Optical Coherence Elastography-Based Corneal Strain Imaging During Low-Amplitude Intraocular Pressure Modulation
Authors:
Open Access
- 31 January 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 7, 453
Abstract
Purpose: Optical coherence elastography (OCE) is a promising technique for high-resolution strain imaging in ocular tissues. A major strain-inducing factor in the eye is intraocular pressure (IOP), with diurnal physiological fluctuations reaching up to 5 mmHg. We study herein low-amplitude IOP modulation to assess local corneal strain patterns. Methods: Ex vivo porcine eye globes were adjusted to an initial IOP of 15 mmHg and subsequently 25 mmHg. Corneal strain was induced by two subsequent pressure cycles, in which IOP was first increased and then decreased, each by a total of 5 mmHg. Two-dimensional optical coherence tomography (2D-OCT) B-scans were recorded after each loading step. Axial strain maps were obtained from magnitude and phase changes and supra-pixel displacements from cross-correlation. The strain detection sensitivity was evaluated in an isotropic material. Results: Deformations arising from a single 1-mmHg step could be resolved. The largest strain amplitudes (5.11·10−3) were observed in the posterior stroma at a low initial IOP. Strain amplitude was 1.34 times higher at 15 mmHg than at 25 mmHg (p = 0.003). Upon IOP increase, the anterior cornea was compressed, whereas the posterior cornea showed axial expansion. Both morphological images and strain maps were sensitive to postmortem time. Strains that are larger than 2.44·10−5 could be reliably measured. Conclusions: Low-amplitude IOP modulation, similar to diurnal physiological changes, induced measurable deformations in corneal tissue. Axial strain maps permit a localized comparison of the corneal biomechanical response. Small-strain OCE can likely be extended to other domains.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (PZ00P2_174113)
This publication has 38 references indexed in Scilit:
- Corneal Biomechanical Changes after Collagen Cross-Linking from Porcine Eye Inflation ExperimentsInvestigative Ophthalmology & Visual Science, 2010
- Effects of Altered Corneal Stiffness on Native and Postoperative LASIK Corneal Biomechanical Behavior: A Whole-eye Finite Element AnalysisJournal of Refractive Surgery, 2009
- Signalling cascades in mechanotransduction: cell–matrix interactions and mechanical loadingScandinavian Journal of Medicine & Science in Sports, 2009
- Can We Measure Corneal Biomechanical Changes After Collagen Cross-Linking in Eyes With Keratoconus?-A Pilot StudyCornea, 2009
- On the elastic moduli and compliances of transversely isotropic and orthotropic materialsJournal of Mechanics of Materials and Structures, 2008
- Assessment of the epithelium's contribution to corneal biomechanicsExperimental Eye Research, 2008
- Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic EyesInvestigative Ophthalmology & Visual Science, 2007
- Comparative study of corneal strip extensometry and inflation testsJournal of The Royal Society Interface, 2005
- Diurnal intraocular pressure variations: an analysis of 690 diurnal curves.British Journal of Ophthalmology, 1992
- Biomechanical properties of keratoconus and normal corneasExperimental Eye Research, 1980