Robotic off-pump totally endoscopic coronary artery bypass in the current era: report of 544 patients
- 15 August 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (2) , 439-446
Abstract
: OBJECTIVES: Robotic off-pump totally endoscopic coronary artery bypass (TECAB) is the least invasive form of surgical coronary revascularization. It has proved to be highly effective and safe. Its benefits are well-established and include fewer complications, shorter hospital stay and quicker return to normal activities. TECAB has undergone 2 decades of technological advancement to include multivessel grafting, a beating-heart approach and successful completion in multiple patient groups in experienced hands. The aim of this report was to examine outcomes of robotic off-pump TECAB at our institution over 7 years. METHODS: Data from 544 patients undergoing TECAB between July 2013 and August 2020 were retrospectively examined. The C-Port Flex-A distal anastomotic device was used for the majority of grafts (70%). Yearly follow-up was conducted. Angiographic early patency data were reviewed for patients undergoing hybrid revascularization. RESULTS: The mean age was 66 years, with 1.7% mean STS risk. Fifty-six percentage had multivessel TECAB. There was 1 conversion to sternotomy, and 46% extubation in the Operating Room (OR). Mortality was 0.9%. Early graft patency was 97%. At mid-term follow-up at 38 months, cardiac mortality was 2.7% and freedom from major adverse cardiac events was 92.5%. CONCLUSIONS: We conclude that robotic beating-heart TECAB in the current era is safe and effective with excellent outcomes and comparable early angiographic patency to standard coronary artery bypass grafting surgery when performed frequently by an experienced team. This procedure was completed in our hands both with and without an anastomotic device. Longer-term studies are warranted.Keywords
This publication has 24 references indexed in Scilit:
- Association of Robotic Totally Endoscopic Coronary Artery Bypass Graft Surgery Associated With a Preliminary Cardiac Enhanced Recovery After Surgery Program: A Retrospective AnalysisJournal of Cardiothoracic and Vascular Anesthesia, 2015
- Analysis of the learning curve for beating heart, totally endoscopic, coronary artery bypass graftingThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Five Hundred Cases of Robotic Totally Endoscopic Coronary Artery Bypass Grafting: Predictors of Success and SafetyThe Annals of Thoracic Surgery, 2013
- Quantification and Impact of Untreated Coronary Artery Disease After Percutaneous Coronary InterventionJACC, 2012
- Integrating Coronary Anastomotic Connectors and Robotics Toward a Totally Endoscopic Beating Heart Approach: Review of 120 CasesThe Annals of Thoracic Surgery, 2011
- Beating Heart Totally Endoscopic Coronary Artery BypassThe Annals of Thoracic Surgery, 2010
- On-Pump versus Off-Pump Coronary-Artery Bypass SurgeryNew England Journal of Medicine, 2009
- Quality of Life Improvement after Robotically Assisted Coronary Artery Bypass GraftingCardiology, 2009
- Closed-chest coronary artery bypass grafting on the beating heart with the use of a computer-enhanced surgical robotic systemThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Endoscopic coronary artery bypass grafting with the aid of robotic assisted instrumentsThe Journal of Thoracic and Cardiovascular Surgery, 1999