of dc-dc converter based on generalized state space averaging model. With the proposed NF-CDFS plus FLVDFS control strategy, low input harmonic current and low output voltage ripple are achieved. In addition, more than about 85% of dc-link capacitance is reduced compared to conventional methods.