An Atraumatic Mock Loop for Realistic Hemocompatibility Assessment of Blood Pumps
- 22 December 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1651-1662
Abstract
Objective: Conventional mock circulatory loops (MCLs) cannot replicate realistic hemodynamic conditions without inducing blood trauma. This constrains in-vitro hemocompatibility examinations of blood pumps to static test loops that do not mimic clinical scenarios. This study aimed at developing an atraumatic MCL based on a hardware-in-the-loop concept (H-MCL) for realistic hemocompatibility assessment. Methods: The H-MCL was designed for 450 $\pm$ 50 ml of blood with the polycarbonate reservoirs, the silicone/polyvinyl-chloride tubing, and the blood pump under investigation as the sole blood-contacting components. To account for inherent coupling effects a decoupling pressure control was derived by feedback linearization, whereas the level control was addressed by an optimization task to overcome periodic loss of controllability. The HeartMate 3 was showcased to evaluate the H-MCL's accuracy at typical hemodynamic conditions. To verify the atraumatic properties of the H-MCL, hemolysis (bovine blood, n = 6) was evaluated using the H-MCL in both inactive (static) and active (minor pulsatility) mode, and compared to results achieved in conventional loops. Results: Typical hemodynamic scenarios were replicated with marginal coupling effects and root mean square error (RMSE) below 1.74 $\pm$ 1.37 mmHg while the fluid level remained within $\pm$ 4% of its target value. The normalized indices of hemolysis (NIH) for the inactive H-MCL showed no significant differences to conventional loops ( $\Delta$ NIH = −1.6 mg/100 L). Further, no significant difference was evident between the active and inactive mode in the H-MCL ( $\Delta$ NIH = +0.3 mg/100 L). Conclusion and significance: Collectively, these findings indicated the H-MCL's potential for in-vitro hemocompatibility assessment of blood pumps within realistic hemodynamic conditions, eliminating inherent setup-related risks for blood trauma.Keywords
All Related Versions
Funding Information
- Austrian Federal Ministry of Labour and Economy
- Österreichische Nationalstiftung für Forschung, Technologie und Entwicklung
- Christian Doppler Forschungsgesellschaft
This publication has 18 references indexed in Scilit:
- Validation of a Miniaturized Test Loop for the Assessment of Human Blood Damage by Continuous-Flow Left-Ventricular Assist DevicesAnnals of Biomedical Engineering, 2021
- The Society of Thoracic Surgeons Intermacs 2020 Annual ReportThe Annals of Thoracic Surgery, 2021
- Blood trauma potential of the HeartWare Ventricular Assist Device in pediatric patientsThe Journal of Thoracic and Cardiovascular Surgery, 2020
- Eighth annual INTERMACS report: Special focus on framing the impact of adverse eventsThe Journal of Heart and Lung Transplantation, 2017
- Normalisation of Haemodynamics in Patients with End-stage Heart Failure with Continuous-flow Left Ventricular Assist Device TherapyHeart, Lung and Circulation, 2014
- Unexpected Abrupt Increase in Left Ventricular Assist Device ThrombosisNew England Journal of Medicine, 2014
- An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trialThe Journal of Heart and Lung Transplantation, 2014
- A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental ValidationASAIO Journal, 2008
- Partload operation, impact of 3-D flow phenomena performance2007
- Pneumatic Drives2007