Short stem hip arthroplasty with the optimys prosthesis is a safe and effective option for obese patients: a mid-term follow-up multicenter study
Authors:
- Nico HinzNHNico Hinz
- Giulia MarsoniGMGiulia Marsoni
- Hagen MittelstädtHMHagen Mittelstädt
- Falk SonnabendFSFalk Sonnabend
- Karsten WallrothKWKarsten Wallroth
- Carsten JohlCJCarsten Johl
- Ulrich WeigertUWUlrich Weigert
- Conrad AnderlCAConrad Anderl
- Reinhold OrtmaierROReinhold Ortmaier
- Natividad ZelenyNZNatividad Zeleny
- Arndt-Peter SchulzASArndt-Peter Schulz
Open Access
- 4 November 2023
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (3) , 1401-1414
Abstract
Introduction: Short stems are a valuable option in young patients undergoing total hip arthroplasty (THA) because of their bone stock preserving properties facilitating revision hip arthroplasty. Although the effect of obesity on conventional THA is well studied, data about short stem THA in obese patients are lacking. Therefore, this study aimed to investigate the influence of obesity on complications, revisions, and outcome after short stem THA. Materials and methods: This multicenter, observational cohort study included patients undergoing short stem THA with the optimys prosthesis. Follow-up examinations were performed at specific intervals up to 7 years postoperatively. Operation characteristics, general and specific complications, revisions, VAS rest pain, VAS load pain, VAS patient satisfaction, and Harris Hip Score (HHS) were recorded and statistically compared between obese (BMI ≥ 30 kg/m2) and non-obese (BMI < 30 kg/m2) patients. Results: Of the 224 patients included with a mean follow-up of 87.2 months (range 81.9–104.0), 69 were assigned to the OB group and 155 to the non-OB group. A minimally invasive approach was significantly less often selected in obese patients (p = 0.049), whereas operating time and length of hospital stay were not significantly different. The rate of general and specific complications did not significantly differ between both groups. Survival of the optimys prosthesis was 99.1% at 7-year follow-up and one patient per group had to undergo revision surgery. VAS rest pain, load pain, and satisfaction improved from preoperatively to postoperatively in both groups without a significant difference between both groups. While the HHS was improved from preoperatively to postoperatively, obese patients showed a significantly lower HHS at the 7-year follow-up (p = 0.01) but still exhibited an excellent scoring above the PASS threshold. Conclusion: Short stem THA with the optimys prosthesis is a safe and effective option also in obese patients with an excellent clinical outcome and a low complication rate.Keywords
Funding Information
- Mathys Orthopedics GmbH, Germany
This publication has 80 references indexed in Scilit:
- Does body mass index affect clinical outcome post-operatively and at five years after primary unilateral total hip replacement performed for osteoarthritis?The Journal of Bone and Joint Surgery. British volume, 2011
- Epidemiology of Knee and Hip Arthroplasty: A Systematic Review§The Open Orthopaedics Journal, 2011
- Evaluating comorbidities in total hip and knee arthroplasty: available instrumentsJournal of Orthopaedics and Traumatology, 2010
- Minimally invasive versus conventional exposure for total hip arthroplasty: a systematic review and meta-analysis of clinical and radiological outcomesInternational Orthopaedics, 2010
- Incidence of Lateral Femoral Cutaneous Nerve Neuropraxia After Anterior Approach Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030Clinical Orthopaedics and Related Research, 2009
- The relationship between obesity and the age at which hip and knee replacement is undertakenThe Journal of Bone and Joint Surgery. British volume, 2008
- Differences in outcomes of obese women and men undergoing primary total hip arthroplastyArthritis Care & Research, 2007
- The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCAThe Journal of Bone and Joint Surgery. British volume, 1999
- Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1999