The effect of water molecular self-diffusion on quantitative high-resolution MRI polymer gel dosimetry
Authors:
- Y De DeeneYDY De Deene
- R MederRMR Meder
- J M PopeJPJ M Pope
- C BaldockCBC Baldock
- 4 September 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (18) , 3043-3058
Abstract
In polymer gel dosimetry, magnetic resonance imaging (MRI) is used to determine the spin-spin relaxation rate (R2) which in turn can be correlated with absorbed dose to provide a map of the spatial distribution of the absorbed dose in the irradiated dosimeter. High accuracy, precision and reproducibility of these dose maps are essential. Moreover, for dose verification around brachytherapy sources used for intravascular brachytherapy, a high spatial resolution is required (typically 0.01-0.1 mm). To achieve these microscopic resolutions, strong imaging gradients are applied. The Brownian motion of water molecules in the presence of these strong magnetic field gradients causes an attenuation of the MR signal. When using a multiple spin-echo sequence, this may result in a significant deviation in the measured R2. The diffusion-related change in R2 at high resolutions was investigated experimentally and correlated with predictions that were obtained numerically and algebraically. Diffusion weighting is determined by the self-diffusion coefficient D, and imaging parameters, quantified by the b-factor. The b-factor was calculated for a multiple spin-echo sequence for different gradient strengths and gradient pulse durations. The variations in R2 that were observed when changing the matrix size and slice thickness are explained. It is shown that a linear correlation between the matrix size and the variation in R2 is based on the diffusion weighting caused by the read-out gradients and slice selective gradients. In conclusion, the essence of taking into account molecular self-diffusion to quantify variations in the measured dose-R2 response when using high-resolution MRI in polymer gel dosimetry is emphasized.Keywords
This publication has 34 references indexed in Scilit:
- High resolution polymer gel dosimetry by parameter selective MR‐microimaging on a whole body scanner at 3 TMedical Physics, 2001
- Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element methodAustralasian Physics & Engineering Sciences in Medicine, 2001
- Artefacts in multi-echoT2imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currentsPhysics in Medicine & Biology, 2000
- Assessment of the relative dose distribution around an line source using a liquid ionization chamberMedical Physics, 1999
- Review of endovascular brachytherapy physics for prevention of restenosisCardiovascular Radiation Medicine, 1999
- Experimental determination of dosimetry functions of Ir‐192 sourcesMedical Physics, 1998
- Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetryPhysics in Medicine & Biology, 1998
- Molecular Diffusion in NMR MicroscopyJournal of Magnetic Resonance, Series B, 1994
- Diffusive Relaxation and Edge Enhancement in NMR MicroscopyJournal of Magnetic Resonance, Series A, 1993
- Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance ExperimentsPhysical Review B, 1954