HKHiroto Kitahara

Hiroto Kitahara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroto Kitahara has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Husam H. Balkhy

    Section of Cardiac Surgery, University of Chicago Medicine, IL, USA

    8 shared publications
  • Hideyuki Shimizu

    Department of Cardiovascular Surgery, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan

    5 shared publications
  • Hiroyuki Kamiya

    Department of Cardiac Surgery, Asahikawa Medical University, Hokkaido, Japan

    5 shared publications
  • Natsuya Ishikawa

    Department of Cardiac Surgery, Asahikawa Medical University, Hokkaido, Japan

    5 shared publications
  • Akihiro Yoshitake

    Department of Cardiovascular Surgery, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan

    4 shared publications
  • Brooke Patel

    Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, IL, USA

    4 shared publications

Latest Publications

  • 550 Robotic Totally Endoscopic Mitral Valve Surgeries Within a Comprehensive Robotic Cardiac Program

    by Hiroto Kitahara, Sarah Nisivaco, Riya Bhasin, Ibraheem Hamzat, Kaitlin Grady, Husam H. Balkhy


  • Open Access

    Edge-to-edge mitral repair for iatrogenic chordal rupture related to Impella 5.0

    by Hiroto Kitahara, Samer Najjar, Sara Ahmed, Phillip Lam, Ajay Kadakkal, Maria Rodrigo, Mark Hofmeyer, Farooq Sheikh, Ezequiel Molina

    Iatrogenic chordal rupture with severe mitral regurgitation is a rare but serious complication associated with the use of Impella device. We present a case of a 47-year-old man with ischemic cardiomyopathy who presented in cardiogenic shock requiring insertion of extracorporeal membrane oxygenation which was subsequently transitioned to an Impella 5.0 device. During Impella support, he developed acute pulmonary edema secondary to newly diagnosed posterior mitral valve chordal rupture and subsequent severe mitral regurgitation. He underwent implantation of a durable left ventricular assist device with concomitant edge-to-edge mitral valve repair through the apex. Transthoracic echocardiography at three month showed mild regurgitation.

  • Ventricular Fibrillatory Arrest: A Safe Option in Robotic Totally Endoscopic Intracardiac Surgery

    by Hiroto Kitahara, Sarah Nisivaco, Ryan Piech, Kaitlin Grady, Husam H. Balkhy


  • Robotic off-pump totally endoscopic coronary artery bypass in the current era: report of 544 patients

    by Husam H Balkhy, Sarah Nisivaco, Hiroto Kitahara, Gianluca Torregrossa, Brooke Patel, Kaitlin Grady, Charocka Coleman

    : OBJECTIVES: Robotic off-pump totally endoscopic coronary artery bypass (TECAB) is the least invasive form of surgical coronary revascularization. It has proved to be highly effective and safe. Its benefits are well-established and include fewer complications, shorter hospital stay and quicker return to normal activities. TECAB has undergone 2 decades of technological advancement to include multivessel grafting, a beating-heart approach and successful completion in multiple patient groups in experienced hands. The aim of this report was to examine outcomes of robotic off-pump TECAB at our institution over 7 years. METHODS: Data from 544 patients undergoing TECAB between July 2013 and August 2020 were retrospectively examined. The C-Port Flex-A distal anastomotic device was used for the majority of grafts (70%). Yearly follow-up was conducted. Angiographic early patency data were reviewed for patients undergoing hybrid revascularization. RESULTS: The mean age was 66 years, with 1.7% mean STS risk. Fifty-six percentage had multivessel TECAB. There was 1 conversion to sternotomy, and 46% extubation in the Operating Room (OR). Mortality was 0.9%. Early graft patency was 97%. At mid-term follow-up at 38 months, cardiac mortality was 2.7% and freedom from major adverse cardiac events was 92.5%. CONCLUSIONS: We conclude that robotic beating-heart TECAB in the current era is safe and effective with excellent outcomes and comparable early angiographic patency to standard coronary artery bypass grafting surgery when performed frequently by an experienced team. This procedure was completed in our hands both with and without an anastomotic device. Longer-term studies are warranted.


  • Edge‐to‐edge mitral repair for iatrogenic chordal rupture related to Impella 5.0

    by Hiroto Kitahara, Samer Najjar, Sara Ahmed, Phillip Lam, Ajay Kadakkal, Maria Rodrigo, Mark Hofmeyer, Farooq Sheikh, Ezequiel Molina

    Iatrogenic chordal rupture with severe mitral regurgitation is a rare but serious complication associated with the use of Impella device. We present a case of a 47‐year‐old man with ischemic cardiomyopathy who required insertion of an Impella 5.0 device. During Impella support, he developed acute pulmonary edema secondary to newly diagnosed posterior mitral valve chordal rupture and subsequent severe mitral regurgitation. He underwent implantation of a durable left ventricular assist device with concomitant edge‐to‐edge mitral valve repair through the apex.


  • Angiographic patency after robotic beating heart totally endoscopic coronary artery bypass grafting facilitated by automated distal anastomotic connectors

    by Husam H Balkhy, Sandeep Nathan, Gianluca Torregrossa, Hiroto Kitahara, Sarah Nisivaco, Mackenzie McCrorey, Brooke Patel

    OBJECTIVES: Robotic totally endoscopic coronary artery bypass (TECAB) on the beating heart has been facilitated in our experience using distal coronary anastomotic connectors. In this study, we retrospectively reviewed graft patency in all robotic TECAB patients who underwent formal angiography at our current institution over a 5-year period. METHODS: Between July 2013 and June 2018, 361 consecutive patients underwent robotic beating-heart TECAB. Of these patients, 121 had a follow-up angiogram, which assessed graft patency. Eighty-four patients had an angiogram as part of planned hybrid procedures and 37 patients underwent an unplanned angiogram for clinical indications. Retrospective analysis of angiographic patency and clinical outcomes was performed. RESULTS: The mean Society of Thoracic Surgeons predicted risk of mortality was 1.8%. Single-vessel bypass was performed in 40 (33%) patients and multivessel grafting in 81 (67%). Average flow (ml/min) and pulsatility index in the grafts was 74.7 ± 39.1 and 1.42 ± 0.52, respectively. The number of grafts evaluated was 204 (130 left internal mammary artery and 74 right internal mammary artery grafts). The median time to angiography was 1.0 and 16.0 months and graft patency was 98% and 91% in the hybrid and non-hybrid groups, respectively. Overall graft patency was 95.6% (left internal mammary artery = 96%; right internal mammary artery = 93%). Left internal mammary artery to left anterior descending artery graft patency was 97%. Clinical follow-up was available for 316 (88%) patients at mean 22.5 ± 15.1 months. Freedom from major adverse cardiac events at 2 years was 92%. CONCLUSIONS: In this consecutive series of patients undergoing formal angiography after robotic single and multivessel TECAB, we found satisfactory graft patency and 2-year clinical outcomes. Longer-term follow-up is warranted.


  • Successful Conservative Management of Inferior Mesenteric Artery Aneurysm with Arteriovenous Fistula: A Case Report

    by Shingo Kunioka, Hiroto Kitahara, Noriyuki Yuasa, Miri Fujita, Norifumi Otani, Hiroyuki Kamiya


  • Robotic totally endoscopic beating-heart bypass to the right coronary artery: first worldwide experience

    by Husam H Balkhy, Hiroto Kitahara, Brian Mitzman, Sarah Nisivaco

    OBJECTIVES: Left coronary vessels are the usual targets in totally endoscopic coronary artery bypass (TECAB). Grafting of the right coronary artery (RCA) has been limited using this approach because of anatomic and technical difficulties. We report a first series of robotic beating-heart TECAB to the RCA via a right-chest approach. METHODS: From July 2013 to April 2019, patients who underwent robotic beating-heart TECAB with the right internal mammary artery to the RCA were reviewed. Port placement in the right chest mirrored standard left-sided ports. Indications for right internal mammary artery to RCA bypass were RCA disease not amenable to percutaneous intervention and anomalous origin of the RCA. RESULTS: Right internal mammary artery–RCA bypass was performed in 16 patients (mean age 60.6 ± 13.5, 75% male). All cases were completed without conversion to sternotomy or mini-thoracotomy. Cardiopulmonary bypass was required in 1 patient to expose the posterior descending artery. Mean procedure time was 223 ± 49 min, with half of the patients extubated in the operating room (50%). Mean intraoperative transit-time graft flow was 87.0 ± 19.3 ml/min, and a pulsatility index of 1.2 ± 0.2. Mean length of stay was 2.3 ± 1.2 days. No mortality was observed at mean follow-up time of 20.6 months. One patient required repeat RCA revascularization for progression of native disease 43.7 months after the surgery. CONCLUSIONS: Robotic beating-heart TECAB for isolated RCA disease is a feasible operation in selected patients. This technique is possible even for the posterior descending artery.


  • Predictors of blood transfusion use in robotic beating‐heart totally endoscopic coronary artery bypass with anastomotic connectors

    by Hiroto Kitahara, Mackenzie McCrorey, Brooke Patel, Sarah Nisivaco, Husam H Balkhy

    Background We sought to identify the independent predictors of blood transfusion requirement in robotic beating‐heart patients with totally endoscopic coronary artery bypass (TECAB). Methods We retrospectively reviewed patients undergoing TECAB with distal anastomotic connectors from July 2013 to May 2017 at our institution. The cohorts were divided into patients who received a blood transfusion (BT group) and patients who did not (non‐blood transfusion [NBT] group). Results Two‐hundred seventy‐four consecutive patients underwent TECAB, and 47 patients (17%; BT group) received BT. The BT group had a lower preoperative hemoglobin level and a higher rate of preoperative risk profiles and higher society of thoracic surgeons (STS) predicted the risk of mortality. Kaplan Meier analysis showed decreased 1‐year survival in the BT group compared with the NBT group (90.9% vs 96.4%; logrank, 0.017). The Youden index identified a preoperative hemoglobin cutoff value of 12.2 g/dL (sensitivity 60.9%, specificity 79.3%) and operative time of 300 minutes (sensitivity 61.7%, specificity 59.0%) for BT requirement. Multivariate logistic regression analysis identified a preoperative hemoglobin 300 minutes (odds ratio, 2.15; 95% confidence interval, 1.07‐4.33) as independent factors associated with BT requirement. Conclusions We found that preoperative hemoglobin and operative time were independent predictors of BT requirement during robotic beating‐heart TECAB. These data would help to select patients to minimize perioperative BT as well as predict outcomes after this procedure.