Development and evaluation of a thallium (I) bromide dosimeter for intracavitary radiotherapy quality assurance
Authors:
- 1 February 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (02) , P02010
Abstract
In intracavitary radiotherapy, incorrect source locations can result in excessive doses to normal tissues. Therefore, it is essential to accurately evaluate the source location. In this study, we investigated a digital line dosimeter based on thallium (I) bromide (TlBr) to improve the existing analogue verification method. Therefore, a polycrystalline TlBr unit cell dosimeter was manufactured, and the measurement performance of iridium-192 (Ir-192) sources was evaluated. We found that the dosimeter's reproducibility satisfied the evaluation criteria of 1.5% with a relative standard deviation of 1.44%. Moreover, the linearity showed excellent results (linear coefficient, R 2 = 0.9999). The distance dependence showed a difference of 0.03 cm at 50% intensity when compared to the inverse square value, whereas the angular dependence showed a large difference when compared to a diode. As the angle increased, the intensity gradually decreased, resulting in a difference of up to 41.9%. These results demonstrate the excellent performance of the TlBr dosimeter. However, because of the significant influence of angular dependence, a measurement distance that minimises this error should be applied when manufacturing line dosimeters in the future.Keywords
This publication has 15 references indexed in Scilit:
- Optical Characterizations of TlBr Single Crystals for Radiation Detection ApplicationsJournal of Radiation Protection and Research, 2016
- A Study on the Dose Distributions in Various Materials from an Ir-192 HDR Brachytherapy SourcePLOS ONE, 2012
- Optically Stimulated Luminescent Dosimetry for High Dose Rate BrachytherapyFrontiers in Oncology, 2012
- Monte Carlo Evaluation for the Effect of Positional Inaccuracy of Source on Patient's Dose in High-Dose-Rate BrachytherapyJournal of the Korean Physical Society, 2009
- Radiation damage effects in Si materials and detectors and rad-hard Si detectors for SLHCJournal of Instrumentation, 2009
- Fundamental x-ray interaction limits in diagnostic imaging detectors: Spatial resolutionMedical Physics, 2008
- High dose-rate brachytherapy source position quality assurance using radiochromic filmMedical Dosimetry, 2007
- High Dose Rate Brachytherapy: Its Clinical Applications and Treatment GuidelinesTechnology in Cancer Research & Treatment, 2004
- Reproducibility study of TLD-100 micro-cubes at radiotherapy dose levelApplied Radiation and Isotopes, 1999
- Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56Medical Physics, 1997