Several prestressing reinforced structures have recently collapsed due to chloride-induced steel corrosion. This study investigates the effect of the corrosion of hot-dip galvanized conventional prestressing steel reinforcement under hydrogen evolution on bond strength in normal-strength concrete. The impact of hydrogen evolution on the porosity of cement paste at the interfacial transition zone (ITZ) is verified through image analysis. The whole surface of prestressing strands is hot-dip galvanized, and their corrosion behavior when embedded in the cement paste is investigated by measuring the time dependence of the open-circuit potential. Concerning the uniformity of the hot-dip galvanized coating and its composition, it is advisable to coat the individual wires of the prestressing reinforcement and subsequently form a strand. It is demonstrated that the corrosion of the coating under the evolution of hydrogen in the cement paste reduces the bond strength of hot-dip galvanized reinforcement in normal-strength concrete. Image analysis after 28 days of cement paste aging indicates insignificant filling of hydrogen-generated pores by zinc corrosion products. Applying an additional surface treatment (topcoat) stable in an alkaline environment is necessary to avoid corrosion of the coating under hydrogen evolution and limit the risk of bond strength reduction.Keywords
Funding Information
- Grantová Agentura České Republiky (24-12783S)
This publication has 69 references indexed in Scilit:
- Influence of surface roughness on the morphology of interfacial layer and on out-burst formation during hot-dip galvanizingSN Applied Sciences, 2020
- Post-collapse analysis of Morandi’s Polcevera viaduct in Genoa ItalyJournal of Civil Structural Health Monitoring, 2019
- Analysis of sliding mechanism of straight steel fibers in concrete and determine the effect of frictionArchives of Civil and Mechanical Engineering, 2017
- Order–disorder structure of the δ1k phase in the Fe–Zn system determined by scanning transmission electron microscopyActa Materialia, 2014
- Effect of Process Variables on the Grain Size and Crystallographic Texture of Hot-Dip Galvanized CoatingsMetallurgical and Materials Transactions A, 2014
- Immobilization of Zn(II) in Portland cement pastesJournal of Thermal Analysis and Calorimetry, 2012
- Investigations on the re‐passivation of carbon steel in chloride containing concrete in consequence of cathodic polarisationMaterials and Corrosion, 2009
- Galvanized steel behaviour in Ca(OH)2 saturated solutions containing SO4 ionsCement and Concrete Research, 1987
- The effects of Cr2O3, Cu(OH)2, ZnO and PbO on the compressive strength and the hydrates of the hardened C3A pasteCement and Concrete Research, 1979
- Steel/mortar interfaces: Microstructural features and mode of failureCement and Concrete Research, 1979