Purpose: Spoke pulses improve excitation homogeneity in parallel‐transmit MRI. We propose an efficient global optimization algorithm, Bayesian optimization of gradient trajectory (BOGAT), for single‐slice and simultaneous multislice imaging.Theory and Methods: BOGAT adds an outer loop to optimize kT‐space positions. For each position, the RF coefficients are optimized (e.g., with magnitude least squares) and the cost function evaluated. Bayesian optimization progressively estimates the cost function. It automatically chooses the kT‐space positions to sample, to achieve fast convergence, often coming close to the globally optimal spoke positions.We investigated the typical features of spokes cost functions by a grid search with field maps comprising 85 slabs from 14 volunteers.We tested BOGAT in this database, and prospectively in a phantom and in vivo. We compared the vendor‐provided Fourier transform approach with the same magnitude least squares RF optimizer.Results: The cost function is nonconvex and seen empirically to be piecewise smooth with discontinuities where the underlying RF optimum changes sharply. BOGAT converged to within 10% of the global minimum cost within 30 iterations in 93% of slices in our database.BOGAT achieved up to 56% lower flip angle RMS error (RMSE) or 55% lower pulse energy in phantoms versus the Fourier transform approach, and up to 30% lower RMSE and 29% lower energy in vivo with 7.8 s extra computation.Conclusion: BOGAT efficiently estimated near‐global optimum spoke positions for the two‐spoke tests, reducing flip‐angle RMSE and/or pulse energy in a computation time (˜10 s), which is suitable for online optimization.Keywords
Funding Information
- Siemens
- Medical Research Council Canada (MR/M008983/1, N013433‐1)
- Cambridge Trust
- NIHR Cambridge Biomedical Research Centre (BRC‐1215‐20014)
This publication has 30 references indexed in Scilit:
- Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenizationMagnetic Resonance in Medicine, 2013
- kT‐points: Short three‐dimensional tailored RF pulses for flip‐angle homogenization over an extended volumeMagnetic Resonance in Medicine, 2011
- Joint design of spoke trajectories and RF pulses for parallel excitationMagnetic Resonance in Medicine, 2010
- Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readoutMagnetic Resonance in Medicine, 2010
- Slice‐selective RF pulses for in vivo B inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16‐element coilMagnetic Resonance in Medicine, 2008
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Joint design of trajectory and RF pulses for parallel excitationMagnetic Resonance in Medicine, 2007
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- Transmit SENSEMagnetic Resonance in Medicine, 2002