Latest Publications

  • Open Access

    Critical but commonly neglected factors that affect contrast medium administration in CT

    by Michael C. McDermott, Joachim E. Wildberger, Kyongtae T. Bae

    Objective: Past decades of research into contrast media injections and optimization thereof in radiology clinics have focused on scan acquisition parameters, patient-related factors, and contrast injection protocol variables. In this review, evidence is provided that a fourth bucket of crucial variables has been missed which account for previously unexplained phenomena and higher-than-expected variability in data. We propose how these critical factors should be considered and implemented in the contrast-medium administration protocols to optimize contrast enhancement. Methods: This article leverages a combination of methodologies for uncovering and quantifying confounding variables associated with or affecting the contrast-medium injection. Engineering benchtop equipment such as Coriolis flow meters, pressure transducers, and volumetric measurement devices are combined with small, targeted systematic evaluations querying operators, equipment, and the physics and fluid dynamics that make a seemingly simple task of injecting fluid into a patient a complex and non-linear endeavor. Results: Evidence is presented around seven key factors affecting the contrast-medium injection including a new way of selecting optimal IV catheters, degraded performance from longer tubing sets, variability associated with the mechanical injection system technology, common operator errors, fluids exchanging places stealthily based on gravity and density, wasted contrast media and inefficient saline flushes, as well as variability in the injected flow rate vs. theoretical expectations. Conclusion: There remain several critical, but not commonly known, sources of error associated with contrast-medium injections. Elimination of these hidden sources of error where possible can bring immediate benefits and help to drive standardized and optimized contrast-media injections. Critical relevance statement: This review brings to light the commonly neglected/unknown factors negatively impacting contrast-medium injections and provides recommendations that can result in patient benefits, quality improvements, sustainability increases, and financial benefits by enabling otherwise unachievable optimization. Key Points: How IV contrast media is administered is a rarely considered source of CT imaging variability. IV catheter selection, tubing length, injection systems, and insufficient flushing can result in unintended variability. These findings can be immediately addressed to improve standardization in contrast-enhanced CT imaging. Graphical


  • Open Access

    Countering Calcium Blooming With Personalized Contrast Media Injection Protocols

    by Michael C. BSc McDermott, Thomas Bsc Sartoretti, Lion Msc Stammen, Bibi Martens, Gregor Jost, Hubertus Pietsch, Ralf Gutjahr, Bernhard Schmidt, Thomas G. Flohr, Hatem Md Alkadhi, et al.

    Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. Materials and Methods: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. Results: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R 2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. Conclusions: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.


  • Open Access

    Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries

    by Thomas Sartoretti, Michael C. McDermott, Lion Stammen, Bibi Martens, Lukas J. Moser, Gregor Jost, Hubertus Pietsch, Ralf Gutjahr, Tristan Nowak, Bernhard Schmidt, et al.

    Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.


  • Open Access

    New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT

    by Gregor Jost, Michael BSc McDermott, Ralf Gutjahr, Tristan Nowak, Bernhard Schmidt, Hubertus Pietsch

    The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task. A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role. The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included. Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.


  • Open Access

    Photon-counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

    by Thomas Sartoretti, Michael McDermott, Victor Mergen, André Euler, Bernhard Schmidt, Gregor Jost, Joachim E Wildberger, Hatem Alkadhi

    Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA). Methods: CCTA with PCD-CT (prospective ECG-triggering, 120 kVp, automatic tube current modulation) was performed in a high-end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR-off) and with all quantum iterative reconstruction (QIR) levels (QIR-1 to 4). In the phantom, noise power spectrum, vessel attenuation, contrast-to-noise-ratio (CNR), and vessel sharpness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronary artery plaque delineation on 5-point Likert scales in patients. Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR-4 to 40 keV QIR-off. Reconstructions at 40 keV QIR-4 exhibited the highest CNR (46.1 ± 1.8), vessel sharpness (425 ± 42 ∆HU/mm), and vessel attenuation (1098 ± 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR-3 and QIR-4 images received the best scores (p < 0.001). Conclusion: Forty keV VMI with QIR-4 significantly improved image quality of CCTA with PCD-CT. Advances in knowledge: PCD-CT at 40 keV and QIR-4 improves image quality of CCTA.


  • Open Access

    Performance of Centargo: A Novel Piston-Based Injection System for High Throughput in CE CT

    by Corey A Kemper, Casper Mihl, Bibi Martens, Michael C McDermott, Babs Mf Hendriks

    Purpose: To compare an investigational device (MEDRAD® Centargo CT Injection System, “Centargo”) to the currently available MEDRAD® Stellant CT Injection System (“Stellant”), in terms of efficiency, injector performance, and user satisfaction. Patients and Methods: A total of 425 patients at two sites were enrolled; 198 patients in phase one, a randomized study (98 Stellant and 100 Centargo). The second observational phase included 227 patients who were injected with Centargo. Phase one recorded times for setup, disassembly, and patient changeovers. Demographic data, subjective image quality, and injection parameters were collected. Phase two assessed usability via a questionnaire provided to all end-users of both systems (radiographers). Results: Patient changeover times were statistically significantly faster with Centargo (15.4s ± 8.7s vs 53.7s ± 19.6s, p < 0.001). Centargo day-setup times were similar to Stellant (138.1s ± 92s vs 151.8s ± 30.6s, p = 0.33) and end-of-day-disassembly times were significantly slower (60.6s ± 27s vs 17.1s ± 12.9s, p < 0.001). Based on four different scenarios modelling patient throughput, the projected time savings with Centargo over Stellant was 40– 63%, with the highest efficiency improvements for higher throughputs and the use of larger contrast medium bottles. Both Centargo and Stellant usability averaged between “Very Easy” and “Easy” in all responses to the questionnaire. There were no instances of interrupted injections due to communication loss or detected air and no insufficient images due to injector performance. No safety issues were identified. Conclusion: Centargo was able to demonstrate improved efficiency as compared to Stellant while maintaining injector performance and high usability scores.


  • Open Access

    Low kV Computed Tomography of Parenchymal Abdominal Organs—A Systematic Animal Study of Different Contrast Media Injection Protocols

    by Daniel Overhoff, Gregor Jost, Michael McDermott, Olaf Weber, Hubertus Pietsch, Stefan O. Schoenberg, Ulrike Attenberger

    Objectives: To evaluate multiphase low kV computed tomography (CT) imaging of the abdomen with reduced contrast media (CM) dose using different injection protocols. Methods: Two injection protocols were evaluated for use with low kV (80 kV) multiphase abdominal imaging in comparison to the standard procedure acquired at 120 kV (500 mgI/kg; 5 mL/s). This evaluation was conducted in a highly standardized animal study (5 Goettingen minipigs). The low kV protocols consisted of (a) a single-flow (SF) injection with 40% reduced CM dose and injection rate (300 mgI/kg; 3 mL/s) and (b) a DualFlow (DF) injection protocol consisting of 60%/40% contrast to saline ratio administered at 5 mL/s. Dynamic CT was first performed within representative liver regions to determine optimal contrast phases, followed by evaluation of the three protocols in multiphase abdominal CT imaging. The evaluation criteria included contrast enhancement (CE) of abdominal organs and vasculature. Results: The 80 kV DF injection protocol showed similar CE of the abdominal parenchymatous organs and vessels to the 120 kV reference and the 80 kV SF protocol. Hepatic parenchyma showed comparable CT values for all contrast phases. In particular, in the portal venous parenchymal phase, the 80 kV DF protocol demonstrated higher hepatic parenchymal enhancement; however, results were statistically non-significant. Similarly, CE of the kidney, pancreas, and abdominal arterial/venous vessels showed no significant differences between injection protocols. Conclusions: Adapted SF and DF injection protocols with reduced IDR/iodine load offer the potential to calibrate optimal CM doses to the tube voltage in abdominal multiphase low kV CT imaging. The data suggest that the DF approach allows the use of predefined injection protocols and adaption of the contrast to saline ratio to an individualized kV setting and yields the potential for patient-individualized CM adaption.


  • Open Access

    Proactive Air Management in CT Power Injections: A Comprehensive Approach to Reducing Air Embolization

    by Michael C. McDermott, William R. Barone, Corey Ann Kemper

    Objective: Venous air embolism as a complication of contrast media administration from power injection systems in CT is found to occur in 7%-55% of patients, impacting patient safety, diagnostic image quality, workflow efficiency, and patient and radiographer satisfaction. This study reviews the challenges associated with reactive air management approaches employed on contemporary systems, proposes a novel air management approach using proactive methods, and compares the impact of reactive and proactive approaches on injected air volumes under simulated clinical use. Methods: Injected air volumes from three power injection systems were measured under simulated clinical use via custom air trap fixture. Two of the systems employed reactive air management approaches, while a new system implemented the proposed proactive air management approach. Results: The proactive system injected significantly less air (average of 0.005mL±0.006mL with a maximum of 0.017mL) when compared to two systems with reactive approaches (averages of 0.130mL±0.082mL and 0.106mL±0.094mL with maximums of 0.259mL and 0.311mL, respectively) (p<0.05). CT images were taken of static and dynamic 0.1mL air bubbles inside of a vascular phantom, both of which were clearly visible. Additionally, the dynamic bubble was shown to introduce image artifacts similar to those observed clinically. Conclusion: Comparison of the injected air volumes show that a system with a proactive air management approach injected significantly less air compared to tested systems employing reactive approaches. Significance: The results indicate that the use of a proactive approach could significantly reduce the prevalence of observable, and potentially artifact-inducing, venous air embolism in contrast-enhanced CT procedures.


  • Open Access

    Impact of CT Injector Technology and Contrast Media Viscosity on Vascular Enhancement: Evaluation in a Circulation Phantom

    by Michael McDermott, Corey Kemper, William Barone, Gregor Jost, Jan Endrikat

    Objective: To assess the impact of piston-based vs peristaltic injection system technology and contrast media viscosity on achievable iodine delivery rates (IDRs) and vascular enhancement in a pre-clinical study. Methods: Four injectors were tested: MEDRAD® Centargo, MEDRAD® Stellant, CT Exprès®, and CT motion™ using five contrast media [iopromide (300 and 370 mgI ml−1), iodixanol 320 mgI ml−1, iohexol 350 mgI ml−1, iomeprol 400 mgI ml−1]. Three experiments were performed evaluating achievable IDR and corresponding enhancement in a circulation phantom. Results: Experiment I: Centargo provided the highest achievable IDRs with all tested contrast media (p < 0.05). Iopromide 370 yielded the highest IDR with an 18G catheter (3.15 gI/s); iopromide 300 yielded the highest IDR with 20G (2.70 gI/s) and 22G (1.65 gI/s) catheters (p < 0.05). Experiment II: with higher achievable IDRs, piston-based injectors provided significantly higher peak vascular enhancement (up to 48% increase) than the peristaltic injectors with programmed IDRs from 1.8 to 2.4 gI/s (p < 0.05). Experiment III: with programmed IDRs (e.g. 1.5 gI/s) achievable by all injection systems, Centargo, with sharper measured bolus shape, provided significant increases in enhancement of 34–73 HU in the pulmonary artery with iopromide 370 (p < 0.05). Conclusion: The tested piston-based injection systems combined with low viscosity contrast media provide higher achievable IDRs and higher peak vascular enhancement than the tested peristaltic-based injectors. With equivalent IDRs, Centargo provides higher peak vascular enhancement due to improved bolus shape. Advances in knowledge: This paper introduces a new parameter to compare expected performance among contrast media: the concentration/viscosity ratio. Additionally, it demonstrates previously unexplored impacts of bolus shape on vascular enhancement.


  • Nanogel-Mediated RNAi Against Runx2 and Osx Inhibits Osteogenic Differentiation in Constitutively Active BMPR1A Osteoblasts

    by Arun R. Shrivats, Michael C. McDermott, Molly Klimak, Saadyah E. Averick, Haichun Pan, Krzysztof Matyjaszewski, Yuji Mishina, Jeffrey O. Hollinger

    Trauma-induced heterotopic ossification (HO) and fibrodysplasia ossificans progressiva (FOP) are acquired and genetic variants of pathological bone formation occurring in soft tissues. Conventional treatment modalities target the inflammatory processes preceding bone formation. We investigated the development of a prophylaxis for heterotopic bone formation by addressing the biological basis for HO – dysregulation in the bone morphogenetic protein (BMP) signaling pathway. We previously reported the synthesis of cationic nanogel nanostructured polymers (NSPs) for efficient delivery of short interfering ribonucleic acids (siRNAs) and targeted gene silencing. Results suggested that nanogel:siRNA weight ratios of 1:1 and 5:1 silenced Runx2 and Osx gene expression in primary mouse osteoblasts with a constitutively active (ca) BMP Receptor 1A (BMPR1A) by the Q233D mutation. Repeated RNAi treatments over 14 days significantly inhibited alkaline phosphatase activity in caBMPR1A osteoblasts. Hydroxyapatite (HA) deposition was diminished over 28 days in culture, though complete suppression of HA deposition was not achieved. Outcome data suggested minimal cytotoxicity of nanogel-based RNAi therapeutics, and the multistage disruption of BMP-induced bone formation processes. This RNAi based approach to impeding osteoblastic differentiation and subsequent bone formation may form the basis of a clinical therapy for heterotopic bone formation.