Performance of Centargo: A Novel Piston-Based Injection System for High Throughput in CE CT
Open Access
- 1 April 2022
- journal article
- research article
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 15, 79-87
Abstract
Purpose: To compare an investigational device (MEDRAD® Centargo CT Injection System, “Centargo”) to the currently available MEDRAD® Stellant CT Injection System (“Stellant”), in terms of efficiency, injector performance, and user satisfaction. Patients and Methods: A total of 425 patients at two sites were enrolled; 198 patients in phase one, a randomized study (98 Stellant and 100 Centargo). The second observational phase included 227 patients who were injected with Centargo. Phase one recorded times for setup, disassembly, and patient changeovers. Demographic data, subjective image quality, and injection parameters were collected. Phase two assessed usability via a questionnaire provided to all end-users of both systems (radiographers). Results: Patient changeover times were statistically significantly faster with Centargo (15.4s ± 8.7s vs 53.7s ± 19.6s, p < 0.001). Centargo day-setup times were similar to Stellant (138.1s ± 92s vs 151.8s ± 30.6s, p = 0.33) and end-of-day-disassembly times were significantly slower (60.6s ± 27s vs 17.1s ± 12.9s, p < 0.001). Based on four different scenarios modelling patient throughput, the projected time savings with Centargo over Stellant was 40– 63%, with the highest efficiency improvements for higher throughputs and the use of larger contrast medium bottles. Both Centargo and Stellant usability averaged between “Very Easy” and “Easy” in all responses to the questionnaire. There were no instances of interrupted injections due to communication loss or detected air and no insufficient images due to injector performance. No safety issues were identified. Conclusion: Centargo was able to demonstrate improved efficiency as compared to Stellant while maintaining injector performance and high usability scores.Keywords
This publication has 11 references indexed in Scilit:
- Piston-Based vs Peristaltic Pump-Based CT Injector Systems2019
- Contrast opacification on thoracic CT angiography: challenges and solutionsInsights into Imaging, 2016
- Evolution in Computed TomographyInvestigative Radiology, 2015
- Pressure injectors for radiologists: A review and what is newIndian Journal of Radiology and Imaging, 2015
- Syringeless power injector versus dual-syringe power injector: economic evaluation of user performance, the impact on contrast enhanced computed tomography (CECT) workflow exams, and hospital costsMedical Devices: Evidence and Research, 2013
- Impact of Iodine Delivery Rate with Varying Flow Rates on Image Quality in Dual-Energy CT of Patients with Suspected Pulmonary EmbolismAcademic Radiology, 2013
- Comparison of Dual-Syringe and Syringeless Power Injectors in Outpatient MDCT Practice: Impact on the Operator's Performance, CT Workflow, and Operation CostJournal of the American College of Radiology, 2012
- Automatic MDCT Injectors: Hygiene and Efficiency of Disposable, Prefilled, and Multidosing Roller Pump Systems in Clinical RoutineAmerican Journal of Roentgenology, 2011
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- Contrast Agents in X-Ray Computed Tomography and Its Applications in OncologyAnti-Cancer Agents in Medicinal Chemistry, 2007