Hydrazine‐induced post‐chemiluminescence phenomenon of permanganate–luminol reaction and its applications
Authors:
- 1 November 2004
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 19 (6) , 328-332
Abstract
The post‐chemiluminescence phenomenon arising from the permanganate–luminol reaction induced by hydrazine and isoniazid was investigated. When hydrazine or isoniazid was injected into the mixture after the end of the reaction of permanganate with alkaline luminol, a new chemiluminescence (CL) reaction was initiated and strong CL signal was detected. A possible CL mechanism is suggested, based upon the studies of the kinetic characteristics of the CL reaction, the UV‐visible spectra, the CL spectra and some other experiments. The present reactions allow the determination of 0.1–10.0 mg/L hydrazine and 0.02–1.0 mg/L isoniazid, with detection limits of 0.03 mg/L and 0.006 mg/L, respectively. The method was applied to the determination of isoniazid in pharmaceutical preparations. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 3 references indexed in Scilit:
- Chemiluminescence behaviour of alkaline earth metal ions in the potassium permanganate–fluorescein reactionLuminescence, 2003
- Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO− as an oxidantThe Analyst, 1999
- Chemiluminescence of LUminol and Related Hydrazides: The Light Emission StepJournal of the American Chemical Society, 1964