Hatem Abdel Moniem Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hatem Abdel Moniem Ahmed has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Nada Alhafez
Department of Forensic Sciences, College of Criminal Justice, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia
4 shared publicationsMuhammad Naeem Janjua
Department of Forensic Sciences, College of Criminal Justice, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia
3 shared publicationsAhmed Johar
Naif Arab University for Security Sciences
1 shared publicationAhmed Saad Goher
Department of Forensic Chemistry, College of Forensic Sciences, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia
1 shared publicationAhmed Saad Gouhar
Department of Forensic Sciences, College of Criminal Justice, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia
1 shared publicationAmro Abdullah Ali Marzoog Alzubaidi
Department of Forensic Chemistry, College of Forensic Sciences, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- 11 March 2024
- Published by Taylor & Francis in Bioanalysis
- Vol. 16 (9) , 401-413
GC–MS/MS analysis of synthetic cannabinoids 5F-MDMB-PICA and 5F-CUMYL-PICA in forensic cases
Aim: Validate a method to quantify 1-(5-fluoropentyl)-N-(2-phenylpropan-2-yl)-1H-indole-3-carboxamide (5F-CUMYL-PICA) and methyl 2-[[1-(5-fluoropentyl) indole-3-carbonyl] amino]-3,3-dimethyl-butano...
- 11 March 2024
- Published by Taylor & Francis in Bioanalysis
- Vol. 16 (9) , 401-413
GC–MS/MS analysis of synthetic cannabinoids 5F-MDMB-PICA and 5F-CUMYL-PICA in forensic cases
Aim: Validate a method to quantify 1-(5-fluoropentyl)-N-(2-phenylpropan-2-yl)-1H-indole-3-carboxamide (5F-CUMYL-PICA) and methyl 2-[[1-(5-fluoropentyl) indole-3-carbonyl] amino]-3,3-dimethyl-butano...
- 31 January 2024
- Published by Springer Nature in Food Analytical Methods
- Vol. 17 (4) , 523-533
ICP-OES Method for the Determination of Trace Metals in Nori Seaweed: Application for the Analysis of Different Samples from Different Countries
- 31 January 2024
- Published by Springer Nature in Food Analytical Methods
- Vol. 17 (4) , 523-533
ICP-OES Method for the Determination of Trace Metals in Nori Seaweed: Application for the Analysis of Different Samples from Different Countries
- 27 August 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (10) , 1-13
Estimation of some heavy metals contamination in waste newspapers
Heavy metals in waste newspapers produce varying degrees of contamination concerns during food consumption, and when heavy metals levels exceed the permissible level, they become harmful to human. Different types of waste newspapers were analyzed for As, Cd, Cr, Ni, Pb, Al, and Zn by ICP-OES. The digestion solution included 10 ml of 69% nitric acid and 2 ml of 30% hydrogen peroxide. Based on the results for light fonts, the average content of As, Cd, Cr, Ni, and Pb was 2.8, 1.5, 6.9, 5.6, and 5.0 µg/l, while was 3.4 and 0.18 mg/l for Al, and Zn, respectively. In bold fonts, the content of As, Cd, Cr, Ni, and Pb was 4.9, 2.4, 9.1, 7.9, and 7.0 µg/l, respectively, while Al and Zn were 5.7 mg/l and 0.32 mg/l, respectively. In the pictures, the levels of As, Cd, Cr, Ni, and Pb were 6.1, 2.99, 11.2, 9.4, and 8.99 µg/l, while Al and Zn were 8.2 and 0.39 mg/l, respectively. The results showed that all levels of heavy metals under study were within the specialized global councils’ permitted limits.
- 27 August 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (10) , 1-13
Estimation of some heavy metals contamination in waste newspapers
Heavy metals in waste newspapers produce varying degrees of contamination concerns during food consumption, and when heavy metals levels exceed the permissible level, they become harmful to human. Different types of waste newspapers were analyzed for As, Cd, Cr, Ni, Pb, Al, and Zn by ICP-OES. The digestion solution included 10 ml of 69% nitric acid and 2 ml of 30% hydrogen peroxide. Based on the results for light fonts, the average content of As, Cd, Cr, Ni, and Pb was 2.8, 1.5, 6.9, 5.6, and 5.0 µg/l, while was 3.4 and 0.18 mg/l for Al, and Zn, respectively. In bold fonts, the content of As, Cd, Cr, Ni, and Pb was 4.9, 2.4, 9.1, 7.9, and 7.0 µg/l, respectively, while Al and Zn were 5.7 mg/l and 0.32 mg/l, respectively. In the pictures, the levels of As, Cd, Cr, Ni, and Pb were 6.1, 2.99, 11.2, 9.4, and 8.99 µg/l, while Al and Zn were 8.2 and 0.39 mg/l, respectively. The results showed that all levels of heavy metals under study were within the specialized global councils’ permitted limits.
- 11 August 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (11) , 1-14
Metals determination in the whole blood by ICP-OES: a comparison of two digestion procedures
The anomalous increases or deficits in the human body can be detected by the development of accurate and sensitive methods for metal quantification in low-level concentrations. Two digestion procedures have been tested on whole blood samples for use in inductively coupled plasma optical emission spectrometry trace metal analysis (ICP-OES). The two procedures are, (microwave digestion with nitric acid and hydrogen peroxide), and (simple dilution digestion with nitric acid, N-butanol, and Triton X-100). According to the findings, the overall recoveries of all determining metals for the microwave digestion were in the range of (96%) of the expected levels, whereas for simple dilution digestion they were in the range of (85–88%) of the expected levels. The results showed a significant difference in the recovery ratios in favor of lead (Pd) and cadmium (Cd) between simple dilution and microwave digestion procedures. The findings also show that the content of these metals may be reliably measured using simple dilution and microwave digestion procedures. Abbreviations: ICP-OES: Induction coupled optical emission spectroscopy; LOD: Limit of detection; LOQ: Limit quantification; AAPCC: American Association of Poison Control Centers; NAUSS: Naif Arab University for Security Sciences; %RSD: Relative standard deviation).
- 11 August 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (11) , 1-14
Metals determination in the whole blood by ICP-OES: a comparison of two digestion procedures
The anomalous increases or deficits in the human body can be detected by the development of accurate and sensitive methods for metal quantification in low-level concentrations. Two digestion procedures have been tested on whole blood samples for use in inductively coupled plasma optical emission spectrometry trace metal analysis (ICP-OES). The two procedures are, (microwave digestion with nitric acid and hydrogen peroxide), and (simple dilution digestion with nitric acid, N-butanol, and Triton X-100). According to the findings, the overall recoveries of all determining metals for the microwave digestion were in the range of (96%) of the expected levels, whereas for simple dilution digestion they were in the range of (85–88%) of the expected levels. The results showed a significant difference in the recovery ratios in favor of lead (Pd) and cadmium (Cd) between simple dilution and microwave digestion procedures. The findings also show that the content of these metals may be reliably measured using simple dilution and microwave digestion procedures. Abbreviations: ICP-OES: Induction coupled optical emission spectroscopy; LOD: Limit of detection; LOQ: Limit quantification; AAPCC: American Association of Poison Control Centers; NAUSS: Naif Arab University for Security Sciences; %RSD: Relative standard deviation).
- Open Access
- 24 June 2022
- Published by Taylor & Francis in Arab Journal of Basic and Applied Sciences
- Vol. 29 (1) , 208-214
Comparison of the ICP OES viewing modes efficiency in the estimation of cadmium (Cd) and lead (Pb) in whole blood samples
In forensic toxicology, precise determination of toxic trace metals in biological samples is critical. Inductively coupled plasma optical emission spectrometry (ICP OES), which has a low limit of detection, high sensitivity, accurate testing, and high analytical efficiency, is one of the most widely used techniques for determining the level of toxic trace metals in biological samples. This study aimed to assess the efficiency of ICP-OES in estimating cadmium (Cd) and lead (Pb) in whole blood samples when viewed axially, dual, and radially. All the samples that were analyzed were digested in 1.5 ml HNO3 and 2 ml H2O2. Selectivity, linearity, recovery, limits of detection (LOD), and quantification (LOQ) were used to validate the system. Cd-axial and radial recovery values were between 82–96 and 84–97%, while Pb-axial and radial recovery values were between 85–94 and 83–99%. Dual Cd-axial and radial recovery values were between 80–92 and 82–94%, while dual Pb-axial and radial recovery values were between 77–92 and 75–96%. The results demonstrated that the axillary and radially view is preferable to the dual view when using separate axially and radially view inductively coupled plasmas (ICP). In axillary and radially views, Cd's recovery rates were better than Pb's in the separate mode, but overall they were satisfactory. The recovery values for Cd and Pb in the dual view were acceptable but not sufficient.
- 24 June 2022
- Published by Taylor & Francis in Arab Journal of Basic and Applied Sciences
- Vol. 29 (1) , 208-214
Open AccessComparison of the ICP OES viewing modes efficiency in the estimation of cadmium (Cd) and lead (Pb) in whole blood samples
In forensic toxicology, precise determination of toxic trace metals in biological samples is critical. Inductively coupled plasma optical emission spectrometry (ICP OES), which has a low limit of detection, high sensitivity, accurate testing, and high analytical efficiency, is one of the most widely used techniques for determining the level of toxic trace metals in biological samples. This study aimed to assess the efficiency of ICP-OES in estimating cadmium (Cd) and lead (Pb) in whole blood samples when viewed axially, dual, and radially. All the samples that were analyzed were digested in 1.5 ml HNO3 and 2 ml H2O2. Selectivity, linearity, recovery, limits of detection (LOD), and quantification (LOQ) were used to validate the system. Cd-axial and radial recovery values were between 82–96 and 84–97%, while Pb-axial and radial recovery values were between 85–94 and 83–99%. Dual Cd-axial and radial recovery values were between 80–92 and 82–94%, while dual Pb-axial and radial recovery values were between 77–92 and 75–96%. The results demonstrated that the axillary and radially view is preferable to the dual view when using separate axially and radially view inductively coupled plasmas (ICP). In axillary and radially views, Cd's recovery rates were better than Pb's in the separate mode, but overall they were satisfactory. The recovery values for Cd and Pb in the dual view were acceptable but not sufficient.
- Open Access
- 19 October 2021
- Published by Springer Nature in Research Square
Estimation of Some Trace Metals Contamination in Waste Newspapers
In the current study, different types of waste newspapers in the Middle East and Asia were analyzed qualitatively and quantitatively by Inductively Coupled Plasma and Optical Emission Spectrometry (ICP OES) for trace metals contamination. 11 samples from different newspapers collected by the researchers from local markets were analyzed for arsenic (As), cadmium (Cd), chromium (Cr), nickel (Ni), lead (Pb), aluminum (Al), and zinc (Zn). Trace metals concentrations in the samples were compared with those established by the various specialized councils. Digestion solution for samples digested in this study included 10 ml of 69% nitric acid and 2 ml of 30% hydrogen peroxide. Based on the results for light fonts, the average content of As, Cd, Cr, Ni, and Pb was (2.8, 1.5, 6.9, 5.6, and 5.0 µgL-1), while was (3.4 and 0.18 mgL-1) for Al, and Zn, respectively. In bold fonts, the content of As, Cd, Cr, Ni, and Pb was (4.9, 2.4, 9.1, 7.9, and 7.0 µgL-1, respectively), while Al and Zn were (5.7 mg/l and 0.32 mgL-1) respectively. In the pictures, the levels of As, Cd, Cr, Ni, and Pb were (6.1, 2.99, 11.2, 9.4, and 8.99 µgL-1), while Al and Zn were (8.2, and 0.39 mgL-1), respectively. The results showed that all levels of trace metals under study were within the specialized global councils' permitted limits, but the presence of trace metals in waste newspapers, even within the permitted limits, remains a source of great concern, as exposure to these elements has a significant impact on consumer health.
- 19 October 2021
- Published by Springer Nature in Research Square
Open AccessEstimation of Some Trace Metals Contamination in Waste Newspapers
In the current study, different types of waste newspapers in the Middle East and Asia were analyzed qualitatively and quantitatively by Inductively Coupled Plasma and Optical Emission Spectrometry (ICP OES) for trace metals contamination. 11 samples from different newspapers collected by the researchers from local markets were analyzed for arsenic (As), cadmium (Cd), chromium (Cr), nickel (Ni), lead (Pb), aluminum (Al), and zinc (Zn). Trace metals concentrations in the samples were compared with those established by the various specialized councils. Digestion solution for samples digested in this study included 10 ml of 69% nitric acid and 2 ml of 30% hydrogen peroxide. Based on the results for light fonts, the average content of As, Cd, Cr, Ni, and Pb was (2.8, 1.5, 6.9, 5.6, and 5.0 µgL-1), while was (3.4 and 0.18 mgL-1) for Al, and Zn, respectively. In bold fonts, the content of As, Cd, Cr, Ni, and Pb was (4.9, 2.4, 9.1, 7.9, and 7.0 µgL-1, respectively), while Al and Zn were (5.7 mg/l and 0.32 mgL-1) respectively. In the pictures, the levels of As, Cd, Cr, Ni, and Pb were (6.1, 2.99, 11.2, 9.4, and 8.99 µgL-1), while Al and Zn were (8.2, and 0.39 mgL-1), respectively. The results showed that all levels of trace metals under study were within the specialized global councils' permitted limits, but the presence of trace metals in waste newspapers, even within the permitted limits, remains a source of great concern, as exposure to these elements has a significant impact on consumer health.
- 17 October 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 101 (8) , 1116-1125
Risk assessment of heavy metals content in different hair dyes and their users’ urine samples
Human toxicity of heavy metals is the result of long-term exposure to pollutants found in hair dyes. In this study, levels of lead (Pb), cadmium (Cd), mercury (Hg) and urine were evaluated in various hair dyes products sold in local stores in Riyadh using inductive coupled plasma optical emission spectrometry (ICP-OES) after digestion with a mixture of nitric acid (HNO3), hydrofluoric acid (HF) and hydrogen peroxide (H2O2) for hair dyes, while a mixture of HNO3 and H2O2 was used for urine. The mean concentrations of the selected heavy metals in hair dye ranged (0.0015–0.0035 ppm) from Cd, (0.003–0.014 ppm) from Pb, which were within the permissible international limits, while for Hg (1.1–4.3 ppm) from Hg was higher than the permissible international limits. The mean concentrations of the selected heavy metals in urine ranged (0. 002, 0.011 and 1.3 ppm) from Cd, Pb, and Hg respectively in the urine. However, in the case of urine samples, the average concentration of Pb was higher than the permitted international limits. The current study showed that the use of hair dyes exposes users to low concentrations of toxic heavy metals that can cause potential health damage to users.
- 17 October 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 101 (8) , 1116-1125
Risk assessment of heavy metals content in different hair dyes and their users’ urine samples
Human toxicity of heavy metals is the result of long-term exposure to pollutants found in hair dyes. In this study, levels of lead (Pb), cadmium (Cd), mercury (Hg) and urine were evaluated in various hair dyes products sold in local stores in Riyadh using inductive coupled plasma optical emission spectrometry (ICP-OES) after digestion with a mixture of nitric acid (HNO3), hydrofluoric acid (HF) and hydrogen peroxide (H2O2) for hair dyes, while a mixture of HNO3 and H2O2 was used for urine. The mean concentrations of the selected heavy metals in hair dye ranged (0.0015–0.0035 ppm) from Cd, (0.003–0.014 ppm) from Pb, which were within the permissible international limits, while for Hg (1.1–4.3 ppm) from Hg was higher than the permissible international limits. The mean concentrations of the selected heavy metals in urine ranged (0. 002, 0.011 and 1.3 ppm) from Cd, Pb, and Hg respectively in the urine. However, in the case of urine samples, the average concentration of Pb was higher than the permitted international limits. The current study showed that the use of hair dyes exposes users to low concentrations of toxic heavy metals that can cause potential health damage to users.
- 10 April 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (6) , 1220-1224
Determination of Zinc Phosphide and Related Heavy Metals in Biological Samples: A Case Report
- 10 April 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (6) , 1220-1224
Determination of Zinc Phosphide and Related Heavy Metals in Biological Samples: A Case Report
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (7) , 1441-1446
Determination of Some Heavy Metals in Eye Shadows Cosmetics
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (7) , 1441-1446
Determination of Some Heavy Metals in Eye Shadows Cosmetics