Thomas H. Reilly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas H. Reilly has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bledar Bisha
Department of Animal Science, University of Wyoming
1 shared publication - Charles S. Henry
Colorado State University
1 shared publication - Chloe A. Beardsley
Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA
1 shared publication - Codi Jo Broten
Department of Animal Science, University of Wyoming, Laramie, WY 82071, USA
1 shared publication - John B. Wydallis
Access Sensor Technologies, Fort Collins, CO 80524, USA
1 shared publication - Kai Z. Fuller
Access Sensor Technologies LLC, 320 E. Vine Dr. STE 221, Fort Collins, CO 80524, USA
1 shared publication
Latest Publications
- Open Access
Development and Evaluation of a Paper-Based Microfluidic Device for Detection of Listeria monocytogenes on Food Contact and Non-Food Contact Surfaces
Listeria monocytogenes is the third most deadly foodborne pathogen in the United States. The bacterium is found in soil and water, contaminating raw food products and the processing environment, where it can persist for an extended period. Currently, testing of food contact and non-food contact surfaces is performed using an array of sampling devices and endpoint technologies, offering various levels of sensitivity, cost, user skill, and time to detection. Paper-based microfluidic devices (µPADs) are a rapid detection platform amenable to low-cost, user-friendly, and portable diagnostics. In this study, we developed and evaluated a µPAD platform specific for the colorimetric detection of the Listeria genus following recovery from food contact and non-food contact surfaces. For detection, four colorimetric substrates specific for the detection of β-glucosidase, two broths selective for the detection of Listeria spp., and a nonselective broth were evaluated to facilitate detection of Listeria spp. The limit of detection and time to detection were determined by using pure bacterial cultures. After 8 h enrichment, L. monocytogenes (102 Colony Forming Units (CFU)/coupon) was detected on every surface. After 18 h enrichment, L. monocytogenes (102 CFU/coupon) was detected on all surfaces with all swabbing devices. This study demonstrated the ability of the µPAD-based method to detect potentially stressed cells at low levels of environmental contamination.
Open AccessDevelopment and Evaluation of a Paper-Based Microfluidic Device for Detection of Listeria monocytogenes on Food Contact and Non-Food Contact Surfaces
Listeria monocytogenes is the third most deadly foodborne pathogen in the United States. The bacterium is found in soil and water, contaminating raw food products and the processing environment, where it can persist for an extended period. Currently, testing of food contact and non-food contact surfaces is performed using an array of sampling devices and endpoint technologies, offering various levels of sensitivity, cost, user skill, and time to detection. Paper-based microfluidic devices (µPADs) are a rapid detection platform amenable to low-cost, user-friendly, and portable diagnostics. In this study, we developed and evaluated a µPAD platform specific for the colorimetric detection of the Listeria genus following recovery from food contact and non-food contact surfaces. For detection, four colorimetric substrates specific for the detection of β-glucosidase, two broths selective for the detection of Listeria spp., and a nonselective broth were evaluated to facilitate detection of Listeria spp. The limit of detection and time to detection were determined by using pure bacterial cultures. After 8 h enrichment, L. monocytogenes (102 Colony Forming Units (CFU)/coupon) was detected on every surface. After 18 h enrichment, L. monocytogenes (102 CFU/coupon) was detected on all surfaces with all swabbing devices. This study demonstrated the ability of the µPAD-based method to detect potentially stressed cells at low levels of environmental contamination.
- 6 December 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (24) , 7520-7527
Method for analysis of environmental lead contamination in soils
A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb—well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg−1 or 4000 ppb)—and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.
- 6 December 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (24) , 7520-7527
Method for analysis of environmental lead contamination in soils
A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb—well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg−1 or 4000 ppb)—and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.