HMHagen Mittelstaedt

Hagen Mittelstaedt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hagen Mittelstaedt has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?

    by Felix Olk, Bernd Bittersohl, Jürgen Babisch, Hagen Mittelstädt, Marcus Jäger, Rüdiger Krauspe, Christoph Zilkens

    Introduction: Short-stem total hip arthroplasty (THA) has gained popularity due to its bone-preserving properties and improved physiological load transmission to the proximal femur. Despite these advantages, the ability of short-stem implants to reliably restore leg length and offset remains debated. This study evaluates whether a single offset implant is sufficient for accurate anatomical reconstruction or if multiple offset options are necessary. Material and methods: A total of 148 anteroposterior pelvic radiographs of patients scheduled for short-stem THA were analysed using MediCAD ® software. Femoral offset and leg length were measured, and the accuracy of anatomical reconstruction was assessed within a 5-mm target range. Comparisons were made between a single offset (130°) implant and a dual-offset system (130° and 119°) using the McNemar-Bowker test. Results: With a single 130° CCD (Caput-collum-diaphyseal) offset implant, 55.7% (82/148) of cases achieved satisfactory leg length and offset restoration. The use of a dual-offset system improved accuracy to 79.1% (117/148), demonstrating a statistically significant advantage ( p < 0.001). Discussion: The study highlights the need for at least two CCD-angle-offset combinations in short-stem THA to address anatomical variability. A dual-offset system enhances accuracy, reduces biomechanical imbalances, and therefore we expect improvements in clinical outcomes, particularly in teaching hospitals where standardization is essential.

  • Open Access

    Short stem hip arthroplasty with the optimys prosthesis is a safe and effective option for obese patients: a mid-term follow-up multicenter study

    by Nico Hinz, Giulia Marsoni, Hagen Mittelstädt, Falk Sonnabend, Karsten Wallroth, Carsten Johl, Ulrich Weigert, Conrad Anderl, Reinhold Ortmaier, Natividad Zeleny, et al.

    Introduction: Short stems are a valuable option in young patients undergoing total hip arthroplasty (THA) because of their bone stock preserving properties facilitating revision hip arthroplasty. Although the effect of obesity on conventional THA is well studied, data about short stem THA in obese patients are lacking. Therefore, this study aimed to investigate the influence of obesity on complications, revisions, and outcome after short stem THA. Materials and methods: This multicenter, observational cohort study included patients undergoing short stem THA with the optimys prosthesis. Follow-up examinations were performed at specific intervals up to 7 years postoperatively. Operation characteristics, general and specific complications, revisions, VAS rest pain, VAS load pain, VAS patient satisfaction, and Harris Hip Score (HHS) were recorded and statistically compared between obese (BMI ≥ 30 kg/m2) and non-obese (BMI < 30 kg/m2) patients. Results: Of the 224 patients included with a mean follow-up of 87.2 months (range 81.9–104.0), 69 were assigned to the OB group and 155 to the non-OB group. A minimally invasive approach was significantly less often selected in obese patients (p = 0.049), whereas operating time and length of hospital stay were not significantly different. The rate of general and specific complications did not significantly differ between both groups. Survival of the optimys prosthesis was 99.1% at 7-year follow-up and one patient per group had to undergo revision surgery. VAS rest pain, load pain, and satisfaction improved from preoperatively to postoperatively in both groups without a significant difference between both groups. While the HHS was improved from preoperatively to postoperatively, obese patients showed a significantly lower HHS at the 7-year follow-up (p = 0.01) but still exhibited an excellent scoring above the PASS threshold. Conclusion: Short stem THA with the optimys prosthesis is a safe and effective option also in obese patients with an excellent clinical outcome and a low complication rate.


  • Subsidence analysis of a cementless short stem THA using EBRA-FCA - A seven-year prospective multicentre study

    by Hagen Mittelstaedt, Conrad Anderl, Reinhold Ortmaier, Carsten Johl, Thomas Krüger, Karsten Wallroth, Ulrich Weigert, Jan C. Schagemann


  • Open Access

    Correlation of the Histological ICRS II Score and the 3D MOCART Score for the Analysis of Aged Osteochondral Regenerates in a Large Animal Model

    by J.C. Schagemann, L. Galle, J. Gille, A. Frydrychowicz, G. Welsch, G. Salzmann, A. Paech, H. Mittelstaedt

    Objective: Reliable outcome measures are essential to predict the success of cartilage repair techniques. Histology is probably the gold standard, but magnetic resonance imaging (MRI) has the potential to decrease the need for invasive histological biopsies. The 3D magnetic resonance observation of cartilage repair tissue (MOCART) score is a reliable yet elaborate tool. Moreover, literature is controversial concerning the correlation of histology and MRI. Design: To test the applicability of the International Cartilage Regeneration and Joint Preservation Society (ICRS) II and MOCART 3D score for the evaluation of aged osteochondral regenerates in a large animal model, and to identify correlating histological and MRI parameters. Osteochondral defects in medial femoral condyles of n = 12 adult sheep were reconstructed with biodegradable bilayer implants. About 19.5 months postoperation, n = 10 joints were analyzed with MRI (3D MOCART score). Histological samples were analyzed using the ICRS II score; both pre- and post-training. The intraclass correlation coefficient, the inter-rater reliability, and the 95% confidence interval were calculated. Matching histological and MRI parameters were tested for correlation. Results: We found a statistically significant correlation of all histological parameters. MRI parameters reflecting “overall” assessments had very strong inter-rater correlations. Statistically significant strong correlations were found for the MRI parameters defect filling , cartilage interface , bone interface , and surface . For defect overall (MRI) and overall assessment (ICRS II), we found a significant yet mild correlation. Conclusions: The ICRS II and the 3D MOCART score are applicable to aged osteochondral regenerates. Prior training on the scoring systems is essential. Select MRI and histological parameters correlate; however, the only statistically significant correlation was found for overall assessment .


  • Open Access

    Calcar-Guided Short Stems in Total Hip Arthroplasty: A Two-Year Prospective Multicentre Study

    by Hagen Mittelstaedt, Josef Hochreiter, Conrad Anderl, Carsten Johl, Thomas Krüger, Wilmar Hubel, Ulrich Weigert, Jan C. Schagemann

    Background: Calcar-guided short-stem Total Hip Arthroplasty (THA) is increasingly being used to preserve proximal femoral bone stock for potential later revision surgery. Objective: In this study, we aimed to expand the clinical evidence on calcar-guided short-stem THA used in daily clinical practice, focusing on clinical outcomes as well as radiographic signs of stress shielding and femoral bone loss. Methods: In a prospective multicentre study, we enrolled 213 patients with a total of 224 THAs for mainly degenerative indications. The patients were examined clinically and radiographically 6 to 12 weeks, 12 months, and 24 months postoperatively. Results: All clinical outcomes improved significantly over the first 6 to 12 weeks compared to preoperative values (P < 0.001). At 24 months, the mean Harris hip score was 95.3 ± 6.7, and the mean visual analogue scale for pain was 1.0 ± 1.7 under load and 0.5 ± 1.3 at rest. We observed early distal stem migration in six patients and late migration in one patient. Additionally, we found 16 cases of radiographic signs indicative of stress shielding. Four patients required stem revision surgery: two for stem migration, one for periprosthetic fracture, and one for deep infection. Conclusion: Overall, calcar-guided short-stem THA resulted in excellent clinical outcomes after two years of follow-up, and the radiographs revealed few signs of stress shielding. We, therefore, regard calcar-guided short-stem THA as a safe and effective treatment alternative in daily clinical practice.