Comparison of the ICP OES viewing modes efficiency in the estimation of cadmium (Cd) and lead (Pb) in whole blood samples
Open Access
- 24 June 2022
- journal article
- research article
- Published by Taylor & Francis in Arab Journal of Basic and Applied Sciences
- Vol. 29 (1) , 208-214
Abstract
In forensic toxicology, precise determination of toxic trace metals in biological samples is critical. Inductively coupled plasma optical emission spectrometry (ICP OES), which has a low limit of detection, high sensitivity, accurate testing, and high analytical efficiency, is one of the most widely used techniques for determining the level of toxic trace metals in biological samples. This study aimed to assess the efficiency of ICP-OES in estimating cadmium (Cd) and lead (Pb) in whole blood samples when viewed axially, dual, and radially. All the samples that were analyzed were digested in 1.5 ml HNO3 and 2 ml H2O2. Selectivity, linearity, recovery, limits of detection (LOD), and quantification (LOQ) were used to validate the system. Cd-axial and radial recovery values were between 82–96 and 84–97%, while Pb-axial and radial recovery values were between 85–94 and 83–99%. Dual Cd-axial and radial recovery values were between 80–92 and 82–94%, while dual Pb-axial and radial recovery values were between 77–92 and 75–96%. The results demonstrated that the axillary and radially view is preferable to the dual view when using separate axially and radially view inductively coupled plasmas (ICP). In axillary and radially views, Cd's recovery rates were better than Pb's in the separate mode, but overall they were satisfactory. The recovery values for Cd and Pb in the dual view were acceptable but not sufficient.Keywords
Funding Information
- University of Tabuk
This publication has 22 references indexed in Scilit:
- Efficiency of Extraction of Trace metals from Blood samples using Wet Digestion and Microwave Digestion TechniquesJournal of Applied Sciences and Environmental Management, 2013
- Heavy Metals Determination in Environmental and Biological Samples2010
- Bioanalytical method validation: An updated reviewPharmaceutical Methods, 2010
- Measurement of radial and axial high energy x-ray spectra in electron cyclotron resonance ion source plasmasReview of Scientific Instruments, 2010
- Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometryAnalytica Chimica Acta, 2010
- Determination of cadmium and lead in human biological samples by spectrometric techniques: a reviewEnvironmental Monitoring and Assessment, 2009
- ICP OES Simultaneous Determination of Ca, Cu, Fe, Mg, Mn, Na, and P in Biodiesel by Axial and Radial Inductively Coupled Plasma-Optical Emission SpectrometryAnalytical Letters, 2008
- Matrix effect of aluminium, calcium and magnesium in axially viewing inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 2007
- Validation of new methodsForensic Science International, 2007
- Elemental Analysis of Human Cremains Using ICP‐OES to Classify Legitimate and Contaminated Cremains*Journal of Forensic Sciences, 2006